1 / 12

Alteration in disc diameter after DSAEK

Alteration in disc diameter after DSAEK. Takefumi YAMAGUCHI, Yoshiyuki SATAKE, Seika DEN, Kenji KONOMI, Jun SHIMAZAKI Tokyo Dental College, Ichikawa General Hospital, Chiba, Japan. The authors have no financial interest. Introduction.

hume
Download Presentation

Alteration in disc diameter after DSAEK

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Alteration in disc diameter after DSAEK Takefumi YAMAGUCHI, Yoshiyuki SATAKE, Seika DEN, Kenji KONOMI, Jun SHIMAZAKI Tokyo Dental College, Ichikawa General Hospital, Chiba, Japan The authors have no financial interest.

  2. Introduction • Descemet’s stripping and automated endothelial keratoplasty (DSAEK) is treatment of first choice for bullous keratopathy. Total number of endothelial cells transplanted is important in maintaining sufficient number of endothelial cells after DSAEK. However, whether larger disc preferable remains unknown. If so, how large a disc can be safely transplanted? Herein we conducted the study on the disc structure after DSAEK. To evaluate alteration in disc diameter and structure after DSAEK. Purpose

  3. Patients This study comprised 15 eyes in 15 patients who underwent DSAEK at Tokyo Dental College Women: 12 eyes; Men: 3 eyes Age +/- SD: 69.3 +/-12.6 years Surgical technique(no. of eyes) DSAEK: 9 DSAEK+PEA+IOL: 5 DSAEK+TS IOL suturing: 1 (TS: transscleral) Disc diameter8 mm: 14 (no. of eyes) 7.75 mm:1 Graft preparation All grafts were imported from Sight Life Eye Bank (Northwest) and prepared using Barron’s corneal punch during surgery. Causes of bullouskeratopathy (no.of eyes) Laser iridotomy: 7 Cataract surgery: 5 Fuchs’endothelial dystrophy: 2 Pseudoexfoliation syndrome: 1

  4. Methods • Data on disc diameter, central graft anterior chamber depth#1 and central and peripheral graft thickness were obtained using anterior segment optical coherence tomography (AS-OCT, CASIA, SS-1000, Tomey, Japan) at 1 and 3 months after DSAEK. • Measurements were performed manually under refractive correction in 4 directions: horizontal, vertical, 45 and 135 degrees. G-ACD GD #1 Graft anterior chamber depth (G-ACD) was defined as distance between apex of posterior surface of graft and line connecting inner graft edges. Where large decentration of graft position was observed, data were excluded from study. GD: Graft diameter, G-ACD: graft anterior chamber

  5. Results Endothelial cell count Visual acuity LogMAR Graft anterior chamber(G-ACD)=1.50±0.19 μm, Central graft thickness (CGT)=121±30.1 μm Peripheral graft thickness(PGT)=235±101 μm, Angle to angle distance (AD)=11.7±0.58 mm

  6. Average disc diameter (mm) • Disc diameter shrank in all 4 directions (mm: no. of eyes out of 11 eyes#1): • 0.10 < : 9 (81%) • 0.25 < : 7 (64%) • 0.40 < : 5 (46%) #1 Number of patients on whom accurate data obtained in all 4 directions with no obstruction by lid or cilia. GD GD: Graft diameter

  7. Effect of graft decentration Possible measurement error caused by decentration from center of graft during measurement. Distance between O and O’: x (mm) Largest amount of graft shrinkage in 4 directions: S (mm) θ = ∠O’OA S is maxim value if θ is 22.5° If S is below 0.10 mm, x >0.12614 mm If S is below 0.25 mm, x > 0.3013 mm If S is below 0.40 mm, x > 0.462751mm (vertical) A (135) C D O’Graft center θ B B’ oo’=x(mm) (horizontal) O:Measurement center In measuring length and width, there is a high possibility that decentration will cause the graft to appear smaller than it actually is. Taking measurements in all four directions lowers the margin of error. C’ D’ A’ (45)

  8. Relation between GD and G-ACD G-ACD GD This result indicates that G-ACD /GD ratio did not change in various eyes after DSAEK, which suggests the posterior surface curvature (flat or steep) did not influence the GD. GD: Graft diameter, G-ACD: graft anterior chamber GD was significantly correlated with G-ACD. (Pearson’s correlation analysis).

  9. Is larger disc preferable? Advantage ・More endothelial cells can be transplanted. Disadvantage ・Possible decrease in endothelial cells due to manipulation of large disc during surgery. However, there are two important PREMISES • ① Graft size does not change after DSAEK. • ② Endothelial cells will distribute equally throughout host and graft surface. ⇒Slightly shrinks

  10. Discussion Endothelial cell loss after DSAEK has been reported to be 20-50%. Area calculated from parameters of model eye Posterior corneal surface(ACD2.8 mm): approx.110 mm2 Posterior surface of disc of 8 mm: approx.55 mm2 Area of posterior corneal surface Surface area S=π(c2+h2), c: radius, h: height, h=r-√r2-c2, r: curvature of posterior corneal surface, r = 6.8 mm Disc diameter (2c)

  11. Discussion If disc shrinks by around 0.25 mm after DSAEK, it might be possible to transplant larger disc or customize disc diameter using preoperative values of AS-OCT such as angle-to-angle distance or anterior chamber depth in each patient. (We call this AS OCT-assisted DSAEK) If endothelial cells distribute equally on host and graft cornea after DSAEK, endothelial cell loss in previous studies can not be explained based on calculation of posterior surface area. It is possible that endothelial cell “privilege” in DSAEK graft prevents equal redistribution of endothelial cells after DSAEK. More comprehensive and long-term evaluation, including central and peripheral endothelial cell counts, graft edge configuration and chromosome assessment in graft and host cornea, will yield invaluable information on this issue.

  12. Conclusion • Disc diameter tended to shrink from 1 month after DSAEK, stabilizing at 3 months. • In some patients, large alteration in disc diameter observed, suggesting larger disc is preferable in some cases. However, postoperative endothelial cell redistribution on host and graft cornea must be evaluated in future.

More Related