BPM DAQ Software Structure. VME. Oscilloscope. Cable Combiner BOX. New BPM DAQ System has been developed by a fast digital oscilloscope (Tektronix DPO7104) All DAQ Systems have been replaced by New Systems Performance of New DAQ System is enough for 50-Hz measurement. Summary.

honora
Download Presentation

Introduction

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. BPM DAQ Software Structure VME Oscilloscope Cable Combiner BOX • New BPM DAQ System has been developed by a fast digital oscilloscope (Tektronix DPO7104) • All DAQ Systems have been replaced by New Systems • Performance of New DAQ System is enough for 50-Hz measurement. Summary Future Issue EPICS Record Design by VDCT • Development of IOC for beam operation • Development of Device Support including all Oscilloscope Functions • Realization of Synchronized Beam Orbit Measurement among all twenty-five DAQ Systems Result of Performance Test Introduction • Waveform acquisition speed of a fast digital oscilloscope was tested. (Remote/ Local test: Software is running on host computer/ oscilloscope) • Both test results is enough for our purpose (50-Hz measurement). • DAQ Rate by EPICS-IOC is also enough fast. • ・KEK Linac is a injector: • KEKB HER 8 Gev e-/ 3.5 Gev e+ • (Continuous injection Mode: CIM) • (2) KEKB LER 3.5 GeV e+ (CIM) • (3) PF 2.5 Gev e- (once/day) => Top-up • (4) PF-AR 3 GeV e- (twice/day) • ・For long-term stable beam operation: • Needs Beam Orbit and Energy Control We use about 100 of non-destructive BPMs for the orbit and energy feedback. ・Fast Beam-Mode Switch for KEKB CIM and PF Top-up => Needs Beam Position Measurement up to 50-Hz Fast BPM DAQ System Using Windows Oscilloscope-based EPICS IOCM. Satoh,T. Suwada, K. FurukawaAccelerator Laboratory, KEK, Oho 1-1, Tsukuba, Ibaraki, 305-0801 JapanJian Wang Department of Modern Physics, Univ. Sci. & Tech. ChinaHefei 230026, ChinaT. Kudou, S. KusanoMitsubishi Electric System & Service Co., Ltd, Tsukuba, Japan Previous BPM DAQ System (1-Hz) New BPM DAQ System (> 50-Hz) Replaced! DAQ Performance by EPICS-IOC

More Related