1 / 6

Nick’s Issue with SW Structures

Nick’s Issue with SW Structures. Note that this is done in the notes on pages 36-37…. Let’s start with the unalienable basics: Some RF power P in is coming from the power source

holden
Download Presentation

Nick’s Issue with SW Structures

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Nick’s Issue with SW Structures Note that this is done in the notes on pages 36-37… Let’s start with the unalienable basics: Some RF power Pin is coming from the power source The electric field associated with the RF power in the waveguide between source and structure can be written as P = κE2 Conservation of energy requires that, in the absence of beam, the incoming power = the sum of outgoing power, power lost into the walls, and time rate of change of stored energy:

  2. I can replace the Pin term with κE2in. Similarly, I can replace Pout with κE2out, where Eout has to be the sum of the reflected and emitted electric fields (by superposition) -- Pout = κ(Ee+ΓEin)2 If the power from the source is now turned, off, we find: No surprises here -- if the RF source is turned off, the time rate of change in stored energy is given by the power into the walls plus the power that “leaks” out of the structure. If we believe that the leakage power is proportional to the stored energy, and we know that the power lost into the walls is proportional to the stored energy; we therefore can see that the wall losses and coupler losses are proportional to each other!

  3. Call the constant of proportionality βc: I can now replace Pc with κEe2/βc. Since Uc = QwPc/ω, I can do additional substitutions and find: Cancellation of the ubiquitous κ yields:

  4. Let’s look a bit more closely at the equation relating the incoming power’s electric field and the emitted electric field: If Γ is real and negative (which, for now, we assert) and Ee is real and positive (which we again assert) then the first term on the RHS starts out large (equal to Γ2Ein2) -- in fact, for Γ = -1+δ almost all of the incoming power reflects off. As the structure “charges up” and Ee grows, the emitted wave interferes destructively with the reflected wave and the power which goes back up the input waveguide goes to zero! At this point all of the power goes into storage or into the walls. Note that it looks like there are 2 degrees of freedom here (Γ and βc). Actually there aren’t: Γ=-1 for βc=0 and Γ=0 for βc=. In other words, Γ is a very insensitive function of βc.

  5. We can put it all together into an expression for the output electric field: If we supply a constant power (or equivalently a constant value of Ein) to a cavity which has βc>1, the output field will fall gradually to zero and then begin to rise again (as the emitted field exceeds the reflected field). At the instant where the emitted field cancels the reflected field, all of the power goes into the cavity. Thus, the key to making a happy SW structure is to compute the accelerating voltage at the moment Eout goes to zero; compute the current for which V(Eout=0)I=Pin-Pc; and supply that exact current at that exact moment. All of the incoming power will go into the wall or the beam, the stored energy will become constant, the voltage will be constant…

  6. If we turn off the beam but keep the RF power turned on, then the emitted power will grow slowly from zero again (just as if the beam had never been turned on -- it resumes the slow growth that it was doing prior to the beam). If however the beam and the input power are turned off simultaneously, then the emitted wave is no longer cancelled by the reflected wave: So the observed reflected power signal = the input power at t=0; it decays to zero, at which time the beam is turned on, and as a result the reflected power signal stays at zero; then when the beam and the RF power are turned off the “reflected” (actually emitted) power jumps up and exponentially damps away to zero again. Two jumps, two gradual decays.

More Related