1 / 1

Beam Test on Astronomical Hard X-ray Polarimeter PoGO

Beam Test on Astronomical Hard X-ray Polarimeter PoGO. Abstract:.

hallie
Download Presentation

Beam Test on Astronomical Hard X-ray Polarimeter PoGO

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Beam Test on Astronomical Hard X-ray Polarimeter PoGO Abstract: We report the result of a beam test on a prototype of Astronomical hard X-ray/soft gamma-ray Polarimeter, PoGO (Polarized Gamma-ray Observer). PoGO is a new balloon-borne instrument to measure the polarization from astrophysical objects in 25-100 keV range with unprecedented sensitivity, and under development by an international collaboration including United States, Japan, Sweden and France. It consists of 200-400 plastic scintillators and utilizes the design of well-type phoswich counter, providing us with a large effective area and an extremely low background. To examine the performance of PoGO to measure the polarization, we conducted a beam test on the prototype at the Advanced Photon Source Facility at Argonne National Laboratory. The detector consists of seven plastic scintillators and was irradiated by polarized synchrotron beam of 60, 73, and 83 keV. We succeeded in obtaining a clear modulation and reproducing data with Geant4 simulation within ~10%.   Concept of PoGO: (c) downward gamma (a) (b) 100mCrab (incident) 100mCrab (detected) air attenuation (4g/cm2) and detector response are taken into account Background due to atmospheric gamma (d) upward gamma Flux (c/s/cm2/keV) energy 100 keV 20 keV PoGO, Polarized Gamma-ray Observer, is a new balloon-borne instrument to measure the polarization from astrophysical objects in hard X-ray/soft gamma-ray band (25-100 keV). It employs the concept of a well-type phoswich counter (Kamae et al. 1992, SPIE, 1734, 2; Kamae et al. 1996, SPIE, 2806, 314) and will achieve the unprecedented low background and high sensitivity. PoGO consists of 200-400 units of plastic scintillators and determines the polarization by measuring the azimuthal angle distribution from Compton scattering. Each units is composed of a hexagonal fast plastic scintillator (detection part), collimators consisting of a slow plastic scintillator and high-Z metal, and a bottom BGO (Fig. a). Dimensions of the slow-scintillator collimator are ~2.68 cm wide and ~60 cm long, giving a narrow field of view of ~5 deg2. Signals from scintillators are read-out by single photo multiplier tube and interactions in the fast scintillator are distinguished from interactions of others by examining the time development of the signal. These active shields and side anti BGOs reduce the background effectively (Fig b). Expected background level due to atmospheric gamma-rays is ~10mCrab in 40-50 keV, where the effective area is the highest (Fig. c and d). Here, flux models developed through the GLAST Balloon Experiment (e.g., D. J. Thompson et al. 2002, IEEE Trans. Nucl. Sci. 49, 1898) are utilized. For more detail, please refer to the talk by T. Kamae and J. Mitchell. Beam Test at Argonne: To examine the performance of PoGO and validate the Geant4-based Monte-Carlo simulator, we conducted thebeam test at the Advanced Photon Source (APS) Facility of Argonne National Laboratory on November 12-18, 2003. A prototype consisting of 7 fast plastic scintillators and PMTs was used for the test (note that there is no slow scintillators nor BGOs). We irradiated polarized mono-energetic synchrotron beam of 60 keV, 73 keV and 83 keV at the center of the central scintillator (Fig. a). Polarization vector of the beam is along the horizontal axis (x-axis in the photo). y (a) beam direction We measured the polarization by measuring the azimuth-angle asymmetry of the Compton scattering: incident beam is scattered by the central scintillator and photo-aboserbed by one of ring scinrillators. In most of the run, data acquisition was triggered by the coincidence of hits in the central scintillator (Compton scattering threshold level) and any one of ring scintillators (photo-absorption threshold level) to obtain the Compton events efficiently. While processing data, subsequent triggers were inhibited (Fig. b). Shaper outputs of 7 scintillators were digitized and recorded by a waveform analyzer. Fig. c shows a sample of obtained data for 73 keV run. x (b) (c) ch4 (central scintillator), compton scattering ch5 (one of ring scintillators), photo absorption 10us

More Related