Sustained Peaking Capacity Analysis

Sustained Peaking Capacity Analysis. Initiated by the Adequacy Forum Input Information from Utilities Assembled by Don Long. PNW Sustained Hydro Peaking Capacity Analysis. Study Goal:

halia
Download Presentation

Sustained Peaking Capacity Analysis

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Sustained Peaking Capacity Analysis Initiated by the Adequacy Forum Input Information from Utilities Assembled by Don Long Resource Adequacy Steering Committee

  2. PNW Sustained Hydro Peaking Capacity Analysis Study Goal: Perform a “bottom-up” assessment of the sustained peaking capacity of the Pacific Northwest Hydro System over the highest 18 hours in a 3-day cold snap or heat wave under critical, adverse and average water conditions. Study Purposes: Inform Hydro utilities’ resource planning efforts Assure consistent assumptions are used for individual sustained hydro peaking studies, such as assumed flows on common tributaries Provide a check of the GENESYS-based Regional Sustained Hydro Peaking Capability result Help assure consistent reporting of hydro capacity to the Western Electricity Coordinating Council’s Loads and Resources Subcommittee (WECC LRS) and the Pacific Northwest Utilities Conference Committee (PNUCC). Resource Adequacy Steering Committee

  3. Inputs Council provides regional load shape Some utilities chose to model their own hydro generation, submit hourly info for 3-day events: Generation Flow Purchase assumptions Other utilities asked consultant to model for them (utility provides modeling data and purchase assumptions) Consultant also responsible for consistency of assumptions (e.g. upstream discharge is in-line with downstream inflow) Resource Adequacy Steering Committee

  4. Resource Adequacy Steering Committee

  5. Output “Bottom-up” assessment of hydro sustained peak capability for January Cold Spells and July Heat Waves, for 3 water conditions Details of utility study to remain confidential between consultant and utility, other than reporting 1-hour and 18-hour peak capacities. Aggregate purchase assumptions for all utilities will be compared with assumptions used in the PNW Resource Adequacy Standard. Documentation of methodology to allow the analysis to be repeated (at least every 3 years) Resource Adequacy Steering Committee

  6. Status Completed: By utilities: Avista (Clark Fork), EWEB, Federal System (except Elwha River), Idaho Power, PGE, Tacoma By consultant: Avista (Spokane River), Bonners Ferry, City of Centralia, Chelan PUD, Douglas PUD, Energy Northwest, Fall River REA, Grant PUD, Lewis County PUD, Pend Oreille PUD, PPL Montana In progress: By consultant: City of Idaho Falls, City of Portland, Snohomish, Twin Falls Hydro, Warm Springs Tribe Data or studies needed: Utility studies: two missing Data for consultant studies: one still to come Resource Adequacy Steering Committee