1 / 31

2nd level analysis – design matrix, contrasts and inference

2nd level analysis – design matrix, contrasts and inference. Irma Kurniawan MFD Jan 2009. Today’s menu. Fixed, random, mixed effects First to second level analysis Behind button-clicking: Images produced and calculated The buttons and what follows..

groesbeck
Download Presentation

2nd level analysis – design matrix, contrasts and inference

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. 2nd level analysis – design matrix, contrasts and inference Irma KurniawanMFD Jan 2009

  2. Today’s menu • Fixed, random, mixed effects • First to second level analysis • Behind button-clicking: Images produced and calculated • The buttons and what follows.. • Contrast vectors, Levels of inference, Global effects, Small Volume Correction • Summary

  3. Multi-subject Fixed Effect model Subject 1 error df ~ 300 Subject 2 Subject 3 Subject 4 Subject 5 Subject 6 Fixed vs. Random Effects • Subjects can be Fixed or Random variables • If subjects are a Fixed variable in a single design matrix (SPM “sessions”), the error term conflates within- and between-subject variance • But in fMRI (unlike PET) the between-scan variance is normally much smaller than the between-subject variance • If one wishes to make an inference from a subject sample to the population, one needs to treat subjects as a Random variable, and needs a proper mixture of within- and between-subject variance • Mixed models: the experimental factors are fixed but the ‘subject’ factor is random. • In SPM, this is achieved by a two-stage procedure: 1) (Contrasts of) parameters are estimated from a (Fixed Effect) model for each subject 2) Images of these contrasts become the data for a second design matrix (usually simple t-test or ANOVA)

  4. 1st-level (within-subject) 2nd-level (between-subject)  One-sample t-test ^ (1) N=6 subjects (error df =5) ^ b1  ^ (2) ^ b2  contrast images of cbi ^ (3) ^  b3 p < 0.001 (uncorrected)  ^ (4) ^ SPM{t} b4 ^ bpop  ^ (5) ^ b5 WHEN special case of n independent observations per subject: var(bpop) = 2b/ N+2w/ Nn  ^ (6) ^ b6 ^ w= within-subject error Two-stage “Summary Statistic” approach

  5. Contrast 1 Contrast 2 Subject 1 Con image for contrast 1 for subject 1 Con image for contrast 2 for subject 1 You can use checkreg button to display con images of different subjects for 1 contrast and eye-ball if they show similar activations Subject 2 Con image for contrast 1 for subject 2 Con image for contrast 2 for subject 2 Relationship between 1st & 2nd levels • 1st-level analysis: Fit the model for each subject.Typically, one design matrix per subject • Define the effect of interest for each subject with a contrast vector. • The contrast vector produces a contrast image containing the contrast of the parameter estimates at each voxel. • 2nd-level analysis: Feed the contrast images into a GLM that implements a statistical test.

  6. Similarities between 1st & 2nd levels • Both use the GLM model/tests and a similar SPM machinery • Both produce design matrices. • The rows in the design matrices represent observations: • 1st level: Time (condition onsets); within-subject variability • 2nd level: subjects; between-subject variability • The columns represent explanatory variables (EV): • 1st level: All conditions within the experimental design • 2nd level: The specific effects of interest

  7. A1 1 2 3 A2 4 5 6 B1 B2 B3 Similarities between 1st & 2nd levels • The same tests can be used in both levels (but the questions are different) • .Con images: output at 1st level, both input and output at 2nd level • 1st level: variance is within subject, 2nd level: variance is between subject. • There is typically only one 1st-level design matrix per subject, but multiple 2nd level design matrices for the group – one for each statistical test. For example: 2 X 3 design between variable A and B. We’d have three design matrices (entering 3 different sets of con images from 1st level analyses) for • main effect of A • main effect of B • interaction AxB.

  8. Difference from behavioral analysis • The ‘1st level analysis’ typical to behavioural data is relatively simple: • A single number: categorical or frequency • A summary statistic, resulting from a simple model of the data, typically the mean. • SPM 1st level is an extra step in the analysis, which models the response of one subject. The statistic generated (β) then taken forward to the GLM. • This is possible because βs are normally distributed. • A series of 3-D matrices (β values, error terms)

  9. Behind button-clicking… • Which images are produced and calculated when I press ‘run’?

  10. 1st level design matrix: 6 sessions per subject

  11. The following images are created each time an analysis is performed (1st or 2nd level) • beta images (with associated header), images of estimated regression coefficients (parameter estimate). Combined to produce con. images. • mask.img This defines the search space for the statistical analysis. • ResMS.imgAn image of the variance of the error (NB: this image is used to produce spmT images). • RPV.img The estimated resels per voxel (not currently used). • All images can be displayed using check-reg button

  12. 1st-level (within-subject) ^ b1 ^ 1 ^ b2 ^ 2 ^ b3 ^ 3 ^ b4 ^ 4 ^ b5 ^ 5 ^ b6 ^ 6 ^ w= within-subject error Beta images contain values related to size of effect. A given voxel in each beta image will have a value related to the size of effect for that explanatory variable. The ‘goodness of fit’ or error term is contained in the ResMS file and is the same for a given voxel within the design matrix regardless of which beta(s) is/are being used to create a con.img.

  13. Mask.img • Calculated using the intersection of 3 masks: • Implicit (if a zero in any image then masked for all images) default = yes • Thresholding which can be i) none, ii) absolute, iii) relative to global (80%). • Explicit mask (user specified) Explicit masks Group mask Single subject mask Note: You can include explicit mask at 1st- or 2nd-level. If include at 1st-level, the resulting group mask at 2nd-level is the overlapping regions of masks at 1st-levelso, will probably much smaller than single subject masks. Segmentation of structural images

  14. Beta value = % change above global mean. In this design matrix there are 6 repetitions of the condition so these need to be summed. Con. value = summation of all relevant betas.

  15. ResMS.img = residual sum of squares or variance image and is a measure of within-subject error at the 1st level or between-subject error at the 2nd. Con. value is combined with ResMS value at that voxel to produce a T statistic or spm.T.img.

  16. spmT.img Thresholded using the results button.

  17. spmT.img and corresponding spmF.img

  18. So, which images? • beta images contain information about the size of the effect of interest. • Information about the error variance is held in the ResMS.img. • beta images are linearly combined to produce relevant con. images. • The design matrix, contrast, constant and ResMS.img are subjected to matrix multiplication to produce an estimate of the st.dev. associated with each voxel in the con.img. • The spmT.img are derived from this and are thresholded in the results step.

  19. The buttons and what follows.. • Specify 2nd-level • Enter the output dir • Enter con images from each subject as ‘scans’ • PS: Using matlabbatch, you can run several design matrices for different contrasts all at once • Hit ‘run’ • Click ‘estimate’ (may take a little while) • Click ‘results’ (can ‘review’ first before this)

  20. A few additional notes…

  21. How to enter contrasts… E1 E2 R1 Reward R2 Effort Interaction: RE1 x RE2 = (R1E1 – R1E2) – (R2E1– R2E2) = R1E1 – R1E2 – R2E1 + R2E2 = 1 - 1 - 1 + 1 = [ 1 -1 -1 1]

  22. Three levels of inference: extreme voxel values voxel-level (height)inference big suprathreshold clusters cluster-level(extent)inference many suprathreshold clusters set-levelinference voxel-level: P(t  4.37) = .048 n=12 n=82 n=32 cluster-level:P(n  82, t  u) = 0.029 set-level:P(c  3, n  k, t  u) = 0.019 Levels of Inference Set level: At least 3 clusters above threshold Cluster level: At least 2 cluster with at least 82 voxels above threshold Voxel level: at least cluster with unspecified number of voxels above threshold Which is more powerful? Set > cluster > voxel level Can use voxel level threshold for a priori hypotheses about specific voxels.

  23. Example SPM window

  24. global Scaling global Global Effects • May be global variation from scan to scan • Such “global” changes in image intensity confound local / regional changes of experiment • Adjust for global effects (for fMRI) by: Proportional Scaling • Can improve statistics when orthogonal to effects of interest (as here)… • …but can also worsen when effects of interest correlated with global (as next)

  25. Global Effects • Two types of scaling: Grand Mean scaling and Global scaling • Grand Mean scaling is automatic, global scaling is optional • Grand Mean scales by 100/mean over all voxels and ALL scans (i.e, single number per session) • Global scaling scales by 100/mean over all voxels for EACH scan (i.e, a different scaling factor every scan) • Problem with global scaling is that TRUE global is not (normally) known… • …we only estimate it by the mean over voxels • So if there is a large signal change over many voxels, the global estimate will be confounded by local changes • This can produce artifactual deactivations in other regions after global scaling • Since most sources of global variability in fMRI are low frequency (drift), high-pass filtering may be sufficient, and many people to not use global scaling

  26. If have an a priori region of interest, no need to correct for whole-brain! But can correct for a Small Volume (SVC) Volume can be based on: An anatomically-defined region A geometric approximation to the above (eg rhomboid/sphere) A functionally-defined mask (based on an ORTHOGONAL contrast!) Extent of correction can be APPROXIMATED by a Bonferonni correction for the number of resels…(cf. Random Field Theory slides) ..but correction also depends on shape (surface area) as well as size (volume) of region (may want to smooth volume if rough) Small-volume correction

  27. Example SPM window

  28. SVC summary • p value associated with t and Z scores is dependent on 2 parameters: • Degrees of freedom. • How you choose to correct for multiple comparisons.

  29. Statistical inference: imaging vs. behavioural data • Inference of imaging data uses some of the same statistical tests as used for analysis of behavioral data: • t-tests, • ANOVA • The effect of covariates for the study of individual-differences • Some tests are more typical in imaging: • Conjunction analysis • Multiple comparisons poses a greater problem in imaging (RFT; small volume correction)

  30. With help from … • Rik Henson’s slides. • Debbie Talmi & Sarah White’s slides • Alex Leff’s slides • SPM manual (D:\spm5\man). • Human Brain Function book • Guillaume Flandin & Geoffrey Tan