Controller Design Based on Transient Response Criteria

Controller Design Based on Transient Response Criteria. Chapter 12. Desirable Controller Features 1. Quick responding 2. Adequate disturbance rejection 3. Insensitive to model, measurement errors 4. Avoids excessive controller action 5. Suitable over a wide range of operating conditions

Download Presentation

Controller Design Based on Transient Response Criteria

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Controller Design Based on Transient Response Criteria Chapter 12

  2. Desirable Controller Features 1. Quick responding 2. Adequate disturbance rejection 3. Insensitive to model, measurement errors 4. Avoids excessive controller action 5. Suitable over a wide range of operating conditions Impossible to satisfy all 5 unless self-tuning. Use “optimum sloppiness" Chapter 12

  3. Chapter 12

  4. Chapter 12

  5. Chapter 12

  6. Alternatives for Controller Design 1.Tuning correlations - limited to 1st order plus dead time 2.Closed-loop transfer function - analysis of stability ("root locus" - does not include quality of control) 3.Repetitive simulation (requires computer software like MATLAB and Simulink) 4.Frequency response - stability and performance (requires computer simulation and graphics) 5.On-line controller cycling (field tuning) Chapter 12

  7. Controller Synthesis - Time Domain Frequency domain techniques will be discussed in a later lecture. Time-domain techniques can be classified into two groups: (a) Criteria based on a few points in the response (b) Criteria based on the entire response, or integral criteria Approach (a): settling time, % overshoot, rise time, decay ratio (Fig. 5.10 can be viewed as closed-loop response) Chapter 12 Process model Several methods based on 1/4 decay ratio have been proposed: Cohen-Coon, Ziegler-Nichols

  8. Chapter 12

  9. Chapter 12

  10. Chapter 12

  11. Approach (b) 1. Integral of square error (ISE) 2. Integral of absolute value of error (IAE) 3. Time-weighted IAE Pick controller parameters to minimize integral. IAE allows larger deviation than ISE (smaller overshoots) ISE longer settling time ITAE weights errors occurring later more heavily Approximate optimum tuning parameters are correlated with K, ,  (Table 12.3). Chapter 12

  12. Chapter 12

  13. Chapter 12

  14. Summary of Tuning Relationships • 1. KCis inversely proportional to KPKVKM . • 2. KC decreases as / increases. • 3. I and D increase as / increases (typically D = 0.25 I ). • 4. Reduce Kc, when adding more integral action; increase Kc, when adding derivative action • 5. To reduce oscillation, decrease KC and increase I . Chapter 12

  15. Disadvantages of Tuning Correlations 1. Stability margin is not quantized. 2. Control laws can be vendor - specific. 3. First order + time delay model can be inaccurate. 4. Kp, t, and θcan vary. 5. Resolution, measurement errors decrease stability margins. 6. ¼ decay ratio not conservative standard (too oscillatory). Chapter 12

  16. Chapter 12

  17. Direct Synthesis ( G includes Gm, Gv) 1. Specify closed-loop response (transfer function) Chapter 12 2. Need process model, G (= GPGMGV) 3. Solve for Gc,

  18. Example: Second Order Process with PI Controller Chapter 12 PI: or Let tI = t1, where t1 > t2 Canceling terms, Check gain (s = 0)

  19. 2nd order response with... and Select Kc to give (overshoot) Chapter 12 Specify Closed – Loop Transfer Function (first – order response, no offset)

  20. PID Controller for FOPTD Process: let (12-3b) Chapter 12

  21. First-Order-plus-Time-Delay (FOPTD) Model Consider the standard first-order-plus-time-delay model, Substituting Eq. 12-10 into Eq. 12-9 and rearranging gives a PI controller, with the following controller settings: Chapter 12 Second-Order-plus-Time-Delay (SOPTD) Model Consider a second-order-plus-time-delay model,

  22. Substitution into Eq. 12-9 and rearrangement gives a PID controller in parallel form, where Chapter 12 Example 12.1 Use the DS design method to calculate PID controller settings for the process:

  23. Consider three values of the desired closed-loop time constant: . Evaluate the controllers for unit step changes in both the set point and the disturbance, assuming that Gd = G. Repeat the evaluation for two cases: • The process model is perfect ( = G). • The model gain is = 0.9, instead of the actual value, K = 2. Thus, Chapter 12 The controller settings for this example are:

  24. The values of Kc decrease as increases, but the values of and do not change, as indicated by Eq. 12-14. Chapter 12 Figure 12.3 Simulation results for Example 12.1 (a): correct model gain.

  25. Chapter 12

  26. Several IMC guidelines for have been published for the model in Eq. 12-10: • > 0.8 and (Rivera et al., 1986) • (Chien and Fruehauf, 1990) • (Skogestad, 2003) Chapter 12 Controller Tuning Relations In the last section, we have seen that model-based design methods such as DS and IMC produce PI or PID controllers for certain classes of process models. IMC Tuning Relations The IMC method can be used to derive PID controller settings for a variety of transfer function models.

  27. Chapter 12

  28. Tuning for Lag-Dominant Models • First- or second-order models with relatively small time delays are referred to as lag-dominant models. • The IMC and DS methods provide satisfactory set-point responses, but very slow disturbance responses, because the value of is very large. • Fortunately, this problem can be solved in three different ways. • Method 1: Integrator Approximation Chapter 12 • Then can use the IMC tuning rules (Rule M or N) to specify the controller settings.

  29. Method 2. Limit the Value of tI • For lag-dominant models, the standard IMC controllers for first-order and second-order models provide sluggish disturbance responses because is very large. • For example, controller G in Table 12.1 has where is very large. • As a remedy, Skogestad (2003) has proposed limiting the value of : Chapter 12 where t1 is the largest time constant (if there are two). Method 3. Design the Controller for Disturbances, Rather Set-point Changes • The desired CLTF is expressed in terms of (Y/D)des, rather than (Y/Ysp)des • Reference: Chen & Seborg (2002)

  30. Example 12.4 Consider a lag-dominant model with Chapter 12 Design four PI controllers: • IMC • IMC based on the integrator approximation in Eq. 12-33 • IMC with Skogestad’s modification (Eq. 12-34) • Direct Synthesis method for disturbance rejection (Chen and Seborg, 2002): The controller settings are Kc = 0.551 and

  31. Evaluate the four controllers by comparing their performance for unit step changes in both set point and disturbance. Assume that the model is perfect and that Gd(s) = G(s). Solution The PI controller settings are: Chapter 12

  32. Figure 12.8. Comparison of set-point responses (top) and disturbance responses (bottom) for Example 12.4. The responses for the Chen and Seborg and integrator approximation methods are essentially identical. Chapter 12

  33. On-Line Controller Tuning • Controller tuning inevitably involves a tradeoff between performance and robustness. • Controller settings do not have to be precisely determined. In general, a small change in a controller setting from its best value (for example, ±10%) has little effect on closed-loop responses. • For most plants, it is not feasible to manually tune each controller. Tuning is usually done by a control specialist (engineer or technician) or by a plant operator. Because each person is typically responsible for 300 to 1000 control loops, it is not feasible to tune every controller. • Diagnostic techniques for monitoring control system performance are available. Chapter 12

  34. Controller Tuning and Troubleshooting Control Loops Chapter 12

  35. Ziegler-Nichols Rules: These well-known tuning rules were published by Z-N in 1942: Chapter 12 Z-N controller settings are widely considered to be an "industry standard". Z-N settings were developed to provide 1/4 decay ratio -- too oscillatory?

  36. Modified Z-N settings for PID control Chapter 12

  37. Chapter 12

  38. Chapter 12

  39. Chapter 12

  40. Chapter 12 Figure 12.15 Typical process reaction curves: (a) non-self-regulating process, (b) self-regulating process.

  41. Chapter 12 Figure 12.16 Process reaction curve for Example 12.8.

  42. Chapter 12 Figure 12.17 Block diagram for Example 12.8.

  43. Chapter 12 Previous chapter Next chapter