DB-driven Scan-back with collar Nikon dry obj

DB-driven Scan-back with collar Nikon dry obj. Scan back with a NIKON dry objective (collar correction). Nikon ELWD PlanFluor magnification: 40x (nominal) numerical aperture: 0.60 working distance: 1.8 mm correction range: 0-2 mm Similar to the Zeiss already tested but…

finley
Download Presentation

DB-driven Scan-back with collar Nikon dry obj

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. DB-driven Scan-back with collar Nikon dry obj

  2. Scan back with a NIKON dry objective (collar correction) • Nikon ELWD PlanFluor magnification: 40x (nominal) numerical aperture: 0.60 working distance: 1.8 mm correction range: 0-2 mm Similar to the Zeiss already tested but… - The magnification dependency on the correction is lower • The focal plane vertical position dependency on the correction is larger (~ 40 µm). The DC motor, drive belt and serial motor controller used for Zeidd have been mounted in a Nikon microscope. Working conditions: two collar position c.c. 0.0 for the TOP scanning c.c. 0.3 for the BOTTOM scanning

  3. Further improvements and new problems SOFTWAREVERTIGO SCAN 4 (collar correction version) has been further upgraded to take into account also the focal plane shift along the vertical axis due to the correction (~ 40 µm). This effect behaves as a large base shrinkage during the top-bottom linking with the DB-driven processing tools. The exact value of the shift is difficult to be evaluated directly, and has been tuned during the scan back. MECHANICSSome problems occurred during the scan back: • The objective holder (revolver) was not stable when the collar position changes ( little horizontal shift of the bottom field of view). It has been finally blocked with a clamp • Furthermore, sometimes the objective has been found unscrewed. • These problems suggest to substitute the revolver with a more stable single objective holder.

  4. Comparison with previous scan backs: PASSING-THROUGH • Scan back performed on • MIC1 : Zeiss dry microscope • MIC2 : oil microscope • MIC3 : oil microscope • MIC4 : Nikon dry microscope with the same intercalibration, tolerances and drivers • Out of 325 predictions … P = passing throughX = stopping • FAKE STOPPING (± 2 %) : • MIC1 : 24 / 271 ( 9 % ) • MIC2 : 17 / 271 ( 6 % ) • MIC3 : 20 / 271 ( 7 % ) • MIC4 : 27 / 271 (10 % ) • Normalized only with respect to the passing-through sample

  5. MIC3 scan back results: MIC4 scan back results:

  6. Event classification: Event classification:

  7. Conclusions • A scan back with a collar correction nikon dry objective has been performed. • The preliminary results are comparable with the previous scan back obtained with oil obj. • The number of “fake” stopping points is a bit larger (15% instead of 11%) mostly due to the larger background. • The scan back should will be repeated soon in more stable mechanical conditions.