1 / 31

Engine Nacelle Halon Replacement, FAA, WJ Hughes Technical Center

International Aircraft Systems Fire Protection Working Group Atlantic City, NJ USA 30-31 October 2002. Federal Aviation Administration WJ Hughes Technical Center, Fire Safety Section, AAR-440 Atlantic City Int'l Airport, NJ 08405 USA.

fay
Download Presentation

Engine Nacelle Halon Replacement, FAA, WJ Hughes Technical Center

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. International Aircraft Systems Fire Protection Working Group Atlantic City, NJ USA 30-31 October 2002 Federal Aviation Administration WJ Hughes Technical Center, Fire Safety Section, AAR-440 Atlantic City Int'l Airport, NJ 08405 USA Engine Nacelle Halon Replacement,FAA, WJ Hughes Technical Center Point of Contact : Doug Ingerson Department of Transportation Federal Aviation Administration WJ Hughes Technical Center Fire Safety Branch, AAR-440 Bldg 205 Atlantic City Int'l Airport, NJ 08405 USA tel: 609-485-4945 fax: 609-485-7074 email: Douglas.A.Ingerson@faa.gov web page: http://www.fire.tc.faa.gov/

  2. International Aircraft Systems Fire Protection Working Group Atlantic City, NJ USA 30-31 October 2002 Federal Aviation Administration WJ Hughes Technical Center, Fire Safety Section, AAR-440 Atlantic City Int'l Airport, NJ 08405 USA Major Topics for Review : brief overview revision to minimum performance standard for engine/apu (mpse) foundation test plans and results near term plans

  3. International Aircraft Systems Fire Protection Working Group Atlantic City, NJ USA 30-31 October 2002 Federal Aviation Administration WJ Hughes Technical Center, Fire Safety Section, AAR-440 Atlantic City Int'l Airport, NJ 08405 USA • BRIEF OVERVIEW • April - July 2002, Testing • Encountered difficulty with hot surface ignition (HSI) during initial MPSE tests • Ran series of tests and observed HSI behavior - determined phenomena is unreliable • Reviewed a sample of reported HSI behaviors • Results indicated current version of the MPSE was faulted by HSI unreliability • Ran 100+ plus tests to find a way to circumvent HSI unreliability • 23 & 24 July 2002, Task Group Meeting • Convened and discussed issues involving MPSE and HSI • Agreed MPSE required revision • Conceived method to track Halon 1301 suppression performance using HSI reliably • Formulated rough revision of MPSE (revision 3) • Planned foundation testing to resolve potentially complicating issues • August 2002 - Present • Produced a crude flowchart of MPSE revision 3 • Partially completed the foundation testing

  4. International Aircraft Systems Fire Protection Working Group Atlantic City, NJ USA 30-31 October 2002 Federal Aviation Administration WJ Hughes Technical Center, Fire Safety Section, AAR-440 Atlantic City Int'l Airport, NJ 08405 USA • REVISION OF THE MPSE • Evaluating the Basis for the Agent Comparison in the MPSE • MPSE process will have error in results due to environmental behaviors observed to date - conservatism is required, yet error must be minimized where possible • Experienced/reported difficulty with reliable HSI behavior would lead to greater expected error in final results • Equivalence method must represent the associated application in a reliable manner • Equivalence method relies on the occurrence of HSI as it is a threat in this application • Testing during : • April - June 2002; the continually operating electrodes (COE) or a tube array of particular geometry reliably reignited JP-8 • June - July 2002; primary ignition difficulty with low volatility fuel (oil) in the spray fire scenario - suspected impact on HSI behavior using the COE alone • July - August 2002; a combination of the COE and the tube array provided reliable HSI behavior for any fuel type evaluated

  5. International Aircraft Systems Fire Protection Working Group Atlantic City, NJ USA 30-31 October 2002 Federal Aviation Administration WJ Hughes Technical Center, Fire Safety Section, AAR-440 Atlantic City Int'l Airport, NJ 08405 USA • REVISION OF THE MPSE • The Significant Change to the MPSE • Former version of the MPSE • reliance upon the definition of a “robust” fire • equivalence process required finding a minimum of 3 robust fires • the robust fire was a mixture of test conditions that would be extinguished by Halon 1301 for a portion of a fixed number of duplicate tests (80-90%) • a successful quantity of the replacement candidate was to repeat Halon 1301 behavior against the same conditions • HSI in this geometry is an imprecise behavior and was “buried” in the robust fire • Version 3 of the MPSE • robust fire eliminated • changed performance measure to “Reignition Time Delay” - the time between fire extinguishment and reignition which is based on a video review of the test • “Reignition Time Delay” (RTD) is based on a minimum of 5 tests at like condition • a successful quantity of a replacement candidate will be required to repeat or exceed the RTD for Halon 1301 at the same test conditions • HSI is provided for with intentional secondary ignition sources

  6. International Aircraft Systems Fire Protection Working Group Atlantic City, NJ USA 30-31 October 2002 Federal Aviation Administration WJ Hughes Technical Center, Fire Safety Section, AAR-440 Atlantic City Int'l Airport, NJ 08405 USA • REVISION OF THE MPSE • Items of Concern for MPSE revision 3 • Concerns are included for consideration in MPSE revision 3 to improve on the body of work to date • Concerns are reasoned as impacts on the credibility of the final results • compartment ventilation conditions • agent storage, release, and distribution • sufficient severity of the fire threat • variation in the RTD must be observed and understood • Concerns will be addressed with foundation testing and review of others’ work • Retain portions of previous MPSE revision to minimize loss of time

  7. REVISION OF THE MPSE • Spray Fire Zone Configuration, MPSE revision 3 TUBE ARRAY CORE Section A-A FUEL NOZZLES 2” TALL FLAME STABILIZATION RIB AIRFLOW Section A-A SURFACE TEMPERATURE MEASUREMENT POINT AIRFLOW UP UP FWD FWD International Aircraft Systems Fire Protection Working Group Atlantic City, NJ USA 30-31 October 2002 Federal Aviation Administration WJ Hughes Technical Center, Fire Safety Section, AAR-440 Atlantic City Int'l Airport, NJ 08405 USA

  8. UP FWD AIRFLOW International Aircraft Systems Fire Protection Working Group Atlantic City, NJ USA 30-31 October 2002 Federal Aviation Administration WJ Hughes Technical Center, Fire Safety Section, AAR-440 Atlantic City Int'l Airport, NJ 08405 USA • REVISION OF THE MPSE • Spray Fire Zone Configuration, MPSE revision 3 ELECTRODES CORE TUBE ARRAY FUEL NOZZLES 2” TALL FLAME STABILIZATION RIB sta 502 sta 510

  9. International Aircraft Systems Fire Protection Working Group Atlantic City, NJ USA 30-31 October 2002 Federal Aviation Administration WJ Hughes Technical Center, Fire Safety Section, AAR-440 Atlantic City Int'l Airport, NJ 08405 USA • REVISION OF THE MPSE • Process Overview • Parameter for comparing agent suppression performances is RTD; not robust fire • RTD is the duration of time between fire extinguishment and reignition • RTD requires a test fixture which includes RELIABLE secondary ignition sources • Primarily, a single RTD will represent a group of duplicate agent suppression tests • Basis for success : RTD Halon 1301 RTD Candidate replacement • Testing will account for representative : • ventilation conditions • agent storage and discharge considerations • fuels types in a nacelle/APU • fire scenarios • Process will allow for rational test planning • test against the most challenging condition(s) • run verification tests against conditions not explicitly evaluated • attempting to separate fire suppression and agent distribution performances

  10. REVISION OF THE MPSE • Process Overview (continued) RUN FIRE EXTINGUISHMENT TESTS START SELECT VENTILATION CONDITIONS IN SIMULATOR CALCULATE RTD FOR REPLACEMENT CANDIDATE FIND CERTIFICATION DISTRIBUTION FOR HALON 1301 IN SIMULATOR IS RTD ACCEPTABLE ? CONTINUE NO YES SELECT FIRE CONDITIONS IN SIMULATOR RUN SPECIFIED NUMBER OF FIRE EXTINGUISHMENT TESTS ALTER QUANTITY OF REPLACEMENT CANDIDATE CALCULATE RTD FOR HALON 1301 FIRE EXTINGUISHMENT TESTS CHARACTERIZE DISTRIBUTION OF THE REPLACEMENT CANDIDATE CHANGE TO REPLACEMENT CANDIDATE END International Aircraft Systems Fire Protection Working Group Atlantic City, NJ USA 30-31 October 2002 Federal Aviation Administration WJ Hughes Technical Center, Fire Safety Section, AAR-440 Atlantic City Int'l Airport, NJ 08405 USA

  11. International Aircraft Systems Fire Protection Working Group Atlantic City, NJ USA 30-31 October 2002 Federal Aviation Administration WJ Hughes Technical Center, Fire Safety Section, AAR-440 Atlantic City Int'l Airport, NJ 08405 USA • FOUNDATION TESTING • Test Results - Purpose and General Comments • Testing to : • answer questions conceived during initial discussions of MPSE revision 3 • provide data to observe behaviors and uncover issues not initially recognized • Focused on previously stated concerns • List of issues to be addressed by this testing • verify the fire threats are sufficiently severe • minimize/understand varying RTD behavior • fuel type - observe/compare combustion behaviors • agent discharge - consistent preburn or tube array temperature • material changes in the tube array - determine its life span • explore residual fire scenario - determine : • which fuel types can burn in this configuration • the significance of HSI phenomena • the effect of the orientation of the pan geometry on fire intensity

  12. FOUNDATION TESTING • Test Results (continued) - Spray Fire Zone Orientation AIRFLOW UP STA 518 FWD STA 532 STA 532 STA 527 STA 510 TUBE ARRAY International Aircraft Systems Fire Protection Working Group Atlantic City, NJ USA 30-31 October 2002 Federal Aviation Administration WJ Hughes Technical Center, Fire Safety Section, AAR-440 Atlantic City Int'l Airport, NJ 08405 USA

  13. International Aircraft Systems Fire Protection Working Group Atlantic City, NJ USA 30-31 October 2002 Federal Aviation Administration WJ Hughes Technical Center, Fire Safety Section, AAR-440 Atlantic City Int'l Airport, NJ 08405 USA • FOUNDATION TESTING • Test Results (continued) - Varying RTD/Decision to Release Agent • Run a series of spray fire tests and evaluate resulting RTDs • Purposes : • determine if RTD variation can be better controlled by releasing the agent after : • a consistent preburn duration expires • a consistent temperature in the tube array is attained • use results to refine MPSE version 3 • Current test procedure relies on preburn duration • Control of the test article changed for the trials involving tube array temperature • Conditions : • air flow  2.2 lbm/s @ 100°F • JP-8  0.25 gpm • agent  HFC-125 @ 5.2 lbm • Fixed preburn duration  45 seconds • Fixed tube array temperature  1440°F

  14. International Aircraft Systems Fire Protection Working Group Atlantic City, NJ USA 30-31 October 2002 Federal Aviation Administration WJ Hughes Technical Center, Fire Safety Section, AAR-440 Atlantic City Int'l Airport, NJ 08405 USA • FOUNDATION TESTING • Test Results (continued) - Varying RTD/Fuel-Spray Fire Intensity • Ran spray fire tests and recorded temperature profiles • Purposes : • observe fire behaviors • compare energy signature for each fuel type/ventilation condition • use data in refining MPSE revision 3 • Thermocouples spaced longitudinally in the flame path to provide representative picture of combustion behavior • Each individual test condition was repeated 3 times • Fixture cooled down to near ambient condition between tests • Test conditions : • fuels : JP-8, oil (Mobil Jet Oil II), & hydraulic fluid (Skydrol LD-4) • fuel flow rates : 0.25 gpm +/- 0.03gpm • ventilation conditions : 2.2 lbm/s@100°F & 1.0 lbm/s@300°F • no fire suppression agent released

  15. International Aircraft Systems Fire Protection Working Group Atlantic City, NJ USA 30-31 October 2002 Federal Aviation Administration WJ Hughes Technical Center, Fire Safety Section, AAR-440 Atlantic City Int'l Airport, NJ 08405 USA • FOUNDATION TESTING • Test Results (continued) - Varying RTD/Fuel-Spray Fire Intensity • Created averaged temperature profile from data for each set of 3 tests • 8 thermocouples, sta 453, 4” (102 mm) & 8” (204 mm) above core, 2@01:30, 04:30, 07:30, & 10:30 • 1 thermocouple buried in tube array, approximately sta 510 (“515”), 12:00 • 1 thermocouple mounted on door exterior, sta 514, 11:30 • 2 thermocouples, sta 518, 4” & 8” above core, 12:00 • 4 thermocouples, sta 532, 4” & 8” above core, 2@01:00, 11:00 • 6 thermocouples, sta 551 upper, 4” & 8” above core, 2@01:30, 10:30, 12:00 • Calculated a relative “heat” production reference to compare combustion intensity • calculated areas under the averaged temperature traces from 30 to 80 seconds • summed all areas for thermocouples affected by fire (sta’s 510, 514, 518, 532, 551) • subtracted area for sta 453 thermocouples to remove “heat” present in air stream

  16. International Aircraft Systems Fire Protection Working Group Atlantic City, NJ USA 30-31 October 2002 Federal Aviation Administration WJ Hughes Technical Center, Fire Safety Section, AAR-440 Atlantic City Int'l Airport, NJ 08405 USA • FOUNDATION TESTING • Test Results (continued) - Residual Fire Investigation/Fuel Ignition • Ran pool fire tests and recorded temperature profiles • Purposes • determine which fuels can be ignited in the residual fire scenario • use data to refine MPSE revision 3 • Fixture geometry : • master fuel pan in the simulator filled to make a water bath • smaller stainless steel fuel pan located in the water bath • Test conditions : • fuels : JP-8, oil (Mobil Jet Oil II), & hydraulic fluid (Skydrol LD-4) • fuel quantity : 0.47 gallon (1” deep puddle) in 10.5” x 10.3” x 1.5” deep pan • fuel temperature prior to test : 150°F+ (by thermocouple submerged in fuel) • ignition exposure : 10 - 30 seconds intermittently for 3 minutes • ventilation conditions : 2.2 lbm/s@100°F & 1.0 lbm/s@300°F • no fire suppression agent released

  17. FOUNDATION TESTING • Test Results (continued) - Residual Fire Orientation INSERT FOR FUEL PAN AIRFLOW  STA 527 UP FWD STA 502 These assemblies not present during testing MASTER FUEL PAN CH4 NOZZLE & ELECTRODES (shown out of position) CORE International Aircraft Systems Fire Protection Working Group Atlantic City, NJ USA 30-31 October 2002 Federal Aviation Administration WJ Hughes Technical Center, Fire Safety Section, AAR-440 Atlantic City Int'l Airport, NJ 08405 USA

  18. International Aircraft Systems Fire Protection Working Group Atlantic City, NJ USA 30-31 October 2002 Federal Aviation Administration WJ Hughes Technical Center, Fire Safety Section, AAR-440 Atlantic City Int'l Airport, NJ 08405 USA • FOUNDATION TESTING • Test Results - Conclusions • Fire intensity • clean simulator cross section was an insufficient threat • secondary ignition elements required to maintain sufficient threat • Varying RTD • no significant difference noted between releasing agent based on consistent preburn or tube array temperature • fuel types have varying energy signatures - expect impact on RTD to be noticeable • JP-8 worst case for 2.2 lbm/s air flow@100°F • oil selected as worst case for 1.0 lbm/s air flow@300°F • tube array has a life span of 10 fire tests • variation in environmental conditions observed as a noticeable impact • Residual fire scenario • JP8 was the only fuel ignited - oil and hydraulic fluid were not • remaining tests are incomplete

  19. International Aircraft Systems Fire Protection Working Group Atlantic City, NJ USA 30-31 October 2002 Federal Aviation Administration WJ Hughes Technical Center, Fire Safety Section, AAR-440 Atlantic City Int'l Airport, NJ 08405 USA • NEAR TERM PLANS • Complete foundation testing • Determine the impact/relevance of HSI on the residual fire scenario • Determine the impact of altering the fuel surface geometry in the residual fire scenario on combustion intensity • Ultimately, need to “bench-mark” Halon 1301 in this scenario in some manner • Finalize MPSE revision 3 • Discuss/resolve issues • incorporate results of foundation testing completed to date • agent - storage/distribution criteria • final process - need to methodically evaluate replacement candidates without excessive test counts • Commit process to paper • Complete Testing for the replacement candidates by Jun 2003