TESTS OF VIPS IN SIMULATION, LABORATORY, AND PRACTICE. Georg-Wilhelm Mainka Prof. em. Dr.-Ing. University of Rostock, Germany Heiko Winkler Dipl.-Ing. IAIB Wismar, Germany. 9 th International Vacuum Insulation Symposium

loader
I am the owner, or an agent authorized to act on behalf of the owner, of the copyrighted work described.
capcha
Download Presentation

PowerPoint Slideshow about 'TESTS OF VIPS IN SIMULATION, LABORATORY, AND PRACTICE' - fauna


An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -
Presentation Transcript
tests of vips in simulation laboratory and practice

TESTS OF VIPS IN SIMULATION, LABORATORY, AND PRACTICE

Georg-Wilhelm Mainka Prof. em. Dr.-Ing.

University of Rostock, Germany

Heiko Winkler Dipl.-Ing.

IAIB Wismar, Germany

9th International Vacuum Insulation Symposium

The Royal Institution of GreatBritain London 2009-09-18

Revised Version 2009-09-30

the kindergarten kita plappersnut in wismar
The KindergartenKita „Plappersnut“ in Wismar

before Retrofitting: 2004

prefabConcrete Panels

withceramic Skin

after Retrofitting: 2009

East Gable Facade

 VIP 1

North Facade

West Gable f

Facade

 VIP 2

Inside

Hall

2005: Award of the

Journal „Bauphysik“

TEST OF VIPS IN SIMULATION; LABORATORY, AND PRACTICE IVIS - THE ROYAL INSTITUTE OF GREAT BRITAIN - LONDON 2009-09-18

construction of vip1 and vip2
Construction of VIP1 and VIP2

VIP1: Glass-Ceramic-Sandwich

VIP2: ETICS withVIP-kernel

TEST OF VIPS IN SIMULATION; LABORATORY, AND PRACTICE IVIS - THE ROYAL INSTITUTE OF GREAT BRITAIN - LONDON 2009-09-18

vip1 sandwich with 4 vips inside
VIP1: Sandwich with 4 VIPs inside

Sandwich Element with

unsealedjoints

Southern Half 2005

northern Half 2005

Sandwich Element

Coatedonto the

Anchor plate

The Gap between

oldfacade and Sandwich

was filledwith

Mineral Wool

to avoidConvection

Anchor plate

TEST OF VIPS IN SIMULATION; LABORATORY, AND PRACTICE IVIS - THE ROYAL INSTITUTE OF GREAT BRITAIN - LONDON 2009-09-18

vip1 facade plan nearly ready facade and thermography
VIP1: Facade Plan , nearly ready Facade, and Thermography

Southern Half 2005

TEST OF VIPS IN SIMULATION; LABORATORY, AND PRACTICE IVIS - THE ROYAL INSTITUTE OF GREAT BRITAIN - LONDON 2009-09-18

slide6

VIP1:

Influence of Thermal Bridges (WB)

Estern facadeca. 140 m² (2 gable wallssouth-north)

Sandwich glass/ceramicwithVIP-kernel (ADCO company)

WB 1 = WB 2

Φ‘= U*A + Σψ*l

d = λ/(Φ‘*A)

WB 3

-43%

TEST OF VIPS IN SIMULATION; LABORATORY, AND PRACTICE IVIS - THE ROYAL INSTITUTE OF GREAT BRITAIN - LONDON 2009-09-18

vip1 test in the climate chamber
VIP1: Test in the ClimateChamber

Installing the Facade

into the testframe

Facadeready to be tested

Upper right: GlassSiding on Top of 4 VIPs to observetheirBehaviour

TEST OF VIPS IN SIMULATION; LABORATORY, AND PRACTICE IVIS - THE ROYAL INSTITUTE OF GREAT BRITAIN - LONDON 2009-09-18

vip 1 thermal bridges wb measurement vs calculation
VIP 1: Thermal bridges (wb)Measurement vs Calculation

WB1

WB3

WB3

WB2

IR-Thermography at different Thermal Bridges (WB)

Distribution of Surface-Temperature

At WB3

TEST OF VIPS IN SIMULATION; LABORATORY, AND PRACTICE IVIS - THE ROYAL INSTITUTE OF GREAT BRITAIN - LONDON 2009-09-18

vip1 long term behaviour ventilation
VIP1: Long Term Behaviour Ventilation

Southern Half

northern Half

2005

underConstruction

without

Mineral Fibers

2009

TEST OF VIPS IN SIMULATION; LABORATORY, AND PRACTICE IVIS - THE ROYAL INSTITUTE OF GREAT BRITAIN - LONDON 2009-09-18

vip1 long term behaviour cracks
VIP1: Long Term Behaviour Cracks

southern Half 2009

adhesive Figures added 2007 to hidecracks

new cracksoccured

CRACK

With salty Rims at lower Element Border

Detail

CRACK

CRACK

CRACK

IMPACT

HOLE

CRACK

CRACK

TEST OF VIPS IN SIMULATION; LABORATORY, AND PRACTICE IVIS - THE ROYAL INSTITUTE OF GREAT BRITAIN - LONDON 2009-09-18

vip2 etics with vip kernel
VIP2: ETICS with VIP-Kernel

northern Half 2005

underConstruction

Coating

Elements

Fixing

Joint between Elements

Joints at Surface

TEST OF VIPS IN SIMULATION; LABORATORY, AND PRACTICE IVIS - THE ROYAL INSTITUTE OF GREAT BRITAIN - LONDON 2009-09-18

vip2 facade plan ready facade and thermography
VIP2: Facade Plan , readyFacade, andThermography

southern Half 2005

ready

Detail

ventilated Element

TEST OF VIPS IN SIMULATION; LABORATORY, AND PRACTICE IVIS - THE ROYAL INSTITUTE OF GREAT BRITAIN - LONDON 2009-09-18

vip2 u value
VIP2: U-Value

Long Time Monitoring: Temperatures [°C] and Heat Flux [W/m²]

Measured U (k)-Value: U = 0.19 W/m²K

TEST OF VIPS IN SIMULATION; LABORATORY, AND PRACTICE IVIS - THE ROYAL INSTITUTE OF GREAT BRITAIN - LONDON 2009-09-18

vip2 influence of thermal bridges
VIP2: Influence of Thermal Bridges

Western facadeca. 140 m² (2 gable walls)

ETICS withVIP-kernel (Stocompany)

Φ‘= U*A + Σψ*l

d = λ/(Φ‘*A)

-10%

TEST OF VIPS IN SIMULATION; LABORATORY, AND PRACTICE IVIS - THE ROYAL INSTITUTE OF GREAT BRITAIN - LONDON 2009-09-18

vip2 long term behaviour ventilation
VIP2: Long Term Behaviour Ventilation

2005

Northern Half

Southern Half

2009

TEST OF VIPS IN SIMULATION; LABORATORY, AND PRACTICE IVIS - THE ROYAL INSTITUTE OF GREAT BRITAIN - LONDON 2009-09-18

conclusion vip1
Conclusion: VIP1

+ Easy to handle  structuralglazing

  • High performance for adjustablefixingsystem
  • Avoidventilationbehindpanels (mineralfibers)
  • Reasons for cracks in ceramicplates unknown,

probably to thin (3mm)

  • Surface to sensitive for impacts (Vandalism)
  • Ventilated VIPs: to many
  • Thermal bridges: extraenergyloss 43%

 not yet recommended

to be furtherdeveloped

TEST OF VIPS IN SIMULATION; LABORATORY, AND PRACTICE IVIS - THE ROYAL INSTITUTE OF GREAT BRITAIN - LONDON 2009-09-18

conclusion vip2
Conclusion: VIP2

+ commonETICS-technique

+ VIPprotected

+ Ventilated VIPs: veryfew: < 1%

+ Thermalbridges: extraenergyloss 10%

 recommended

TEST OF VIPS IN SIMULATION; LABORATORY, AND PRACTICE IVIS - THE ROYAL INSTITUTE OF GREAT BRITAIN - LONDON 2009-09-18

slide18
End

Thankyou

verymuch

for your Attention

Georg-Wilhelm Mainka georg-wilhelm.mainka.@uni-rostock.de

Heiko Winklerwinkler@iaib.de

TEST OF VIPS IN SIMULATION; LABORATORY, AND PRACTICE IVIS - THE ROYAL INSTITUTE OF GREAT BRITAIN - LONDON 2009-09-18