Clark-Reliance Simpliport Bicolor Water Gage Glass with 180 º Viewing System 2013

Clark-Reliance Simpliport Bicolor Water Gage Glass with 180 º Viewing System 2013. For Applications Up to 1500 PSIG SG800 Series Up to 2500 PSIG SG700 Series Up to 3000 PSIG SG600 Series Always install Chain (Ref: IOM #E-207). SG700. SG800. Forged Steel Water Gage Valves.

eyad
Download Presentation

Clark-Reliance Simpliport Bicolor Water Gage Glass with 180 º Viewing System 2013

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Clark-Reliance Simpliport Bicolor Water Gage Glass with 180º Viewing System2013

  2. For Applications Up to 1500 PSIG SG800 Series Up to 2500 PSIG SG700 Series Up to 3000 PSIG SG600 Series Always install Chain (Ref: IOM #E-207) SG700 SG800 Forged Steel Water Gage Valves

  3. Ball Check Valves (Reference: “Automatic Shutoff Valves” in the Appendix of the ASME Boiler Code) A-18 in the Appendix of Section 1 defines the design requirements for this User OPTION. Ball Checks are not mandatory. Consider the application, before specifying Water Gage Valves with the Ball Check feature. We suggest them for limited applications. Specifying Ball Checks on Water Gage Valves

  4. Tubular Glass Simpliport (Bi-Color) Flat Glass (Transparent) Prismatic (Reflex) Types of Direct Reading Gages

  5. Verify compliance with ASME Section I requirements Confirm serviceable condition of gage glass Consider viewing orientation of the gage for operator convenience Consider gage design alternatives based on: Viewing distance required Atmosphere (indoor/outdoor/hazardous) Design pressure Water quality Illumination requirements Potential for mirrors to save stair climbing Water Gage Glass Guidelines

  6. Operate on the principle of light refraction Light refracts through water different than steam Displays “Green” to indicate the presence of water and “Red” for steam. Gage must be outfitted with an illuminator in order to be Code Compliant Simpliport Bi-Color Water Gage Glasses

  7. Simpliport Bi-Color Gages Steam shows RED.Water shows GREEN.

  8. P4000 Series to 1500 PSI Featuring: ¾” O. D. plain end stem (Nipple) end Connections Packing nuts containing (2) Spring Washers P4100 Series to 3000 PSI Featuring: Flanged Connections (1/2” 2500# RTJ standard) Expansion Loop Packing Nuts containing (2) Spring Washers Four Standard Viewing Arrangements Simpliport Bi-Color Water Gages • Design Features of the 4000/4100 Series: • - .030 V1 Mica – a thicker shield than most others • No Hot Torque Requirements – a Significant benefit • Lower applied torque on Packing Nuts make repairs • easier with a custom engineered sealing gasket.

  9. Simpliport Models Custom Engineered Sealing Gasket & 30 Mil V1 Mica for Maximum Service Life

  10. Simpliport Models

  11. Single Nut design to retain glass = less fasteners than others = less maintenance time Welded body design permits repairs to individual body sections for a fraction of the cost of a replacement gage. Lighter weight design compared to others. Replacement parts remain available for previous models, and now include the heavier mica shields for longer life Advantages of Simpliport Design

  12. Simpliport 180 Viewing System See our in-plant video at www.simpliport180.com Reference: Simpliport Brochure 2011 AB7.5 for details

  13. Simpliport (Bi-Color) Water Column & Simpliport Gage with Traditional Illuminator Level-Max System Simpliport 180 Viewing System

  14. Simpliport 180 LED IlluminatorFeatures • Long Life LED lights, up to 10 years • No More Red or Green Glass Strips • Retrofit most existing Gages • Reduce Power Consumption by more than 95%, when compared to traditional models • Designed for Ordinary (Indoor & Outdoor) Locations

  15. See our Maintenance Video at www.clark-reliance.com/4000video Ref: Instruction manual #R500.E241-A for P4000/P4100 Series Gages (mfr: 2008 to present) using PW-87B modules For older model Simpliport Gages P3000/P3100 (mfr. from 1962 thru 2007) using PW-24BR modules, see video at www.clark-reliance.com/3000video and instruction manual 539I General Comments for all models: Examine gasket surface, before installing new glass modules Use Glass Bead process to clean packing nut threads Always clean, inspect, and lubricate spring washers & threads in packing nuts, prior to assembly. Simpliport Water Gage Maintenance Video and Instructions

  16. Suggest a Maintenance log for users to record ports that have been serviced. Replace remaining ports, after 30% have been replaced. Red crescent shape in green area below level (meniscus line) generally indicate internal contamination. Illuminator and Hood misalignment may affect image on older models without LED Illumination. Simpliport Water Gages