1 / 17

Installation Guide for AC-1000RF & SA V1.6

Installation Guide for AC-1000RF & SA V1.6. Version Eng1.10 Jul.,25.2012. Union Community Co., Ltd. P - 3 P - 2 P - 1. P - 8 P - 7 P - 6 P - 5 P - 4 P - 3 P - 2 P - 1. 1. External Connectors. Wiegand, RS232 & RS485 Interface. DC Power Input Interface. Data2 (Brown) - 1

emmettpage
Download Presentation

Installation Guide for AC-1000RF & SA V1.6

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Installation Guide for AC-1000RF & SA V1.6 Version Eng1.10 Jul.,25.2012 Union Community Co., Ltd.

  2. P - 3 P - 2 P - 1 P - 8 P - 7 P - 6 P - 5 P - 4 P - 3 P - 2 P - 1 1. External Connectors Wiegand, RS232 & RS485 Interface DC Power Input Interface Data2 (Brown) - 1 Data3 (Red) - 2 Ground (Black) - 3 Wiegand In Data0 (Orange) - 1 Data1 (Yellow) - 2 Ground (Black) - 3 Wiegand Out FGND (Green) - 3 Ground (Black) - 2 +12~+24V (Red) - 1 RS485A (Green) - 1 RS485B (Blue) - 2 Ground (Black) - 3 RS485 ** PIN 1 is N.C RS232_TXD (Violet) - 2 RS232_RXD (Gray) - 3 RS232_GND (Black) - 4 RS232 TCP/IP NetworkInterface(RJ45) Door Lock & Status Input Interface Ground (Black) - 8 Door_Monitor2 (Blue) - 7 Door_Monitor1 (Green) - 6 Door_Monitor0 (Yellow) - 5 Inside_Open (Orange) - 4 Lock Ground (Black) - 3 Door Lock2 (Red) - 2 Door Lock1 (Brown) - 1

  3. 2. Main board feature J120 : RS232 J102 : Wiegand Out J201 : DC Input J301 : LAN Interface SW120 : RS-485 termination resistorON/OFF F201 : Fuse J121 : RS-485 Interface J101 : Wiegand In J151 : Lock Interface SW101: RS232 (TTL/232 level select) Lock Type Select S/W Volume Control Lock Type Select S/W

  4. Special. HiD Module to Wiegand Input interface Wiegand In (J101) Ground (Black) - 3 Data3 (Red) - 2 Data2 (Brown) - 1 Green White Black GND (Black) - 4 NC - 3 NC - 2 5V Vcc (Red) - 1 RED RS232 Debug (J120) *  1 .Insert into the Harness side prior to soldering with 5pcs ready for contraction tube 3pie 10mm. 2 . Connecting with soldering to match the colors as shown in the figure. (Black is connected as Wire 3 ) 3 . The column to shrink to fit the soldering site of contraction Tube after soldering . 4 . Short does not occur to the part to remove the Wire the rest of the iClass, deleted I Taping processing so as not . 5 . When you are finished , open the case of AC1000, to be inserted in each of J101, J120 of Page 3. 6 . After connecting the power Close the Case, you can adjust the settings in the configuration Wiegand IN . * To use the RS232 Cable of Page2, and minus the Violet of Pin 2 When installed toward the Pin1, it is possible to use as a power source . By replacing the orange line in the figure above It is possible to use . * It can be used together HiD Card and Card of the existing AC1000 , the thickness of the product is on Pre-installation check is necessary because it may affect the distance  iClass

  5. 3. Schematic for Door Lock Interface

  6. ON NC Strike 1 2 3 4 5 6 NO/Motor Motor SW153 SW152 Strike/MT Strike/MT AutoDoor AutoDoor SW154 SW151 4. Connecting Dead-Bolt Type Door Lock ( Fail Safe ) 4. 1. Connect with one system & one lock ◈ Lock Type Select Switch 1) SW2 2) SW151~SW154 (-)Black (+)Red - C + ON WnP 1 2 3 4 Door Monitor ◈ Wiring diagram Lock(+) Pin 1 Door Lock1 Door Lock2 Lock Ground Inside_Open Door_Monitor0 Door_Monitor1 Door_Monitor2 Ground (Brown) - 1 (Red) - 2 (Black) - 3 (Orange) - 4 (Yellow) - 5 (Green) - 6 (Blue) - 7 (Black) - 8 Ground (-) Pin 3 Pin 4 Pin 5 Lock(-) Pin 8 Inside Door Open S/W

  7. ON ON NC NC Strike Strike 1 1 2 2 3 3 4 4 5 5 6 6 NO/Motor NO/Motor Motor Motor SW153 SW153 SW152 SW152 Strike/MT Strike/MT Strike/MT Strike/MT AutoDoor AutoDoor AutoDoor AutoDoor SW154 SW154 SW151 SW151 4. Connecting Dead-Bolt Type Door Lock ( Fail Safe ) 4. 2. Connect with two system & one lock ◈ Lock Type Select Switch (-)Black System 1 System 2 (+)Red 1) SW2 2) SW151~SW154 1) SW2 2) SW151~SW154 - C + ON WnP 1 2 3 4 ◈ Wiring diagram Lock (-) Door Monitor Lock (+) Pin3 Pin1 Pin5 Pin1 Pin5 Pin2 Pin8 (Brown) - 1 (Red) - 2 (Black) - 3 (Orange) - 4 (Yellow) - 5 (Green) - 6 (Blue) - 7 (Black) - 8 (Brown) - 1 (Red) - 2 (Black) - 3 (Orange) - 4 (Yellow) - 5 (Green) - 6 (Blue) - 7 (Black) - 8 System 2 System 1

  8. ON NC Strike 1 2 3 4 5 6 NO/Motor Motor SW153 SW152 Strike/MT Strike/MT AutoDoor AutoDoor SW154 SW151 5. Connecting Strike Type Door Lock ( Fail Safe ) 5. 1. Connect with one system & one lock ◈ Lock Type Select Switch 1) SW2 2) SW151~SW154 (-)Black (+)Red Door Monitor ◈ Wiring diagram Lock(+) Pin1 Door Lock1 Door Lock2 Lock Ground Inside_Open Door_Monitor0 Door_Monitor1 Door_Monitor2 Ground (Brown) - 1 (Red) - 2 (Black) - 3 (Orange) - 4 (Yellow) - 5 (Green) - 6 (Blue) - 7 (Black) - 8 Ground Pin 3 Pin 4 Pin 5 Lock(-) Pin 8 Inside Door Open S/W

  9. ON ON NC NC Strike Strike 1 1 2 2 3 3 4 4 5 5 6 6 NO/Motor NO/Motor Motor Motor SW153 SW153 SW152 SW152 Strike/MT Strike/MT Strike/MT Strike/MT AutoDoor AutoDoor AutoDoor AutoDoor SW154 SW154 SW151 SW151 5. Connecting Strike Type Door Lock ( Fail Safe ) 5. 2. Connect with two system & one lock ◈ Lock Type Select Switch System 1 System 2 1) SW2 2) SW151~SW154 1) SW2 2) SW151~SW154 ◈ Wiring diagram Lock (-) Door Monitor Lock (+) Pin1 Pin3 Pin8 Pin5 Pin1 Pin2 Pin5 Pin3 (Brown) - 1 (Red) - 2 (Black) - 3 (Orange) - 4 (Yellow) - 5 (Green) - 6 (Blue) - 7 (Black) - 8 (Brown) - 1 (Red) - 2 (Black) - 3 (Orange) - 4 (Yellow) - 5 (Green) - 6 (Blue) - 7 (Black) - 8 System 2 System 1

  10. ON NC Strike 1 2 3 4 5 6 NO/Motor Motor SW153 SW152 Strike/MT Strike/MT AutoDoor AutoDoor SW154 SW151 6. Connecting Strike Type Door Lock ( Fail Secure ) 6. 1. Connect with one system & one lock ◈ Lock Type Select Switch 1) SW2 2) SW151~SW154 (-)Black (+)Red Door Monitor ◈ Wiring diagram Lock(+) Pin1 Door Lock1 Door Lock2 Lock Ground Inside_Open Door_Monitor0 Door_Monitor1 Door_Monitor2 Ground (Brown) - 1 (Red) - 2 (Black) - 3 (Orange) - 4 (Yellow) - 5 (Green) - 6 (Blue) - 7 (Black) - 8 Ground Pin 3 Pin 4 Pin 5 Lock(-) Pin 8 Inside Door Open S/W

  11. ON ON NC NC Strike Strike 1 1 2 2 3 3 4 4 5 5 6 6 NO/Motor NO/Motor Motor Motor SW153 SW153 SW152 SW152 Strike/MT Strike/MT Strike/MT Strike/MT AutoDoor AutoDoor AutoDoor AutoDoor SW154 SW154 SW151 SW151 6. Connecting Strike Type Door Lock ( Fail Secure ) 6. 2. Connect with two system & one lock ◈ Lock Type Select Switch System 1 System 2 1) SW2 2) SW151~SW154 1) SW2 2) SW151~SW154 ◈ Wiring diagram Lock (-) Door Monitor Lock (+) Pin1 Pin3 Pin5 Pin1 Pin5 Pin3 (Brown) - 1 (Red) - 2 (Black) - 3 (Orange) - 4 (Yellow) - 5 (Green) - 6 (Blue) - 7 (Black) - 8 (Brown) - 1 (Red) - 2 (Black) - 3 (Orange) - 4 (Yellow) - 5 (Green) - 6 (Blue) - 7 (Black) - 8 System 2 System 1

  12. NC Strike ON NO/Motor Motor SW153 SW152 Strike/MT Strike/MT 1 2 3 4 5 6 AutoDoor AutoDoor SW154 SW151 7. Connecting EM Type Door Lock( Fail Safe ) 7. 1. Connect with one system & one lock ◈ Lock Type Select Switch 1) SW2 2) SW151~SW154 Brown (+) Door Monitor ◈ Wiring diagram Lock(+) Pin 1 Pin 1 Door Lock1 Door Lock2 Lock Ground Inside_Open Door_Monitor0 Door_Monitor1 Door_Monitor2 Ground (Brown) - 1 (Red) - 2 (Black) - 3 (Orange) - 4 (Yellow) - 5 (Green) - 6 (Blue) - 7 (Black) - 8 Lock(-) Ground Pin 3 Lock(+) Pin 4 Inside_Open Pin 5 Pin 8 Inside Door Open S/W

  13. 2) SW151~SW154 NC Strike ON NO/Motor Motor SW153 SW152 Strike/MT Strike/MT 1 2 3 4 5 6 AutoDoor AutoDoor SW154 SW151 7. Connecting EM Type Door Lock( Fail Safe ) 7. 2. Connect with one system & two lock ** Use external DC Power Adapter ◈ Lock Type Select Switch Lock 1 1) SW2 - (Black) ◈ Wiring diagram + (Red) (-) Lock(-) 12V 3A Adapter Lock(+) (+) Exit B Door Monitor Input1 GND Pin2 Pin1 Pin4 Pin5 Pin8 (Brown) - 1 (Red) - 2 (Black) - 3 (Orange) - 4 (Yellow) - 5 (Green) - 6 (Blue) - 7 (Black) - 8 Inside Door Open S/W Lock 2

  14. NC Strike ON NO/Motor Motor SW153 SW152 Strike/MT Strike/MT 1 2 3 4 5 6 AutoDoor AutoDoor SW154 SW151 Inside Door Open S/W 8. Connecting Auto Door ( Contact Control ) 8. 1. Connect with two system & one door ◈ Lock Type Select Switch 1) SW2 2) SW151~SW154 Auto Door Motor Auto Door Operating Part Auto-Door Sensor Auto-Door Monitor Sensor Input Line 9P CONN ◈ Wiring diagram Lock 1 Pin 1 Door Lock1 Door Lock2 Lock Ground Inside_Open Door_Monitor0 Door_Monitor1 Door_Monitor2 Ground (Brown) - 1 (Red) - 2 (Black) - 3 (Orange) - 4 (Yellow) - 5 (Green) - 6 (Blue) - 7 (Black) - 8 Lock 2 Pin 2 Lock(+)

  15. ON ON NC NC Strike Strike 1 1 2 2 3 3 4 4 5 5 6 6 NO/Motor NO/Motor Motor Motor SW153 SW153 SW152 SW152 Strike/MT Strike/MT Strike/MT Strike/MT AutoDoor AutoDoor AutoDoor AutoDoor SW154 SW154 SW151 SW151 8. Connecting Auto Door ( Contact Control ) 8. 2. Connect with two system & one door ◈ Lock Type Select Switch System 1 System 2 1) SW2 2) SW151~SW154 1) SW2 2) SW151~SW154 Auto Door Motor Auto Door Operating Part Auto-Door Monitor Sensor Input Line ◈ Wiring diagram 9P CONN Pin1 Pin3 Pin1 Pin2 (Brown) - 1 (Red) - 2 (Black) - 3 (Orange) - 4 (Yellow) - 5 (Green) - 6 (Blue) - 7 (Black) - 8 (Brown) - 1 (Red) - 2 (Black) - 3 (Orange) - 4 (Yellow) - 5 (Green) - 6 (Blue) - 7 (Black) - 8 System 2 System 1

  16. NC Strike ON NO/Motor Motor SW153 SW152 Strike/MT Strike/MT 1 2 3 4 5 6 AutoDoor AutoDoor SW154 SW151 9. Connecting Motor Lock ◈ Lock Type Select Switch 1) SW2 2) SW151~SW154 ◈ Wiring diagram Lock(+) Pin 1 Door Lock1 Door Lock2 Lock Ground Inside_Open Door_Monitor0 Door_Monitor1 Door_Monitor2 Ground (Brown) - 1 (Red) - 2 (Black) - 3 (Orange) - 4 (Yellow) - 5 (Green) - 6 (Blue) - 7 (Black) - 8 Lock(-) Pin 2 Ground Pin 3 Inside Open Pin 4 Door Monitor Pin 5 Open Monitor Pin 6 Close Monitor Pin 7 Pin 8 Inside Door Open S/W

  17. ON NC Strike 1 2 3 4 5 6 NO/Motor Motor SW153 SW152 Strike/MT Strike/MT AutoDoor AutoDoor SW154 SW151 10. Connecting 2 Emergency Lamps ◈ Lock Type Select Switch Emergency Lamp 2 Emergency Lamp 1 1) SW2 2) SW151~SW154 Ground (-) Ground (-) 12 V (+) 12 V (+) ◈ Wiring diagram Pin 1 Door Lock1 Door Lock2 Lock Ground Inside_Open Door_Monitor0 Door_Monitor1 Door_Monitor2 Ground (Brown) - 1 (Red) - 2 (Black) - 3 (Orange) - 4 (Yellow) - 5 (Green) - 6 (Blue) - 7 (Black) - 8 Pin 2 Pin 3 Pin 8

More Related