fresenius medical care peritoneal dialysis connections n.
Download
Skip this Video
Download Presentation
Fresenius Medical Care Peritoneal Dialysis Connections

Loading in 2 Seconds...

play fullscreen
1 / 13

Fresenius Medical Care Peritoneal Dialysis Connections - PowerPoint PPT Presentation


  • 254 Views
  • Uploaded on

Fresenius Medical Care Peritoneal Dialysis Connections. Safe-Lock to stay  safe Connection. Connections using Fresenius Medical Care products.

loader
I am the owner, or an agent authorized to act on behalf of the owner, of the copyrighted work described.
capcha
Download Presentation

PowerPoint Slideshow about 'Fresenius Medical Care Peritoneal Dialysis Connections' - edan-schneider


Download Now An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -
Presentation Transcript
connections using fresenius medical care products
Connections using Fresenius Medical Care products

This inservice is not intended to replace the advice or training from your physician. Refer to the Instructions For Use (IFU) for detailed device description, instructions, contraindications, warnings, and precautions.

Fresenius Medical Care, DEL-CLAMP, Stay●Safe, Safe-Lock, DELFLEX and FREEDOM are trademarks of Fresenius Medical Care Holdings Inc. or its affiliated companies. All other trademarks are the property of their respective owners.

fresenius products
Fresenius Products

Baxter is a trademark of Baxter International Inc. or its affiliates.

Instructions on how to use Baxter products were reproduced from the manufacturer’s literature and were current at the time of print. Instructions are included for the patient's convenience but Fresenius Medical Care North America does not specifically endorse the use of these products or assume any liability related to their use. Should there be any differences between the instructions listed in this manual and the instructions for use provided with the medical devices referenced, the instructions provided with the medical device should be taken as accurate."

connections using fresenius medical care products1
Connections using Fresenius Medical Care products

Note: for clarity the model is shown not wearing personal protective equipment (PPE). Follow your facility’s policies and procedures for use of personal protective equipment.

It is vital to maintain sterility of the connectors during connection procedures.

safe lock systems
Safe-Lock Systems

Please note Safe-Lock systems include:

  • Delflex Premier Plus exchange set
  • Freedom Y-set with snap disconnect
  • All Freedom cycler tubing sets
  • Newton cycler set with safe lock connectors
  • 8 Lead Safe-Lock Manifold set
safe lock connections
Safe-Lock Connections

Catheter adapter on catheter

4 inch convertible extension set

Extension set with roller clamp

Premier transfer set

Patient catheter or extension

tubing segment with Del-clamp

The patient’s Safe-Lock connector or extension set will look like one of the above. These are photos of the patient catheter or catheter extension set with a tubing segment secured with a DEL-CLAMPclamp attached.

safe lock patient to stay safe system
Safe-Lock patient to staysafe system

A staysafe Extension Set with Safe-Lock patient connector will allow the patient with a Fresenius Safe-Lock PD system to use staysafe supplies while in the hospital.

staysafe Extension Set with Safe-Lock patient connector

Safe-Lock PD system

staysafe System

safe lock patient to stay safe system1
Safe-Lock patient to staysafe system

Gather supplies

staysafe Extension Set with Safe-Lock patient connector

12 inches (P/N 050-95001)

or

18 inches (P/N 050-95002)

staysafe supplies for procedure.

safe lock patient to stay safe system2
Safe-Lock patient to staysafe system

Disinfectant chamber

Segment secured with Del-clamp

Remove the tubing segment secured with a DEL-CLAMP clampfrom the patient’s catheter and attach the stay●safe Extension Set. Add povidone – iodine solution to the top of threads in the disinfectant chamber. Proceed with the stay●safe exchange procedure.

discharge instructions for all connections
DISCHARGE INSTRUCTIONSFOR ALL CONNECTIONS
  • The patient should return to his/her home or clinic with the additional extension in place. This practice will allow the patient to return home and resume dialysis without interruption.
  • Instruct the patient to remove any adaptors added to their extension set at the beginning of the next exchange or as directed by the PD clinic nurse.
slide11

Choose the type of catheter or transfer set and the type of system utilized. Look down the column and across the row to the adapter needed. Click on the icon in the box to take you to the procedure

slide12

Please contact your Fresenius Clinical Sales Representative at

1-800-662-1237 if you have questions regarding the use of a Fresenius PD system or adapter.

slide13

CD Available through Customer Service

800-323-5188 (P/N # 100676-01)