EliteConsulting Ltd. Altered Images - Thermal Distortion of an Overhead Projector Ray Ellender
Company • Engineering Consultancy in UK • Office in Northampton • Long-Time Mechanica Users • CEP’s, Structure & Motion • Specialise in Mechanica-based FE and Dynamics Consultancy • General Engineering Problem Solving Design and Project Management • PTC Functional Simulation Resellers • Pro/Mechanica and Pro/E Training
The Problem • New Design of Reflective OHP • Thermal Distortion of Base • Distortion of Image
The Method • Make Simplified Model • Correlate with Test • Understand the Mechanism • Brain Storm a Solution • Short-Term • Long-Term
The Model • Simple Mechanica Model • Deflection Measures
Thermal Analysis • Set Up Temp Loads • (Load as a Function of Coordinates) • Correlate with Measurements • Take Results into Structure
Structural Analysis • Set Up Baseline Analysis • Correlate with Measurements • Review Results
Understand the Problem • Hotter at Top than Bottom • Platten Expands more than ‘Ground’ Level • Therefore Get Bowing of the Base • Takes Arm Support with it
Potential Solutions - 1 • Reduce Temperature • Reduce Heat Input Tried - works • Insulate Base Not very good • Conduct Heat Away Not tried • Change Material – Lower CTE Tried - works • Stiffen Base Didn’t work • Cut out most of Platten Didn’t work
Potential Solutions - 2 • Isolate Arm Base from Platten (Hinge) Didn’t work • Mount Arm to Ali Plate & Control Plate Movement Not good enough • Modify Geometry (Lower Platten) Worked well • Make Lower Plate High CTE Worked • Bond Low CTE to Platten (Bimetallic Strip) Worked too well
SolutionsReduce Temperature • Reduce Temp from 60o to 45o • Improvement As expected
SolutionsReduce CTE • CTE reduced from 10 x 105 (ABS) to 7.3 x 105 (PC/ABS) • Works as expected
Solutions ?‘Hinge’ • Hinge to Isolate Arm Mtg Area • Didn’t Work
Solutions ?Stiffer base - Ali Plate Underneath • 3mm Ali Plate • Deflection Worse • Note Ali : CTE = 2.3 x 105
SolutionsHigh CTE Plate Underneath • PE Plate underneath • CTE = 15 x 105 • Deflection improved, if high enough temp.
Solutions‘Bimetallic Strip’ • 1mm Ali Plate attached to Platten (2.3 x 105 CTE) • Works too well
Solutions ‘Bimetallic Strip’ • Smaller Ali Plate • Bonded to ABS • Not so severe • Next step to Optimise
SolutionsLower Platten Surface • Lower by 15mm • Much Improved • Long Term Solution • To be Optimised
SolutionsLower Platten Surface • Global Sensitivity • 12-17mm Depression Is best • Virtually any amount of depression is good
SolutionsLower Platten Surface • Leave middle of platten undepressed to mount Fresnel lens • Details require further development
Summary • 24 Runs in 3 days • Wide Range of Different Solutions • Thermal Solution often Counter-intuitive • Concept Model enabled Solutions to be found quickly • Short & Long Term Solutions found