NEMA TS 2 Traffic Signal Cabinet Troubleshooting

NEMA TS 2 Traffic Signal Cabinet Troubleshooting. Course Outline. Module 1: Introduction and Course Objectives Module 2: History of NEMA Standard Module 3: NEMA Cabinet Platforms Module 4 : NEMA TS 2 Standard – An Overview

donnawhite
Download Presentation

NEMA TS 2 Traffic Signal Cabinet Troubleshooting

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. NEMA TS 2 Traffic Signal Cabinet Troubleshooting

  2. Course Outline Module 1:Introduction and Course Objectives Module 2:History of NEMA Standard Module 3: NEMA Cabinet Platforms Module 4: NEMA TS 2 Standard – An Overview Module 5:Definitions and Environmental Requirements (Sections 1 and 2) Module 6:Controller Units (Section 3) Module 7:Malfunction Management Unit (Section 4) Module 8: Terminals and Facilities (Section 5)

  3. Course Outline Module 9: Auxiliary Devices (Section 6) Module 10: Cabinets (Section 7) Module 11: Bus Interface Unit (Section 8) Module 12: Surge Protection Module 13: Cabinet Troubleshooting Procedures Module 14: Summary and Questions Module 15: Hands-On

  4. Module 1:introductions and course objectives

  5. Course Learning Objectives • To develop an understanding of the NEMA TS 2 Standards • To develop an understanding of each of the components of a NEMA TS 2 Cabinet Assembly and their respective functionality • To be able to identify the platform of cabinet whether it be NEMA TS 1, NEMA TS 2 Type 1, or NEMA TS 2 Type 2 • To develop an understanding of the process of cabinet troubleshooting

  6. Module 2:History of NEMA Standard

  7. Technology has come a long way!

  8. 1975 2009 N E M A Pre-Standards TS-1 1976 TS-2 1992 Caltrans / NYDOT 1979 170 179 1985 170E 1990 2070 1995 ATC 1999 - Developing Courtesy of Vanasse Hangen Brustlin, Inc. (VHB)

  9. NEMA TS 1 Controller Platform • NEMA TS 1 Adopted in 1976 and reaffirmed in 1989 • Goal of the standard was to provide interchangeability among manufacturers • Functional standard • Included all equipment in the cabinet

  10. NEMA TS-1 Controller PlatformDisadvantages • Standard did not allow for expandability beyond the three connectors defined • MSD (fourth connector) is manufacturer specific and thus prevented interchangeability for enhanced controller functions such as coordination and preemption • Did not cover pretimed operation • Capabilities beyond traffic control not available • System communications not interchangeable

  11. NEMA TS 1 Controller PlatformAdvantages • Defined effective basic actuated intersection control • Allowed for interchangeability among manufacturers for basic functions by defining the A, B, and C Connectors • By not specifying hardware, controller capabilities expanded with technology

  12. NEMA TS-1 Controller Platform With Enhanced Features

  13. NEMA TS-2 Controller Platform • Developed in 1992 and formally approved by NEMA to overcome the limitations of TS 1 • Standard defined two types of controllers • TS2 Type 1 – utilizes high speed serial bus • TS2 Type 2 – retains MS connectors allowing for downward compatibility • Included pretimed control operation and cabinet standards • NEMA TS -2 Reaffirmed in October,1998 and again in May, 2003 to include NTCIP requirements

  14. NEMA TS 2 Objectives • Define equipment requirements based on valid engineering concepts • Allow for Interchangeability without precluding downward compatibility of TS 1 equipment • Develop enhanced diagnostics • Minimize potential malfunctions • Provide for future expandability • Allow for enhanced user interface • Define advanced traffic signal operations such as coordination and preemption • Advanced cabinet monitoring and diagnostics

  15. NEMA TS 2 Standard - Proposals • Standardize the present “D” connector • Free up seldom used pins on MSA, MSB, and MSC connectors and reassign them for enhanced functions • Proceed with an entirely new standard • Proceed with proposal 1 then move to proposal 3 for the long term solution

  16. Results of the NEMA TS 2 Standard Development Process • Decision made to go with Proposal 3, provide for two types of cabinet platforms: • TS2 Type 1 – utilizes high speed serial bus • TS2 Type 2 – retains MS connectors allowing for downward compatibility • Let the end user decide on what platform best meets their short and long term requirements

  17. Module 3:NEMA Cabinet Platforms

  18. DETECTORS CMU A D B C 171 WIRES TERMINAL FACILITIES 81 WIRES TS1 CABINET CONFIGURATION

  19. MMU POWER SUPPLY DETECTOR RACK SDLC 15 WIRES PA P2 P1 P3 ENET A B C 81 WIRES 171 WIRES TERMINAL FACILITIES SDLC 15 WIRES BIU BIU BIU 15 WIRES 15 WIRES TS2 CABINET CONFIGURATION 15 WIRES

  20. Two Types of NEMA TS 2 Controllers PA P2 • TS 2 Type 1 • “Pure” TS 2 Controller • Small MS A connector for Power and Fault Monitor • Communication to cabinet devices via Port 1 SDLC bus • TS 2 Type 2 • Downward compatible to TS 1 • MS A, B, and C connectors plus Port 1 SDLC for communication to MMU PA P1 P2 P3 ENET P1 P3 ENET A B C

  21. MMU POWER SUPPLY DETECTOR RACK PA P2 P1 SDLC P3 ENET 15 WIRES Port 1 SDLC Interface Panel 81 WIRES TERMINAL FACILITIES BIU BIU BIU SDLC 15 WIRES “PURE” TS2 TYPE 1 CABINET CONFIGURATION

  22. “Pure” TS 2 Type 1 Cabinet Configuration • Communication between cabinet equipment accomplished via Synchronous Data Link Control (SDLC) Bus eliminating MS A, B, and C connectors – “SDLC is highway for cabinet communications” • Communication to Terminal Facilities (TF) and Detector Rack via SDLC bus through Bus Interface Units (BIUs) • Malfunction Management Unit (MMU) communicates to controller through SDLC bus and retains discrete point-to-point wiring to TF • Eliminates most point-to-point wiring connections making for less points of failure

  23. MMU POWER SUPPLY DETECTOR RACK PA P2 P1 SDLC P3 ENET 15 WIRES A B C Port 1 SDLC Interface Panel 81 WIRES TERMINAL FACILITIES 171 WIRES BIU HYBRID TS2 TYPE 2 CABINET CONFIGURATION

  24. TS 2 Type 2 Cabinet Configuration • Minimum requirement that the controller and MMU be connected via the Port 1 SDLC bus • Controller has both Port 1 connector to interface with SDLC bus and MS A, B, and C connectors to interface with TF • Type 2 allows for downward compatibility with TS-1 cabinets

  25. Time for a Quiz!

  26. NEMA TS 2 Cabinet Assemblies TS2 Type 1 or TS 2 Type 2 ?

  27. NEMA TS 2 Cabinet Assemblies TS2 Type 1 or TS 2 Type 2 ?

  28. NEMA TS 2 Cabinet Assemblies TS2 Type 1 or TS 2 Type 2 ?

  29. NEMA TS 2 Cabinet Assemblies TS2 Type 1 or TS 2 Type 2 ?

  30. Module 4:NEMA TS 2 Standard – an overview

  31. Benefits of NEMA TS 2 Standard • Enhanced standardization • Enhanced safety & reduced liability • Upgrade path for expansion & innovation • Greater opportunity for multiple sourcing

  32. NEMA TS 2 StandardEnhanced Standardization • TS2 specifies controllers and cabinets more fully than TS1 • Defines advanced functionality such as coordination, preemption, and time base control • Defines detector programming to allow for individual detector channels

  33. NEMA TS 2 StandardEnhanced Standardization • Specifies all connections inside traffic cabinet • Eliminates manufacturer-specific “D” connector • Specifies cabinet dimensions • Type 2 allows for downward compatibility with TS-1 cabinets

  34. NEMA TS 2 StandardEnhanced Safety and Reduced Liability • Simplified cabinet wiring • Redundant MMU functionality • Program verification (Controller and MMU) • Provision for output monitoring • Clearance time monitoring • AC power monitoring • Detector status and failure monitoring • Cabinet-level diagnostics • Enhanced controller logging

  35. NEMA TS 2 StandardEnhanced Safety and Reduced Liability • Simplified Cabinet Wiring • 15 wire SDLC bus replaces 171 wire A, B, and C cables • Redundant MMU Functionality • A TS2 controller can put the intersection into flash if the MMU fails • Program Verification • Controller and MMU verify each others program every 100msec

  36. NEMA TS 2 StandardEnhanced Safety and Reduced Liability • Output Monitoring • The MMU can compare the load switch output to the controller output • Clearance Time Monitoring • The MMU times the interval between conflicting greens and yellow clearance time • AC Power Monitoring • The MMU monitors incoming power for low voltage and brownout conditions

  37. NEMA TS 2 StandardEnhanced Safety and Reduced Liability • Enhanced Controller Logging • Detector Report • Events Report • MMU Report

  38. Upgrade Path for Expansion and Innovation Open architecture at cabinet level • Made possible by SDLC bus • Interface to as yet unspecified cabinet devices Open architecture at system level • Made possible by standardized telemetry port and NTCIP Communications Protocol “Technology platform” for future ITS applications

  39. NEMA TS 2 Standard - Overview • Section 1 – Definitions • Section 2 – Environmental Requirements • Section 3 - Controller Units • Section 4 - Malfunction Management Unit (MMU) • Section 5 - Terminals and Facilities • Section 6 - Auxiliary Devices • Section 7 - Cabinets • Section 8 - Bus Interface Unit (BIU)/Synchronous Data Link Cables (SDLC)

  40. NEMA TS 2 Cabinet Assembly

  41. Module 5:Definitions and environmental requirements (Sections 1 and 2)

  42. Section 1 - Definitions • Includes definition of new devices and functions defined by TS-2 • BIU – Bus Interface Unit • CU – Controller Unit • DR – Detector Rack • MMU – Malfunction Management Unit • TF – Terminals and Facilities • AD-Auxiliary devices • Coordination • Preemption • Time Base Control • Detection

  43. Section 2 – Environmental Requirements • Establishes limits for environmental and operating conditions in which a device will perform. • Defines a series of minimum test procedures to ensure device conformance to the standard. • Endurance tests • Shock tests • Electrical tests

  44. Section 2 – Environmental Requirements • Environmental and Operating Standards • Operating Voltage – 120 VAC • Operating Frequency – 60 Hz +_ 3Hz • Temperature – -34C (-30F) to +74C(+165F) • Humidity – 95 %

  45. Module 6:Controller units(Section 3)

  46. Controller Units • Physical Standards • Interface Standards • Functionality • Modes • Unit Types • NTCIP

  47. Controller Unit Physical Standards - Configurations PA P2 PA P1 P2 P3 ENET P1 P3 ENET A B C TS 2 Type 1 Source : NEMA TS2 - 2003 Standards Publication Section 3.2 TS 2 Type 2

  48. Controller Unit Physical Standards - Configurations • Maximum height = 12” • Maximum width = 19” (allowed for rack mounting) • Maximum depth = 14.5” * * - This dimension includes connectors, harnesses and protrusions.

  49. Controller Unit Interface Standards – Type A1 and P1 • Input/Output (I/O) for CU to MMU/DR/TF/AD is defined under section 3.3.1 • Section 3.3.1 defines the high speed, full duplex communications protocol which links all of the control cabinet assemblies devices.

  50. Controller Unit Interface Standards – Type A2 and P2 • I/O for CU to MMU/DR is defined under section 3.3.1. • I/O for CU to TF/AD and any shelf mounted detectors is defined under section 3.3.5.