1 / 7

CHEN 4470 – Process Design Practice

This lecture discusses the purpose of reboilers, different types of reboilers (thermosyphon, forced circulation, kettle, internal), and the importance of proper reboiler design for column operation. It also includes information on 2-phase flow regions and all-liquid flow regions in reboilers.

deidrem
Download Presentation

CHEN 4470 – Process Design Practice

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Distillation Modeling CHEN 4470 – Process Design Practice Dr. Mario Richard EdenDepartment of Chemical EngineeringAuburn University Lecture No. 13 – Reboiler Selection and Design February 26, 2013 Material Developed by Dr. Jeffrey R. Seay, University of Kentucky - Paducah

  2. Overview • Purpose of Reboilers • Provide vapor flow up a column and acts as an additional theoretical stage below the trays/packing • Types of Reboilers • Thermosyphon • Forced circulation • Kettle • Internal reboiler (rarely used in continuous columns) Proper reboiler design is critical to the optimum operation of a column!

  3. Thermosyphon Reboiler • Return piping to the column must be sized for two-phase flow. • Thermosyphons operate based on thermodynamic principles, rather than gravity. • Therefore, design detail is important. • Thermosyphon operation is simple, but they are often difficult to design for a wide operating range. • Proper elevation is critical! 2-Phase Flow Region All-Liquid Flow Region

  4. Forced Circulation Reboiler • Forced circulation reboilers are designed to operate liquid full. • Flashing occur as the liquid crosses the control valve. • Valve should be located close to the column shell. • Forced circulation reboilers offer greater operational flexibility than thermosyphons, yet have a smaller footprint than kettle reboilers. • Elevation is less critical due to pump and control valve.

  5. Kettle Reboiler • Vapor-Liquid disengagement occurs in the vapor space, therefore return piping is sized for all-vapor flow. • Proper elevation is critical to kettle reboiler operation. • Kettles have a large footprint, but require less elevation than a thermosyphon. • Works by gravity, rather than thermodynamics. Cross Section of Kettle All-Vapor Flow Region All-Liquid Flow Region

  6. Reboiler Design Reboiler Selection Flowchart Cost Comparison of Reboiler Types Thermosyphon Kettle Forced Circulation

  7. Reboilers in ASPEN Plus