Alaska Commercial Energy Audit

Alaska Commercial Energy Audit. Auditors Meeting May 14,2012. Agenda overview. Introductions Energy Efficiency in Alaska Framework Program Overview Program Guidelines Applying Customer Commitments Audit Report Expectations Expectations Reporting Resources Discussion. AEA StafF.

cole-lynn
Download Presentation

Alaska Commercial Energy Audit

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Alaska Commercial Energy Audit Auditors Meeting May 14,2012

  2. Agenda overview • Introductions • Energy Efficiency in Alaska Framework • Program Overview • Program Guidelines • Applying • Customer Commitments • Audit Report Expectations • Expectations • Reporting • Resources • Discussion

  3. AEA StafF energyaudits@aidea.org Rebecca Garrett Project Development Specialist 771-3044 rgarrett@aidea.org Yolanda Inga Administrative Assistant 771-3903 yinga@aidea.org Other Contacts: Sean Skaling Dir. Alternative Energy & Energy Efficiency 771-3079 sskaling@aidea.org Katie Conway Ast. Manager Energy Efficiency & Conserv. 771-3078 kconway@aidea.org

  4. 15% by 2020 • House Bill 306 (2010): “It is the intent of the legislature that the state achieve a 15 percent increase in energy efficiency on a per capita basis between 2010 and 2020.” • State programs to address each sector

  5. Program Overview http://www.akenergyauthority.org/efficiencyaudits.html

  6. Program Guidelines Please refer to Program Guidelines document

  7. Program Guidelines • Application Period Extended • Stimulus Funded • Intent: cover most of audit cost • Quality info to building owners • Measures self-funded by owner • Loans from AK Div. of Economic Development

  8. Important Dates • August 10, 2012: Audit reports complete and received by customer. • August 31, 2012: Reimbursement request deadline

  9. Energy Audit Level • ASHRAE Level II energy audit or better • Customers may specify additional areas for deeper inspection • Customer-oriented approach

  10. Reporting • Auditor responsibility: by 4:30 August 10 • To customer: Audit report, invoice, and supporting documents • To AEA: Audit report, 2012 audit report summary form, and digital utility records to energyaudit@aidea.org • Add measures to AkEnergyEfficiencyMap.org (June1) • Audit reports can be in your own format, but must contain the following elements: • Specify by ECM the estimated dollar investment, energy savings, dollar savings, and payback period (or better) for each recommended measure. • Photos are very helpful to customers • Digital utility bill records: • 2 years+ in Excel, Portfolio Manager, or AkEE Map

  11. reporting • Customer responsibility: by 4:30 August 31, 2012 • Rate auditor online • Submit request for reimbursement form with • Copy of auditor’s invoice • Proof of payment • By August 31, 2013 (1 year later) • Implement ECMs to the extent committed on the application form.

  12. Audit Report Quality • Audit all major building systems • Heating, ventilation, AC • Lighting (indoor, out; controls; light levels; after-hours use) • Electrical equipment (motors, pumps, plug loads, appliances) • Specialized equipment (walk-in freezers, kitchen equipment, etc.) • Domestic hot water • Building envelope • Energy conservation

  13. Audit contents • Check and report on all possible energy savings • After hours use of the building/systems • Energy conservation • Plug loads • Use data loggers or sub-meters whenever possible • Occupancy versus use • Log starts, stops, temperatures, light levels, etc. • Report data log use in white paper if common occurrence

  14. Optional elements • Building modeling (AkWarm Commercial, other) • Sub meters • Indoor air quality • Infrared imagery

  15. Modeling software • AHFC’s AkWarm Commercial • An option, not required • For training, contact James Diemer, jdiemer@ahfc.us

  16. benchmarking • Preferred: Alaska Energy End-Use Study • New data on AEA’s web site akenergyauthority.org • May also use EPA Portfolio Manager’s building rating system or others.

  17. Customer ratings • Customers rate auditors online for public to see • Auditor statements of qualifications • Please include the following: • Home City • Service area • Phone, email, web, physical address • Brief statement of qualification • List special areas of interest • Names of individual auditors • Edit existing pages by emailing new statement to: • info@akenergyefficiency.org

  18. Future Selection of auditors • AEA may use the quality of this year’s energy audits to determine qualification for future years. • Likely to select a smaller pool • May continue to select from the best of the best to encourage continuous improvement • May conduct a 3rd party quality review of auditors and their reports

  19. Equipment

  20. White papers • We welcome white papers on energy efficiency findings • Example 1: Energy savings achieved by use of remotely switched power strips at each workstation • Example 2: Using federal tax incentives to implement energy efficiency measures • 1-page document • Focus on results, good or bad • Can also create a “Story” on the efficiency map

  21. Definition of mechanical ventilation • Additional reimbursement is available for buildings with mechanical ventilation, including: • Full HVAC systems • Mechanical exterior air intake and controls • This does not include buildings with exhaust fans only. • Auditors are responsible for checking that the building correctly specified mechanical ventilation and square footage.

  22. Rural travel stipend • Customers 100 miles or more from an auditor receive an additional $300 for auditor travel, if… • 3 other energy audits in the same community were performed during the same trip

  23. In the Future • Posting of new Audit Summary Report Form • EE Map database to add utility records • Auditor selection • Loans

  24. Energy efficiency Map

  25. Questions? Share your experience Dialogue time…

  26. Questions for you… • What training opportunities would you like to see? • How can we improve the program? Feedback is always welcome.

  27. AEA StafF energyaudits@aidea.org Rebecca Garrett Project Development Specialist 771-3044 rgarrett@aidea.org Yolanda Inga Administrative Assistant 771-3903 yinga@aidea.org Other Contacts: Sean Skaling Dir. Alternative Energy & Energy Efficiency 771-3079 sskaling@aidea.org Katie Conway Ast. Manager Energy Efficiency & Conserv. 771-3078 kconway@aidea.org