An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. NAF Product Training

  2. NAF-eValuate

  3. NAF-eValuateTM • What is NAF-eValuate? • FDT-based software package for configuration and diagnostics • Includes: • PACTwareTM software cd • PACTwareTM user manual • NAF-eValuate Quick guide • NAF-LinkIT DTMs

  4. FDT / DTM NAF-LinkIT fully integrated with FDT / DTM

  5. FDT container DTM FDT / DTM What is FDT? • FDTis a standardised software interface description • FDTdefines the co-operation between drivers (DTMs) and a FDT container PACTware is a FDTframe

  6. HART FDT / DTM What is a DTM? A DTM (Device Type Manager) is a driver for • instruments • components • communication interfaces A DTM includes all • instrument-specific data and functions • all graphic elements and dialogues for adjustment A DTMis no independently executable software

  7. Field Device Tool (FDT) Container HART FDT / DTM PACTware frame Process Automation Configuration Tool Device TypeManager (DTM)

  8. FDT / DTM PACTware frame The Device Type Manager plugs into anyFDT Compliant Frame like PACTware Manufacturer-independent: One tool for all instruments

  9. FDT / DTM System integration • One DTM for all FDT systems • Same functionality in all systems FieldCare Industrial IT or with any other FTD frame application

  10. FDT / DTM NAF-LinkIT :Overview

  11. FDT / DTM NAF-LinkIT :Parameter (Identifier)

  12. FDT / DTM NAF-LinkIT :Parameter (Parameter)

  13. FDT / DTM NAF-LinkIT :Parameter (Configuration)

  14. FDT / DTM NAF-LinkIT :Parameter (Characterization) Features • Custom defined Characteristic line with up to 22 points • Linear • Quick open • Equal percentage

  15. FDT / DTM NAF-LinkIT :Parameter (Travel) Features • Configurable travel stop • Cut-off function

  16. FDT / DTM NAF-LinkIT :Parameter (Alarms) Features • Freely defined alarm limits

  17. FDT / DTM NAF-LinkIT :Parameter (Tuning) Features • Individual setting of P and I parameters for increasing and decreasing movement

  18. FDT / DTM NAF-LinkIT :Parameter (Options) Features • Easy start up of options

  19. FDT / DTM NAF-LinkIT :Parameter (Maintenance) Features • Configuration of 4 independent Historian from 15 Minutes, hours, days up to 60 Months (5 Years) • Configuration of Service Reminder in x Hours

  20. FDT / DTM NAF-LinkIT :Parameter (Partial stroke test) Features • Intelligent valve solutions for safety systems and Emergency Shutdown (ESD) applications • On-line testing and diagnosis • Manual or Automatic activation of the test • Freely definable stroke range

  21. FDT / DTM NAF-LinkIT :Parameter (LCD) Features • Possible to turn the LCD text 180° • The LCD text is available in 3 language where the 3e language is exchangeable

  22. FDT / DTM NAF-LinkIT :Measured Values (Measurement) Features • Show measurement like Setpoint, Control deviation, valve position etc,

  23. FDT / DTM NAF-LinkIT :Measured values (Trend Viewer) Features • Trend Viewer shows SetpointStem positionValve positionControl deviationOutput 1Output 2 • The scale could easily be changed with the mouse pointer (time and value)

  24. FDT / DTM NAF-LinkIT :Diagnostics (Status Detail / Overview) Features • Easy overview show if the positioner is Ok or if there is an alarm

  25. FDT / DTM NAF-LinkIT :Diagnostics (Status Detail / Process) Features • Measured Temperature Values as Drag-Pointers for Min.- and Max. Temperatures • Temperature Alarms if the Temperature is below -40°C/°F or above 80°C/176°F • Power Supply Alarms for Low and High Power

  26. FDT / DTM NAF-LinkIT :Diagnostics (Status Detail / Hardware) Features • Information about fail in hardware like • Electronic Components • Internal Electronic Interfaces • External Electronic Interfaces • Mechanical Interfaces

  27. FDT / DTM NAF-LinkIT :Diagnostic (Status Detail / Calibration) Features • No Autostart done • Configuration

  28. FDT / DTM NAF-LinkIT :Diagnostic (Status Detail / Position Alarms) Features • Show Historical and Current alarms

  29. FDT / DTM NAF-LinkIT :Diagnostic (Status Detail / Service Management) Features • Displays the status for the operator if the valve needs to be serviced or if the valve is GOOD • Display of total non-resetable operation time in hours • Display of operation time since last service • Display of Service Reminder, when the operator shall be informed about the next service • Cycle Counter and Travel Sum

  30. FDT / DTM NAF-LinkIT :Diagnostic (Status Detail / Position History) Features • Position History to identify the valve position of valve/actuator over the time • Position History can be differentiated from 15 Minutes up to 5 Years • All data stored inside the positioner to allow later investigation in the workshop • Historian available up to 5 years

  31. FDT / DTM NAF-LinkIT :Position History - Evaluation Over specified Valve Under specified Valve

  32. FDT / DTM NAF-LinkIT :Diagnostic (Status Detail / Service Management) Features • 5 different Response Status are detected and displayed • Offline • Steady • Transient • Offset • Unstable • Response History can de differentiated from 15 Minutes up to 5 Years • All data stored inside the positioner to allow later investigation in the workshop • Historian available up to 5 years

  33. FDT / DTM NAF-LinkIT :Diagnostic (Status Detail / Service Management) Evaluation over the last 15 Minutes • 1% of its time the valve has been „Offline“ • 81% of its time the valve was in a „Steady“ state • 13 % of its time the valve was „Transient“ = moving • 4% of its time the valve was „Offset“ = remaining Control deviation • 1% of its time the valve-position was oscillating around the set point and caused the valve to be „Unstable“

  34. FDT / DTM NAF-LinkIT :Trend Viewer – Indication of Unstable control behaviour Features • Indication of leakage in piping between positioner and actuator • Leakage in actuator piston

  35. FDT / DTM NAF-LinkIT :Diagnostics (Status List) Features • “RED” Failure • “YELLOW” Maintenance required • “GREEN” Ok • “GREY” Information

  36. FDT / DTM NAF-LinkIT :Additional Functions