An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Left click (or spacebar) to advance slides and animations Presented by BWB Technologies

  2. A guide to Flame PhotometerAnalysis

  3. Introduction

  4. Introduction – Target Industries

  5. Benefits Of Flame Photometry

  6. The Principals Of Flame Photometry In other words they when we burn the sample the colour of the flame changes The basis of low temperature flame photometry is the same as that of the simple quantitative analytical flame test. This exploits the fact that compounds of the alkali and alkaline earth metals are thermally dissociated into atoms at the temperature of a Bunsen burner flame and that some of the atoms produced are further excited to a higher energy level. When these 'excited' atoms return to the ground state, they emit radiation, which for the elements of these two groups lies mainly in the visible region of the electromagnetic spectrum

  7. The Principals Of Flame Photometry

  8. The Principals Of Flame Photometry The intensity of this light is, in most cases, proportional to the absolute quantity of the species present in the flame at any moment. The number of atoms returning to the ground state is proportional to the number of atoms excited, i.e. the concentration of the sample. Note: This relationship applies only at low concentrations

  9. The Principals Of Flame Photometry

  10. The Basic Elements Of AFlame Photometer Sample

  11. The Basic Elements Of AFlame Photometer

  12. Flame Photometer Operating Data The analysis of Na, K, Li, Ba and Ca are typically determined at low temperatures, i.e., 1500-2000 C. The BWB FLAME PHOTOMETER is designed for mixtures of propane/air, butane/air and combinations of the two.

  13. Flame Photometer Operating Data Characteristic Wavelengths of the Elements It is common knowledge that when Sodium is introduced into a flame it emits a radiation in the yellow region of the visible spectrum. Table 2 gives details of the measurable atomic flame emissions of the alkali and alkaline earth metals in terms of the emission wavelength and the colours produced.

  14. What you will need The list given in this section outlines the basic equipment and reagents required to perform analysis with the BWB FLAME PHOTOMETER low temperature flame photometer. 1. BWB Flame Photometer 2. Regulated gas supply (propane, butane, or a combination of the two, LPG) 3. Power supply (90-250V ac) 4. Stock standard solutions, e.g. 10,000ppm Na, K, Li, etc. 5. Volumetric flasks for standard and sample dilution 6. Non-glass beakers or suitable sample vessels. 7. Good quality distilled or deionised water. 8. Diluent Concentrate. NOTE: For medical systems a diluter is commonly used while in many industrial applications sample preparation involves the use of common laboratory equipment, e.g. centrifuge, muffle furnace, filtration equipment, etc. Medical sample concentrations are commonly expressed in mmol/l (millimoles per litre) in contrast to ppm (parts per million), which is the typical unit used for industrial analysis. The relationship between the two is as follows. ppm = A x mmol/l mmol/l = ppm ÷A where A = atomic mass of the atom being analysed

  15. Preparing For Analysis Initial Precautions It is of the utmost importance to become familiar with the flame photometer and ancillary equipment prior to analysis. If familiarity is not achieved, inaccuracy of results or even a hazard to safety could result. Therefore, always read the instrument’s instruction manual. There are several practical points, which should be adhered to, to achieve the required accuracy in your analysis.

  16. Preparing For Analysis

  17. A Guide To Flame Photometry Thank you for watching!