Job Elders, PhD

C2V-200: a new Nessi compatible fast Micro GC IFPAC, Baltimore 2008 C2V BV, Enschede, The Netherlands. Job Elders, PhD. CEO of C2V E x GM for Alcatel Optronics NL with fiduciary responsibility Founder of TMP (Total Micro Products)

cassandraw
Download Presentation

Job Elders, PhD

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. C2V-200: a new Nessi compatible fast Micro GC IFPAC, Baltimore 2008C2V BV, Enschede, The Netherlands

  2. Job Elders, PhD • CEO of C2V • Ex GM for Alcatel Optronics NL with fiduciary responsibility • Founder of TMP (Total Micro Products) • Member of NanoNed Industrial Advisory Board & Invited referee of Dutch Nanotechnology programme (€ 245M) • Invited member of advisory board of Point One (€ 500M Philips, ASML, Economic Affairs program) • Member of program committee IOP precision technology • Advisor of Technology Accelerator of University of Twente • Co-chair of the international MANCEF MEMS Roadmap (http://www.mancef.org) • Board member of the international magazine “Micro Nano”, • Executive board member and founder of MANCEF • Member of the Management of Technology Advisory Board of the Anderson school of Management, University of New Mexico • Author of about 75 patents, technical and business papers • PhD in Physical Chemistry, University of Amsterdam • Board member of Dosimetrix LLC • Board member of foundation “Kokopelli”

  3. Key historical milestones 1991 BBV founded 2002 Management buy-out of AONL to form C2V 2007 Customer Shipments (Eng. Prototypes) 2005 C2V successfully pre-launches its Micro Gas Chromatograph 2000 BBV and TMP acquired by Kymata 2001 Kymata acquired by Alcatel. BBV and TMP integrated to form Alcatel Optronics NL 2003 C2V re-aligned to market demand 1995 TMP founded BBV Software launched 2006 Product introduction Beta site testing OEM product evaluation

  4. C2V’s fast micro GC: enables Nessi compatibility • 2000-2002: NeSSI Generation I • mechanical, passive components are on a SP76 substrate • 2002-2004: NeSSI Generation II • “electrified” passive & active components are on a SP76 substrate • integral heating and temperature control of the substrate • all electrical components are integrated with SAM • sensors and actuators communicate via sensor bus • smart (self-diagnostic) sample systems • 2005+: NeSSI Generation III • C2V-200: first high quality SP76 compatible microGC • C2V-200: micro analyzer adds value to NESSI platform • 2007: Tipping point - First large scale commercial application: • Exxon together with Siemens implements Nessi compatible sample conditioning for SPT (Singapore Parallel Train – chemical plant in Singapore)

  5. Conventional GC (Macro drawbacks) Life-time Reliability Reproducibility Calibration (s) Quantitation (ppm) Consumables Fast micro GC Cartridge (Micro advantages) System loading x10< IC derived manufacturing IC-based tolerances, QA/QC Highly controlled operating parameters (temperature, flow, etc.) Highly stable system performance Longer life-time, lower flow rates, Fast micro GC vs. conventional GCTechnical Features / Benefits Limited life-time (6 months) Extended life-time (2-5 years) smaller • faster • better • for less costs

  6. Conventional GC (Macro drawbacks) Requires skilled engineers Requires trained service-men Requires significant CapEx investment Fast micro GC Cartridge (Micro advantages) System pre-programmed Exchange of cartridge by laymen Does not require significant CapEx Enables innovative revenue model, from CapEx to OpEx budgets Fast micro GC versus conventional GCTechnical Features / Benefits Requires expert know how Complicates sales process Simplifies usage Simplifies sales process smaller • faster • better • for less costs

  7. C2V-200 micro GC C2V’s unique MEMS micro fluidics integration platform enables a world-class handheld chip-based GC instrument. → Fast analysis: 10-30 seconds → Handheld sized → Easy exchangeable GC channel cartridges → Low power system (< 15 W typical) → Low costs (decrease per increasing volume) → Excellent separation: N=10’000-25’000 → Operating up to 180 oC → Fast T ramping: 100 oC / minute → ppm sensitivity with TCD → Less carrier/reference gas (operational 1 ml/min.) → Diagnostics on chip: flow/pressure smaller • faster • better • for less costs

  8. C2V’s micro GC technology platform Chip technology Using micro technology to create low cost GC components (valves, injector, detector, column, flow system, heating, flow diagnostics) with low internal volume and low thermal mass Integration of chips Using a fluidic multi chip module for integration of these chip components in a fluidic system with low dead volume connections Cartridge The fluidic system module is assembled on an exchangeable cartridge that contains the core GC functionality smaller • faster • better • for less costs

  9. GC Components: chips technology Micro Injector: • Channel array chip • Membrane valves • Pneumatic actuation Micro TCD Detector: • ppm sensitivity • ms response Silicon columns: • Fast heating • Integration on-chip Capillary columns: • Commercial available • Opt. geometry smaller • faster • better • for less costs

  10. Fast GC Cartridge C2V fast GC easy exchangeable cartridge (2” x 3.5” x 0.6”) contains: • Injector and sample loop • TCD detector • Column • Heating (2 zones) C2V-200 micro GC module (3” x 4.5” x 1.2”) contains: • Easy exchangeable cartridge • Gas tight cartridge package • Read-out & control electronics • Pneumatics hardware • Connectors (gas & data & power) smaller • faster • better • for less costs

  11. Fast GC Cartridges smaller • faster • better • for less costs

  12. Fast GC Cartridges GCC1000 separation is almost entirely based on boiling points making this cartridge suitable for a wide range of applications. Typical components: alcohols, esters, flavors and aromas, free fatty acids, glycols, hydrocarbons, ketones, organic acids, oxygenates, PAHs, pesticides, polymers, steroids, solvents, sulfur compounds. GCC1010 elutes polar compounds as perfectly symmetrical peaks, allowing them to be analyzed together with light hydrocarbons or permanent gases. Typical components: halogenated compounds, hydrocarbons C1-C6, H2S, ketones, oxygenated hydrocarbons, permanent gases/solvents. GCC1020 provides optimal selectivity for many aqueous soluble compounds. Typical components: BTEX, methanol, alcohols, aromatic hydrocarbons, esters, FAME, flavors and aromas, free fatty acids, glycols, halogenated compounds, ketones, organic acids and solvents. GCC1030 (molecular-sieve coated capillary column) is especially valuable when separating permanent gases. Typical gases separated with the GCC1030 include: He, H2, O2, CO, Ne, HD, N2, NO, Ar, D2, CH4, KrHT, X3, DT, CD4, Rn, T2. GCC1040 separates N2, O2, CO, CO2 and C1-C2 hydrocarbons. Typical gases separated by the GCC1040 include: He, Xe, CO, Ne, CH4, CO2, O2/Ar, C2H6, N2, C2H4, Kr and C2H2 smaller • faster • better • for less costs

  13. C2V’s fast micro GC: data management • C2V platform accommodates: • Fieldbus • Profibus • Modbus • Wireless • And interfaces with: • RS 232 • USB smaller • faster • better • for less costs

  14. Natural gas analysis (up to C5) VB1 column: → 12 seconds @ 50 C → High separation quality → C2-C5, neo-pentane visible Poraplot column: → 18 sec @ 80 C → High separation quality → N2, CH4, CO2, C2H6, C3H8 • Injection time 10 msec • Column 50oC, chip 100oC • Pactuation = 3 bar • PHE=PNG = 1.5 bar • column: VB1 • column: 5m/0.18mm/1mm smaller • faster • better • for less costs

  15. Natural gas analysis: C3-C6 smaller • faster • better • for less costs

  16. Natural gas: Temperature Program Run smaller • faster • better • for less costs

  17. BTEX headspace measurement → Very fast separation < 20 seconds (60oC) → Excellent separation quality → Zero peak tailing → Headspace injection 5m CP-Sil-8, 60oC, 2 bar, 200 ms injection time smaller • faster • better • for less costs

  18. Reproducibility Reproducibility test: > 100,000 runs to date Showing results of 5,000 consecutive runs Demonstrates: stability and reliability: • Flow control • Temperature control • Injection repeatability smaller • faster • better • for less costs

  19. Reproducibility Retention time results: 5,000 consecutive runs smaller • faster • better • for less costs

  20. Reproducibility Peak height results: 5,000 consecutive runs smaller • faster • better • for less costs