Resp/Vent Nomenclature – Modeling dynamic variables

Resp/Vent Nomenclature – Modeling dynamic variables. IEEE 11073-ISO SC4 19223-IHE PCD RTM JWG D3G_9Sep14. Overview. Scope is limited to defining dynamic variables, i.e. breath types, rates, and volumes Purpose

Download Presentation

Resp/Vent Nomenclature – Modeling dynamic variables

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Resp/Vent Nomenclature – Modeling dynamic variables IEEE 11073-ISO SC4 19223-IHE PCD RTM JWG D3G_9Sep14

  2. Overview • Scope is limited to defining dynamic variables, i.e. breath types, rates, and volumes • Purpose • Primary purpose is to define a fundamental set based on ISO SC4 methodology that can be used as a basis for data logging of ‘dynamic’ variables, i.e. breath types, rates, and volumes, such as tidal and minute volume. • Secondary purpose is to show how fundamental breath type variables can be used to explain ‘traditional’ connotations such as ‘spont[aneous]’ and ‘mand[atory]’. • Approach • Harmonization is based on alternative modeling perspectives • Synergy: breaths are viewed as holistic, or system-level co-actions of patient and ventilator. • Phasing: features are viewed as phased element-level actions of patient and ventilator Compositional correspondence: several Rate variables are related to [four] fundamental breath types. • Several application examples are described: • Rate: variables are summated w.r.t. a typical modal pattern (e.g. SIMV) • Nomenclature: RefID formulation is shown for common RESP_RATE variations. • Volume: several variables related to “Exhaled Minute Volume” are derived Modal correspondence: several key variables are related to common Ventilator Modes. IEEE 11073-ISO SC4 19223-IHE PCD RTM JWG d3f

  3. Synergy perspective • Breath types represent fundamental co-action patterns w.r.t. patient and ventilator. • Refer to following diagram for derivation of breath types and table for identification of key rate relationships • Breath types are composites of co-active relationships and named according to common usage. • Rates may be ascribed to various elements or subsets of graph in the diagram. IEEE 11073-ISO SC4 19223-IHE PCD RTM JWG d3f

  4. Phasing perspective • Breath types represent fundamental phasing relationships, primarily w.r.t. initiation. “SD” refers to “Start” and “Delivery” phasing elements. • Refer to following table for derivation of breath types • Breath types are n-tuple composites of phasing sequences, e.g. n=2 (for S & D) in the following table; precision may be increased by extension, for example, by adding an “E” (End) phase • SD Type correspondence as shown in previous diagram, e.g. Unassisted (P), Supported (S), Assisted (A), Controlled (C). • Rates may be ascribed to time-ordered occurrences as shown in the annotated diagram beneath the table. IEEE 11073-ISO SC4 19223-IHE PCD RTM JWG d3f

  5. Relational correspondence The following table shows a relation mapping terms based on the alternative perspectives. IEEE 11073-ISO SC4 19223-IHE PCD RTM JWG d3f

  6. Example applications – Rate Note: See below for annotation key for this particular (preliminary) diagram. IEEE 11073-ISO SC4 19223-IHE PCD RTM JWG d3f

  7. Example applications: Nomenclature RefID Application for defining Nomenclature “Reference IDs” is characterized in the following example, for key “Resp Rate” variations. Discriminator tags (“P”, “S”, “A”, “C”} shown in the “Phasing perspective” table are formed into a char string denoting summary formulation, in order to facilitate systematic computation. Base term: MDC_VENT_RESP_RATE [existing term code 2::20514] REFID (as observations, not settings)Equivalent to MDC_VENT_RESP_RATE_BTSD_PS BTSD = patient | supported (aka ‘traditional spontaneous’) MDC_VENT_RESP_RATE_BTSD_AC BTSD = assisted | controlled (aka ‘traditional mandatory’) MDC_VENT_RESP_RATE_BTSD_PSA BTSD = patient | supported | assisted MDC_VENT_RESP_RATE_BTSD_C BTSD = controlled IEEE 11073-ISO SC4 19223-IHE PCD RTM JWG d3f

  8. Example applications – Volume Several volume-related term derivations and relationships to rate terms are listed in the following table. IEEE 11073-ISO SC4 19223-IHE PCD RTM JWG d3f

  9. Modal context correspondence Context-sensitive, modal relationships are shown in the following table. [Note: ID tags are used only for concise reference in the table.] IEEE 11073-ISO SC4 19223-IHE PCD RTM JWG d3f

More Related