Steam Condensation Effect in Hydrogen Venting from a BWR reactor building

Steam Condensation Effect in Hydrogen Venting from a BWR reactor building. University of Tokyo Masahiro Kondo, Nejdet Erkan , Koji Okamoto. Background. In Fukushima- daiichi NPP accident, hydrogen explosion effected the following mitigation measures.

Download Presentation

Steam Condensation Effect in Hydrogen Venting from a BWR reactor building

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Steam Condensation Effect in Hydrogen Venting from a BWR reactor building University of Tokyo Masahiro Kondo, NejdetErkan, Koji Okamoto ICHS 2015 Oct. 19-21

  2. Background • In Fukushima-daiichi NPP accident, hydrogen explosion effected the following mitigation measures. • Hydrogen ventingwas considered in Japan. • CRIEPI evaluated its efficiency using a CFD (computational fluid dynamics) and a LP (lumped parameter) model [1-4] • No steam condensation model was included, although it might effect the building atmosphere [1-4] Kondo M. Yoneda K. Nishi Y. and Inada F. “Reasearch on the hydrogen venting from the BWR reactor building at severe accident”, Proceedings of JSME annual meeting 2012, S083012-S083015 ICHS 2015 Oct. 19-21

  3. Steam Condensation Effect • Concentration effect • Vent-enhancing effect Steam Air Steam Hydrogen Air Hydrogen condensation Hydrogen might be concentrated due to condensation. Condensation heat might enhance the venting. heat-up Q. There exist both negative and positive effect. Which is dominant? ICHS 2015 Oct. 19-21

  4. Objective • To study steam condensation effect in hydrogen venting • CFD calculation • The case where hydrogen-steam mixture flows into the building (hydrogen-steam case) • The case where hydrogen nitrogen mixtureflows into the building (hydrogen-nitrogen case) • LP evaluation • Evaluation results and evaluation time are compared to the CFD calculation. • A Parameter study is conducted with the LP model. comparison ICHS 2015 Oct. 19-21

  5. Calculation Geometry water film on inner wall surface evaporation/condensation model adopted concrete wall 2240kg/m3, 750 J/kgK, 0.53 W/mK 40 m 50 m reference section 18 m wall width : 0.3m window(2m x 2m) outer space gas mixture inlet pressure boundary 303K, O2:N2=0.21:0.79,101325 Pa velocity inlet boundary 473K (please correct proceeding page 4 line 3) H2:H2O=0.5:0.5 (hydrogen-steam case) or H2:N2=0.5:0.5 (hydrogen-nitrogen case) 0.72 m3/s (equivalent to 1600kg hydrogen / 24 hours) ICHS 2015 Oct. 19-21

  6. Calculation Model and Parameters • Transient calclulationusing STAR-CCM+ • Δt = 1.0 sec • gravity = 9.81 m/s2 • gas mixture • multi-component gas • H2,O2,H2O,N2 • k-e turbulent model • water film • density: 997.6 kg/m3 • specific heat: 4181 J/kgK • thermal conductivity: 0.62 w/mK • latent heat: 2500 kJ/kg • concrete wall • density: 2240kg/m3 • specific heat: 750 J/kgK • thermal conductivity: 0.53 W/mK • external heat transfer coefficient: 4.0 W/mK ICHS 2015 Oct. 19-21

  7. Mesh Configuration 2 layer meshes + 6 wall meshes window mesh size: 1 m outer space meshes on the reference section meshes around the window ICHS 2015 Oct. 19-21

  8. Hydrogen Distribution Small difference in hydrogen concentration t = 2.0 hour t = 2.0 hour 0.00 0.04 0.08 0.12 t = 4.0 hour t = 4.0 hour t = 6.0 hour t = 6.0 hour t = 8.0 hour t = 8.0 hour Hydrogen Concentration (mol/mol) t = 10.0 hour t = 10.0 hour (b) hydrogen-nitrogen case (a) hydrogen-steam case ICHS 2015 Oct. 19-21

  9. Temperature Distribution t = 2.0 hour Large differencedue to condensation heat t = 2.0 hour t = 4.0 hour Temperature (C) t = 4.0 hour t = 6.0 hour t = 6.0 hour t = 8.0 hour t = 8.0 hour 30.0 40.0 50.0 t = 10.0 hour t = 10.0 hour (b) hydrogen-nitrogen case (a) hydrogen-steam case ICHS 2015 Oct. 19-21

  10. History of Hydrogen Concentration and Temperature Temperature rise in hydrogen-steam case was larger after condensation started, because of condensation heat. Hydrogen concentration was slightly lower in the hydrogen-steam case,because condensation heat enhanced venting. In this calculations, main difference was due to condensation heat ICHS 2015 Oct. 19-21

  11. LP (Lumped Parameter)model • condensation model[5] • Stefan’s law • model for vertical opening [6] • Counter-current flow z w zout_h outflow uout(z) zout_l zin_h inflow uin(z) zin_l The history of hydrogen concentration and temperature are predicted using these models and compared with the CFD results. [5] Kondo M., Yoneda K., Furuya M., Nishi Y., JNST (2015) doi:10.1080/00223131.2014.1000993. [6] Proceedings of 2015 annual meeting of AESJ (2015) I12. ICHS 2015 Oct. 19-21

  12. CFD vs LP With LP model, the results equivalent to the CFD’s were obtained much faster. ICHS 2015 Oct. 19-21

  13. Parameter Study using LP model Impact on area of the window Hydrogen concentration in hydrogen-steam case is higher. ”concentration effect” is dominant Hydrogen concentration in hydrogen-steam case is lower. ”vent enhancing effect” is dominant Both “concentration effect” and “vent-enhancing effect” are observed, but dominant effect changes depending on the opening conditions. ICHS 2015 Oct. 19-21

  14. Conclusion • To study steam condensation effect in hydrogen venting • CFD calculation • hydrogen-steam case and hydrogen-nitrogen are compared • In the calculated case, difference in hydrogen concentration was small, but the large temperature difference was observed. • comparison between LP and CFD • LP could obtain equivalent results to CFD in much smaller prediction time. • parameter study using LP • Both “concentration effect” and “vent-enhancing effect” is observed, depending on the opening conditions. ICHS 2015 Oct. 19-21