PET/CT 常见的伪影分析

PET/CT 常见的伪影分析. 刘家 金 解放军总医院. 伪影:指在扫描或信息处理过程中产生的某些异常影像 , 与病变本身无关 , 但降低图像质量 , 妨碍病变的分析。. PET/CT 伪影. 伪影类型. 一、 CT 衰减校正所致伪影. 二、运动所致伪影. 三、技术操作所致伪影. 四、设备故障所致伪影. 一、 CT 衰减校正所致伪影.

Download Presentation

PET/CT 常见的伪影分析

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. PET/CT常见的伪影分析 刘家金 解放军总医院

  2. 伪影:指在扫描或信息处理过程中产生的某些异常影像, 与病变本身无关, 但降低图像质量, 妨碍病变的分析。 PET/CT伪影

  3. 伪影类型 一、CT衰减校正所致伪影 二、运动所致伪影 三、技术操作所致伪影 四、设备故障所致伪影

  4. 一、CT衰减校正所致伪影 • 1、CT衰减校正方法学:PET/CT的校正用CT进行透射扫描计算X线衰减系数,然后转化为511KeV射线衰减系数,再对PET发射扫描进行补偿校正。由于X 射线与γ光子射线能量间存在差异, 两者有不同的组织衰减分布, X 射线不能直接用于衰减校正, 必须把低能级光子的衰减系数转换为高能级光子的衰减系数, 转化过程中就会产生误差。

  5. 一、CT衰减校正所致伪影 • 2、体内金属植入物:部分患者体内或体表携带的金属植入物,经CT 衰减校正后在PET 图像上表现为一个高放射性浓聚灶,参考相应非衰减校正图像或68Ge 衰减校正图像可见相应位置无异常放射性浓聚, 提示该处为CT 校正导致的伪影。这种伪影需要与肿瘤病灶鉴别,需重建非衰减校正图像。产生这种伪影的主要原因是由于目前使用的CT 衰减校正方法对高原子序数材料的衰减值计算存在不足。

  6. 一、CT衰减校正所致伪影 1、CT衰减校正方法学 2、体内金属植入物 3、对比剂

  7. 四、设备故障所致伪影

  8. 二、运动所致伪影 1、运动后显像 2、受检者体位移动 3、呼吸运动 4、胃肠道蠕动

  9. 三、技术操作所致伪影 1、示踪剂质量 2、注射点外漏 3、污染 4、机器操作

  10. 四、设备故障所致伪影