1 / 23

Motor Protection Circuit Breaker Catalog - c3controls

The c3controls Series 330 Motor Protection Circuit Breakers catalog highlights a range of compact, reliable devices designed to protect motors from overloads and short circuits. These breakers are easy to install on a 35mm DIN rail, work with various accessories for simplified wiring, and are ideal for multi-motor setups, saving space, time, and costs. They meet global standards (UL Listed and CE marked), offer features like thermal and magnetic trip elements, and come with a limited lifetime warranty and same-day shipping.

c3controls
Download Presentation

Motor Protection Circuit Breaker Catalog - c3controls

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. POWER & ACTUATION s e r i e s MOTOR PROTECTION s e r i e s s e r i e s s e r i e s s e r i e s 30 industrial 22 i e c TB i e c 300 CIRCUIT BREAKERS 310 reversing s e r i e s s e r i e s s e r i e s s e r i e s 330 CS 620 630 non-reversing c3controls’ Series 330 Motor Protection Circuit Breakers provide reliable overload and short circuit protection for all your motor control applications. Our motor protection circuit breakers are ideal for use in multi-motor applications – providing space savings, labor savings, and cost savings. They install on a standard 35mm DIN rail, and they work with a variety of accessories to make wiring as easy as possible. s e r i e s s e r i e s s e r i e s s e r i e s s e r i e s 30 hazardous 22 n e m a TB n e m a 300 miniature 310 miniature Section 9 Motor Protection Circuit Breakers with Thermal and Magnetic Trip Elements Motor Protection Circuit Breakers with Magnetic Trip Elements External Operating Handle Accessories Specifications Circuit Diagrams Trip Characteristics Dimensions s e r i e s 6 TB 7 10 11 14 19 20 21 PROVEN Conformity to Standards: UL 508, 60947-4-1 CSA C22.2 No. 14 IEC 60947-1, 60947-4-1 Certifications: UL File #: E187641 (Guide NLRV, NLRV7), E312106 (Guide NKJH, NKJH7) CE Marked (per EU Low Voltage Directive 2006/95/EC and RoHS Directive 2011/65/EU) Visit www.c3controls.com to download product certifications. NOTE: The scope (range, description, price, specifications, dimensions, etc.) of the product featured in this section is subject to change without notice. Refer to www.c3controls.com for product updates. REVISION 06.2022

  2. s e r i e s s e r i e s s e r i e s s e r i e s s e r i e s 30 industrial 22 i e c TB i e c 300 310 reversing s e r i e s s e r i e s s e r i e s s e r i e s 330 MOTOR PROTECTION CIRCUIT BREAKERS / CS MOTOR PROTECTION CIRCUIT BREAKERS c3controls offers a comprehensive line of Motor Control products designed and manufactured to meet the needs of the machine builder. We promise durable products at a price that gives you an edge, and we guarantee same-day shipping. Check out all the features of our Series 330 Motor Protection Circuit Breakers below! 620 630 non-reversing s e r i e s s e r i e s s e r i e s s e r i e s s e r i e s 30 hazardous 22 n e m a TB n e m a 300 miniature 310 miniature s e r i e s TB DELIVERING SUPERIOR PRODUCT QUALITY AND MANUFACTURING EXCELLENCE Our Series 330 Motor Protection Circuit Breakers are UL Listed and CE marked meeting global standards requirements. Proven Our self-protected devices eliminate the need for upstream fuses and circuit breakers, and they provide reliable motor protection. Self-Protected Only 45mm (1-49/64”) wide up to 20HP @ 460V (15kW @ 400V) in both thermal and magnetic and magnetic only versions. Compact Including standard auxiliary contacts, trip indicating auxiliary contacts, shunt and undervoltage release modules, and many wiring accessories such as commoning links and feeder terminals for easy distribution of power to multiple motor protection circuit breakers. Wide Variety of Accessories Modular design allows Series 330 Motor Protection Circuit Breakers to be easily used with the complete range of Series 300 Contactors and accessories. Modular Design 35mm DIN rail mounting for fast and easy installation and removal, or panel mounting with mounting feet for more secure installation in high shock and vibration applications. Easy to Install High visibility labels and markings; dual IEC and NEMA terminal markings for ease of wiring anywhere in the world. Visible Markings Control panel sizes can be reduced because the short circuit protection provided by the Series 330 enables individual motor branch circuit fuses or circuit breakers and overload relays to be eliminated. Space Savings IP20 guarded terminals with dual terminal markings prevent accidental contact with live parts. Added Safety Every product is backed by our limited lifetime warranty—unmatched in the industry— bringing you quality components that perform in the most demanding applications. Limited Lifetime Warranty* Guaranteed Same-Day Shipping* Product availability reduces inventory, and improves cash-flow—saving you money. With c3controls any order for standard catalog items received by 6:00pm ET is guaranteed to ship same-day. Our approach to product development, manufacturing, and focus on servicing the OEM and Electrical Equipment Builder reduces cost. The result—the best value in the industry. Advantage Pricing “ *See c3controls Terms & Conditions ” We began to think we weren’t going to find a vendor who could provide us with Motor Protection Circuit Breakers at a price that made replacing fuses affordable. And then we found c3controls. Joe O’Leary, Chief Engineer ·Aztec Machinery Company Section 9 | 2724.775.7926 :: www.c3controls.com

  3. s e r i e s s e r i e s s e r i e s s e r i e s s e r i e s 30 industrial 22 i e c TB i e c / MOTOR PROTECTION CIRCUIT BREAKERS 300 310 reversing s e r i e s s e r i e s s e r i e s s e r i e s 330 CS 620 630 non-reversing Motor Protection circuit Breakers s e r i e s s e r i e s s e r i e s s e r i e s s e r i e s 30 hazardous 22 n e m a TB n e m a 300 miniature 310 miniature MPCB w/Thermal & Magnetic Trip Elements MPCB w/Magnetic Trip Elements Type E MPCB s e r i e s TB UNIQUE PRODUCT LINE FEATURES MULTI-FUNCTION DEVICE SELF-PROTECTED HIGH FAULT SCCR ARTICLE 430 PART VII - NFPA 70 To Supply NEC Part Motor disconnecting means Motor branch-circuit, short circuit, and ground-fault protection Motor circuit conductor Motor controller Motor control circuits Motor overload protection Part IX Part IV Part II Part VII Part VI Part III Motor Part I Our Series 330 MPCBs are certified as Manual Motor Controllers Suitable as Motor Disconnects, can be used in Group Motor Installations, and can be used to manually control individual motors and protect them against overload and short circuit currents. Listed as a UL 60947-4-1 Type E self-protected combination Manual Motor Controller for circuits capable of delivering up to 50kA @ 460V. High fault short circuit current rating of 50kA @ 480V provides safety and reliability in high fault applications. SEAMLESS COMPATIBILITY ADJUSTABLE CURRENT SETTING SNAP-ON ACCESSORIES The modular design of our Series 330 MPCB allows for direct mounting onto Series 310 (9A to 40A) AC/DC Contactors and Series 300 and 310 AC/DC Miniature Contactors. Full load current adjustment ratio enables overload relay to be set to exact FLA of motor. Provides phase protection for the motor against overload currents. Snap-on accessories are easily installed without the use of tools, lowering assembly and installation costs. FIND IT Motor Protection Circuit Breakers • Certifications • Specifications • Dimension Drawings • Installation Instructions • Easy to Buy FAST www.c3controls.com Everything under control :: c3controlsSection 9 | 3

  4. s e r i e s s e r i e s s e r i e s s e r i e s s e r i e s 30 industrial 22 i e c TB i e c 300 310 reversing s e r i e s s e r i e s s e r i e s s e r i e s 330 MOTOR PROTECTION CIRCUIT BREAKERS / CS 620 630 non-reversing Motor Control Device Solutions s e r i e s s e r i e s s e r i e s s e r i e s s e r i e s 30 hazardous 22 n e m a TB n e m a 300 miniature 310 miniature c3controls motor control devices are the perfect solution for manufacturers who want proper motor control and superior motor protection without having to overpay or compromise on quality. In fact, we engineer so much performance and flexibility into our products, we can deliver a remarkably better value than our competitors. s e r i e s TB c3controls products deliver like no other. Seamless Compatibility Contactors, overload relays and motor protection circuit breakers are designed by c3controls to work together, with common connections and accessories, resulting in a high functioning compact starter. LEADING THE INDUSTRY with our compact miniature 10HP contactors and control relays. One frame size (AC or DC)—28% reduction in panel area. Compact The small size of c3controls motor control devices, plus features like common accessories, enable assembly into smaller control panels for lower installed costs. Reliable Protection Contactors provide the repeated on/off switching for the motor and are designed for motor, actuator, solenoid, and other power switching applications. Overload relays provide Trip Class 10 protection against overload and phase-loss conditions, and have ambient temperature compensation for motor protection in high temperature environments. Motor protection circuit breakers provide overload, phase-loss and short circuit protection, can be used by themselves as manual motor controllers or with contactors in group motor installations, and can achieve Type 2 coordination for optimum performance. Ensures the protection of equipment and user. Type E self-protected combination manual motor controllers provide disconnecting means, branch circuit protection, motor control and motor overload protection all in a single device. Proven Our motor control devices are UL Listed and CE marked, meeting global standards requirements for use anywhere in the world. Section 9 | 4724.775.7926 :: www.c3controls.com

  5. s e r i e s s e r i e s s e r i e s s e r i e s s e r i e s 30 industrial 22 i e c TB i e c / MOTOR PROTECTION CIRCUIT BREAKERS 300 310 reversing s e r i e s s e r i e s s e r i e s s e r i e s 330 CS 620 630 non-reversing NFPA 70 - National Electrical Code (NEC) TB n e m a Motor Protection circuit Breakers s e r i e s s e r i e s s e r i e s s e r i e s s e r i e s 30 hazardous 22 n e m a 300 miniature 310 miniature Understanding what functions are needed in your motor control circuit is critical when selecting motor control devices. Engineers benefit from the standards and codes established to ensure safety and protection to personnel and equipment. s e r i e s TB More than just knowing the standards, c3controls, as a manufacturer of motor control products, has the application expertise you need to select the right products. Our motor control products align with Article 430 Part VII, Motor Controller, of the NFPA 70, the National Electrical Code. c3controls & Article 430 - Motors, Motor Circuits and Controllers To Supply NEC Part c3controls Product Series Motor disconnecting means Part IX 330 630 Type E: 330 630 Motor branch- circuit, short circuit, and ground-fault protection Part IV Type E: 330 630 Motor circuit conductor Part II Motor controller Part VII Type E: 330 630 300/310 330 620 630 Motor control circuits Part VI Motor overload protection Part III Type E: 330 630 320 330 620 630 Motor Part I Everything under control :: c3controlsSection 9 | 5

  6. s e r i e s s e r i e s s e r i e s s e r i e s s e r i e s 30 industrial 22 i e c TB i e c 300 310 reversing s e r i e s s e r i e s s e r i e s s e r i e s 330 W/THERMAL & MAGNETIC TRIP ELEMENT / CS 620 630 non-reversing I T ’ S E A S Y T O B U I L D Y O U R O W N C I R C U I T B R E A K E R s e r i e s s e r i e s s e r i e s s e r i e s s e r i e s 30 hazardous 22 n e m a TB n e m a 300 miniature 310 miniature Simply pick the code number from each of the sections below and combine them to build your part number. Motor Protection Circuit Breakers with Thermal and Magnetic Trip Elements 330-T25S I II Example: To build one of our most popular Circuit Breakers, the part number would be 330-T25S + II or 330-T25S2U32 s e r i e s TB I. MOTOR PROTECTION CIRCUIT BREAKER TYPE CODE DESCRIPTION 330-T25S 32A Motor Protection Circuit Breaker with Thermal and Magnetic Trip Elements Provides overload and short circuit protection. SCHEDULEF DISCOUNT II. CURRENT AND POWER RATINGS ULTIMATE INTERRUPTING CURRENT (Icu) (kA) 400V 100 100 100 100 100 100 100 100 100 100 50 50 50 50 RATED OPER. CURRENT (A) 0.16 0.25 0.40 0.63 1.0 1.6 2.5 4.0 6.3 10 16 20 25 32 MAGNETIC TRIP CURRENT (A) 2.1 3.3 5.2 8.2 13 21 33 52 82 130 208 260 325 416 CODE 2C16 2C25 2C40 2C63 2D10 2D16 2D25 2D40 2D63 2U10 2U16 2U20 2U25 2U32 RATINGS FOR SWITCHING AC MOTORS* 3 PHASE kW (50Hz) 400/415V 500V 690V — — 0.06 0.06 0.06 0.12 0.09 0.12 0.18 0.12 0.25 0.25 0.25 0.37 0.55 0.55 0.75 1.1 0.75 1.1 1.5 1.5 2.2 2.2 3 4 4 7.5 7.5 9 12.5 9 12.5 12.5 15 15 18.5 ADJUSTMENT RANGE (A) 0.10 ~ 0.16 0.16 ~ 0.25 0.25 ~ 0.40 0.40 ~ 0.63 0.63 ~ 1.0 1.0 ~ 1.6 1.6 ~ 2.5 2.5 ~ 4.0 4.0 ~ 6.3 6.3 ~ 10 10 ~ 16 16 ~ 20 20 ~ 25 25 ~ 32 3 PHASE HP (60Hz) 230V — — — — — 1/3 1/2 1 1-1/2 3 5 7-1/2 7-1/2 10 480V 100 100 100 100 100 100 100 100 100 42 10 10 10 10 230V — — — 0.06 0.12 0.18 0.37 0.75 1.1 2.2 3.7 3.7 5.5 7.5 200V — — — — — 1/4 1/2 3/4 1-1/2 3 5 5 7-1/2 10 460V — — — — 1/2 3/4 1-1/2 2 3 7-1/2 10 15 15 20 575V — — — 1/4 1/2 1 1-1/2 3 5 10 15 20 20 25 LIST $122.00 $122.00 $132.00 $136.00 $139.00 $139.00 $139.00 $139.00 $148.00 $154.00 $170.00 $185.00 $218.00 $218.00 3 4 15 22 30 *NOTE: HP and kW ratings shown in the table above are for reference. The final selection of the motor protection circuit breaker must be based on the actual motor full load current. Someof our PoPular ConfigurationS: MOTOR PROTECTION CIRCUIT BREAKERS WITH THERMAL AND MAGNETIC TRIP ELEMENTS CATALOG NUMBER 330-T25S2D63 330-T25S2U10 330-T25S2U16 330-T25S2U20 DESCRIPTION 6.3A Motor Protection Circuit Breaker with Thermal and Magnetic Trip Elements 10A Motor Protection Circuit Breaker with Thermal and Magnetic Trip Elements 16A Motor Protection Circuit Breaker with Thermal and Magnetic Trip Elements 20A Motor Protection Circuit Breaker with Thermal and Magnetic Trip Elements LIST $148.00 $154.00 $170.00 $185.00 Section 9 | 6724.775.7926 :: www.c3controls.com

  7. s e r i e s s e r i e s s e r i e s s e r i e s s e r i e s 30 industrial 22 i e c TB i e c / W/MAGNETIC TRIP ELEMENT 300 reversing 310 s e r i e s s e r i e s s e r i e s s e r i e s 330 CS 620 630 non-reversing Motor Protection circuit Breakers I T ’ S E A S Y T O B U I L D Y O U R O W N C I R C U I T B R E A K E R TB n e m a s e r i e s s e r i e s s e r i e s s e r i e s s e r i e s 30 hazardous 22 n e m a 300 miniature 310 miniature Simply pick the code number from each of the sections below and combine them to build your part number. Motor Protection Circuit Breakers with Magnetic Trip Element 330-M25S I II Example: To build one of our most popular Circuit Breakers, the part number would be 330-M25S + II or 330-M25S2D16 s e r i e s TB I. MOTOR PROTECTION CIRCUIT BREAKER TYPE CODE DESCRIPTION 330-M25S 32A Motor Protection Circuit Breaker with Magnetic Trip Element Provides short circuit protection. SCHEDULEF DISCOUNT II. CURRENT AND POWER RATINGS ULTIMATE INTERRUPTING CURRENT (Icu) (kA) 400V 100 100 100 100 100 100 100 100 100 100 50 50 50 50 MAGNETIC TRIP CURRENT (A) RATED OPERATING CURRENT (A) CODE 2C16 0.16 2.1 2C25 0.25 3.3 2C40 0.40 5.2 2C63 0.63 8.2 2D10 1.0 13 2D16 1.6 21 2D25 2.5 33 2D40 4.0 52 2D63 6.3 82 2U10 10 130 2U16 16 208 2U20 20 260 2U25 25 325 2U32 32 416 RATINGS FOR SWITCHING AC MOTORS* 3 PHASE kW (50Hz) 400/415V 500V 690V — — 0.06 0.06 0.06 0.12 0.09 0.12 0.18 0.12 0.25 0.25 0.25 0.37 0.55 0.55 0.75 0.75 1.1 1.5 2.2 2.2 3 4 4 7.5 9 12.5 9 12.5 12.5 15 15 18.5 3 PHASE HP (60Hz) 230V — — — — — 1/3 1/2 1 1-1/2 3 5 7-1/2 7-1/2 10 480V 100 100 100 100 100 100 100 100 100 42 10 10 10 10 230V — — — 0.06 0.12 0.18 0.37 0.75 1.1 2.2 3.7 3.7 5.5 7.5 200V — — — — — 1/4 1/2 3/4 1-1/2 3 5 5 7-1/2 10 460V — — — — 1/2 3/4 1-1/2 2 3 7-1/2 10 15 15 20 575V — — — 1/4 1/2 1 1-1/2 3 5 10 15 20 20 25 LIST $122.00 $122.00 $132.00 $136.00 $139.00 $139.00 $139.00 $139.00 $148.00 $154.00 $170.00 $185.00 $218.00 $218.00 1.1 1.5 3 4 7.5 15 22 30 *NOTE: HP and kW ratings shown in the table above are for reference. The final selection of the motor protection circuit breaker must be based on the actual motor full load current. Someof our PoPular ConfigurationS: MOTOR PROTECTION CIRCUIT BREAKERS WITH MAGNETIC TRIP ELEMENT CATALOG NUMBER 330-M25S2D63 330-M25S2U10 330-M25S2U16 330-M25S2U20 DESCRIPTION 6.3A Motor Protection Circuit Breaker with Magnetic Trip Element 10A Motor Protection Circuit Breaker with Magnetic Trip Element 16A Motor Protection Circuit Breaker with Magnetic Trip Element 20A Motor Protection Circuit Breaker with Magnetic Trip Element LIST $148.00 $154.00 $170.00 $185.00 Everything under control :: c3controlsSection 9 | 7

  8. s e r i e s s e r i e s s e r i e s s e r i e s s e r i e s 30 industrial 22 i e c TB i e c 300 310 reversing s e r i e s s e r i e s s e r i e s s e r i e s 330 MOTOR PROTECTION CIRCUIT BREAKERS / CS 620 630 non-reversing motor ProteCtion CirCuit BreakerS c3controls Series 330-T25S Motor Protection Circuit Breakers include both thermal and magnetic trip elements for overload and short circuit protection. They are ideal for use with Series 300 Contactors in group motor installations where panel space is at a premium and device modularity is required to satisfy virtually any application requirement. For the simplest applications, they can also be used by themselves as manual motor controllers. cULus and CE Markings make them suitable for use anywhere in the world. Small size, IP20 guarded terminals with dual terminal markings, and shared accessories will help reduce your total installed costs and enhance the features and performance of your equipment. Just look and see what the Series 330-T25S and 330-M25S have to offer. Product features include: • Series 330 Motor Protection Circuit Breakers direct mount onto: – Series 300 Non-Reversing and Series 310 Reversing, 9A to 40A AC and DC, Contactors – Series 300-M Miniature Non-Reversing and Series 310-M Miniature Reversing AC and DC Contactors s e r i e s s e r i e s s e r i e s s e r i e s s e r i e s 30 hazardous 22 n e m a TB n e m a 300 miniature 310 miniature s e r i e s TB • Line side terminal barrier accessory snaps-on and installs without the use of tools. • Removable and replaceable identification marker, standard on all c3controls Series 330 Motor Protection Circuit Breakers, simplifies troubleshooting in panels with many devices. • High fault short circuit current rating of 50kA @ 480V provides safety and reliability in high fault applications. • Certified as Manual Motor Controllers Suitable as Motor Disconnects for use in group motor installations in accordance with the NEC (National Electrical Code). • Two versions available – with thermal and magnetic trip elements which provide overload (Trip Class 10) and short circuit protection, and magnetic trip element only for short circuit protection. Use the magnetic trip element only version with Series 320 Overload Relays for overload protection and the other outstanding features of the Series 320. • Single phase sensitivity to protect motors against damaging phase loss conditions. • Designed for optimum performance with Series 300-S09 to 300-S40 Contactors in group motor installations, and can achieve Type 2 coordination in circuits capable of delivering up to 50kA at 460V. • Meets IEC 60947 requirements for starters and circuit breakers and provides isolation functionality. • Modular design accommodates a wide variety of accessories, some of which snap-on without tools, lowering assembly and installation costs. • 18mm wide trip indicating auxiliary contacts can be used to identify the trip cause – overload (1 NO and 1 NC) or short circuit (1 NO and 1 NC), to help determine the type of service/maintenance that may be required. • Compact size – only 45mm (1-49/64”) wide up to 20HP @ 460V (15kW @ 400V) to minimize the amount of panel area required. • The “ON/OFF” manual operator enables individual motor circuits to be easily isolated without having to disconnect all of the circuits in a control panel. • Operators can be padlocked in the “OFF” position (max. one 4.9mm [3/16”] padlock) preventing the motor protection circuit breaker from being turned “ON” when the equipment is being serviced. • Visible trip indication for fast identification of which device tripped in a control panel where multiple motor protection circuit breakers are installed. • IP20 guarded terminals with dual terminal markings prevent accidental contact with live parts. • Combination head terminal screws allow the use of “straight”, “phillips”, or “posidrive” screwdrivers for fast and reliable wiring. • Universal ratings and markings: A, kW, and HP ratings as well as applicable 3rd party certification markings. • Test function to verify the performance of the device and the proper operation of the control circuit and accessories. Section 9 | 8724.775.7926 :: www.c3controls.com

  9. s e r i e s s e r i e s s e r i e s s e r i e s s e r i e s 30 industrial 22 i e c TB i e c / MOTOR PROTECTION CIRCUIT BREAKERS 300 310 reversing s e r i e s s e r i e s s e r i e s s e r i e s 330 CS 620 630 non-reversing motor ProteCtion CirCuit BreakerS TB n e m a Motor Protection circuit Breakers s e r i e s s e r i e s s e r i e s s e r i e s s e r i e s 30 hazardous 22 n e m a 300 miniature 310 miniature While our Series 330 Motor Protection Circuit Breakers are certified as Manual Motor Controllers Suitable as Motor Disconnects, and can be used to manually control individual motors and protect them against overload and short circuit currents, the greatest benefits can be realized by using the Series 330 Motor Protection Circuit Breakers in conjunction with Series 300 Contactors and Series 330 wiring accessories in Group Motor Installations. s e r i e s TB U N I Q U E P R O D U C T F E A T U R E S Space SavingS Control panel sizes can be reduced because the short circuit protection provided by the Series 330 Motor Protection Circuit Breaker enables individual motor branch circuit fuses or circuit breakers and overload relays to be eliminated. Labor SavingS Starter assembly and installation of the starter assemblies in Group Motor Installations is easier and faster with the use of connection modules between the contactor and motor protection circuit breaker and commoning links to conveniently distribute power to multiple starter assemblies. In addition to labor savings, the components look nice too, and provide IP20 protection to guard against accidental contact with live parts. coSt SavingS Smaller size enclosures, reduced wiring, and DIN rail installation all combine to provide a lower cost control panel with superior performance in normal operating conditions as well as in overload or short circuit conditions. Line Side Terminal Barrier DiScover type e Listed as a UL 60947-4-1 Self-protected Combination Manual Motor Controller when accessories trip indicating auxiliary contact (330-STA22S25) and line side terminal barrier (330-LSTBS25) are assembled for circuits capable of delivering up to 50kA @ 460V. For field assembly only. Type E devices provide motor disconnect means, branch short circuit and ground fault protection, motor control and motor overload protection, reducing panel size and eliminating upstream fuses or circuit breakers for a motor circuit. We also offer fully assembled Type E and Type F Direct-On-Line (DOL) Starters, refer to Section 11 Pages 10-17. For Enclosed Type E and Type F assemblies refer to Section 12 Pages 10-17. Trip Indicating Auxiliary Contact Everything under control :: c3controlsSection 9 | 9

  10. s e r i e s s e r i e s s e r i e s s e r i e s s e r i e s 30 industrial 22 i e c TB i e c 300 310 reversing s e r i e s s e r i e s s e r i e s s e r i e s 330 SPECIAL OPERATORS/ External Operating Handles CS 620 630 non-reversing I T ’ S E A S Y T O B U I L D Y O U R O W N O P E R A T I N G H A N D L E s e r i e s s e r i e s s e r i e s s e r i e s s e r i e s 30 hazardous 22 n e m a TB n e m a 300 miniature 310 miniature Simply pick the code number from each of the sections below and combine them to build your part number. Motor Protection Circuit Breaker External Operating Handle 330 - S2 PHG I II III IV V Example: To build one of our most popular External Operating Handles, the part number would be 330 + S2 + PHG + IV + V or 330-S2PHGRY06 s e r i e s TB I. OPERATING HANDLE INSTALLATION IV. OPERATING HANDLE COLOR III. OPERATING HANDLE TYPE CODE DESCRIPTION LIST PHG Round (Type 1, 2, 3, 3R, $15.00 4/4X, 12, 13 and IP65) CODE DESCRIPTION 330 External Operating Handle LIST $45.00 CODE OPERATOR COLOR BEZEL COLOR RY Red Yellow BG Black Grey II. MOTOR PROTECTION CIRCUIT BREAKER FRAME SIZE CODE DESCRIPTION S2 32 Ampere Each operating handle includes a support bracket and coupling to ensure alignment with the motor protection circuit breaker even in deep enclosures. V. OPERATING SHAFT LENGTH CODE DESCRIPTION LIST 06 150mm (5-57/64”) $ 6.30 12 300mm (11-13/16”) $12.60 SCHEDULEF DISCOUNT U N I Q U E P R O D U C T F E A T U R E S c3controls stylish operating handles are easy to install in standard 4-hole panel drilling layouts [36mm x 36mm (1-7/16” x 1-7/16”)]. Operating handles can be installed in enclosures with door thicknesses up to 4mm (5/32”). Rated Type 1, 2, 3, 3R, 4/4X, 12, 13 and IP65 for the most demanding industrial environments. 1. Provide reliable actuation of Series 330 Motor Protection Circuit Breakers and Series 630 Direct-On-Line (DOL) Starters from the outside of the enclosure and can be locked OFF for extra safety. Refer to Section 9 Pages 6 & 7 for our complete selection of Series 330 Motor Protection Circuit Breakers and Section 11 Pages 6 & 7 for Series 630 Direct-On- Line (DOL) Starters. 2. Handles can be padlocked OFF with up to three padlocks. 3. Operating handles with ON/OFF and I/O markings. 4. Door interlock — can only be opened in the OFF position. 5. Positive, reliable actuation of our Series 330 Motor Protection Circuit Breaker is ensured through the rigid steel operating shaft that can be cut to length to fit in enclosures up to 421mm (16-37/64”) deep. NOTE: Motor Protection Circuit Breaker sold separately. mixand matCh any Color Someof our PoPular ConfigurationS: MOTOR PROTECTION CIRCUIT BREAKER EXTERNAL OPERATING HANDLE CATALOG NUMBER OPERATING HANDLE TYPE OPERATING HANDLE COLOR LIST 330-S2PHGRY06 Round Red/Yellow $66.30 330-S2PHGRY12 Round Red/Yellow $72.60 64mm x 64mm (2-17/32” x 2-17/32”) Section 9 | 10724.775.7926 :: www.c3controls.com REVISION 07.2022

  11. s e r i e s s e r i e s s e r i e s s e r i e s s e r i e s 30 industrial 22 i e c TB i e c 300 / ACCESSORIES 310 reversing s e r i e s s e r i e s s e r i e s s e r i e s 330 CS 620 630 non-reversing Motor Protection circuit Breakers FRONT MOUNTED AUXILIARY CONTACTS TB n e m a SIDE MOUNTED AUXILIARY CONTACTS 300 miniature miniature s e r i e s s e r i e s s e r i e s s e r i e s s e r i e s 30 hazardous 22 n e m a 310 L1 1 L2 3 L3 5 13 21 330-SA11S25 33 41 L1 1 L2 3 L3 5 s e r i e s 14 22 T1 2 T2 4 T3 6 TB 34 42 T1 2 T2 4 T3 6 Our front mounted auxiliary contacts do not add depth to the motor protection circuit breaker and installs within its foot print – no extra panel area is required. IP20 guarded terminals protect against accidental contact with live parts. These contacts snap-on and install without the use of tools. 330-SA20S25 L1 1 L2 3 L3 5 33 43 CODE 330-FA11S25 CONTACT CONFIGURATION 1 Normally Open and 1 Normally Closed LIST $21.00 34 44 MOTOR PROTECTION CIRCUIT BREAKER ENCLOSURES T1 2 T2 4 T3 6 Our side mounted auxiliary contacts feature IP20 guarded terminals to protect against accidental contact with live parts. These contacts snap-on to the left side of the motor protection circuit breaker and install without the use of tools. CODE CONTACT CONFIGURATION LIST 330-SA11S25 1 Normally Open and 1 Normally Closed $21.00 330-SA20S25 2 Normally Open $21.00 Our Motor Protection Circuit Breaker Enclosure accessory is a custom fit enclosure design specifically for use with our Series 330 Motor Protection Circuit Breaker providing reliable operation and superior performance. CE certified with an IP55 environmental rating. MOUNTING FOOT KIT The mounting foot kit enables motor protection circuit breakers to be panel mounted instead of installed on a 35mm DIN rail. Available in two frame sizes: Frame Size 1– 55mm internal mounting width allows the assembly of a side mounted auxiliary contact, and Frame Size 2 – 65mm internal mounting width allows the assembly of a shunt release module or undervoltage module. CODE 330-MF1 DESCRIPTION Mounting Foot Kit (2 per pkg.) LIST/PC. $ 1.50 The enclosure has integrated ground and neutral connections, and four (4) standard PG16 knock outs (2 on the top and 2 on the bottom). The operating handle, which is available in two colors, can be padlocked in the “OFF” position with up to three padlocks for extra safety and the security necessary during maintenance activities. SCHEDULEF DISCOUNT FRAME SIZE 1 (55MM INTERNAL MOUNTING WIDTH) DESCRIPTION 330-BABS1RY Motor Protection Circuit Breaker Enclosure with ABS Plastic and Red/Yellow Handle 330-BABS1BG Motor Protection Circuit Breaker Enclosure with ABS Plastic and Black/Grey Handle FRAME SIZE 2 (65MM INTERNAL MOUNTING WIDTH) 330-BABS2RY Motor Protection Circuit Breaker Enclosure with ABS Plastic and Red/Yellow Handle 330-BABS2BG Motor Protection Circuit Breaker Enclosure with ABS Plastic and Black/Grey Handle CODE LIST $63.00 $63.00 $78.00 $78.00 Everything under control :: c3controlsSection 9 | 11

  12. s e r i e s s e r i e s s e r i e s s e r i e s s e r i e s 30 industrial 22 i e c TB i e c 300 310 reversing s e r i e s s e r i e s s e r i e s s e r i e s 330 / ACCESSORIES CS 620 630 non-reversing SHUNT RELEASE MODULES UNDERVOLTAGE RELEASE MODULES s e r i e s s e r i e s s e r i e s s e r i e s s e r i e s 30 hazardous 22 n e m a TB n e m a 300 miniature 310 miniature D1 C1 DC D2 C2 L1 1 L2 3 L3 5 L1 1 L2 3 L3 5 s e r i e s TB T1 2 T2 4 T3 6 T1 2 T2 4 T3 6 The undervoltage release module automatically trips the motor protection circuit breaker when the supply voltage is less than 70 - 35% of the rated volt- age of the undervoltage release module. Undervoltage release modules are ideal to ensure motors do not automatically restart after a power outage when the motor protection circuit breaker is being used by itself as a manual motor controller. Snaps-on and installs on the right side of the motor protection cir- cuit breaker without the use of tools. IP20 guarded terminals to protect against accidental contact with live parts. Wide range of 50/60Hz operating voltages. Can be used in conjunction with front mounted and side mounted auxiliary contacts. The shunt release module enables the motor protection circuit breaker to be turned “OFF” from a remote location. Snaps-on and installs on the right side of the motor protection circuit breaker without the use of tools. IP20 guarded terminals to protect against accidental contact with live parts. Wide range of 50/60Hz operating voltages. Can be used in conjunction with front mounted and side mounted auxiliary contacts. CODE 330-SR25XC 330-SR25XJ 330-SR25XAH 330-SR25XF 330-SR25XQ VOLTAGE RANGE 20 ~ 24V 50/60Hz 40 ~ 48V 50/60Hz 100 ~ 127V 50/60Hz 200 ~ 240V 50/60Hz 365 ~ 440V 50/60Hz LIST $50.00 $50.00 $50.00 $50.00 $50.00 CODE 330-UR25C 330-UR25XC 330-UR25H 330-UR25AG 330-UR25D 330-UR25AH 330-UR25L 330-UR25AJ 330-UR25F 330-UR25P 330-UR25AL 330-UR25Q 330-UR25R 330-UR25T VOLTAGE RANGE 20V 50Hz / 24V 60Hz 24V 50/60Hz 24V 50Hz / 28V 60Hz 95V 50Hz / 110V 60Hz 110V 50Hz / 120V 60Hz 110 ~ 115V 50Hz / 127V 60Hz 180V 50Hz / 208V 60Hz 190V 50Hz / 220V 60Hz 208V 50Hz / 240V 60Hz 230 ~ 240V 50Hz / 277V 60Hz 325V 50Hz / 380V 60Hz 380V 50Hz / 440V 60Hz 400 ~ 415V 50Hz / 480V 60Hz 500V 50Hz / 600V 60Hz LIST $50.00 $50.00 $50.00 $50.00 $50.00 $50.00 $50.00 $50.00 $50.00 $50.00 $50.00 $50.00 $50.00 $50.00 TRIP INDICATING AUXILIARY CONTACTS LINE SIDE TERMINAL BARRIER The trip indicating auxiliary contact module includes Overload Contacts and Short Circuit Contacts. When an overload trip occurs the Overload Contacts change state. When a short circuit trip occurs, the Overload Contacts and Short Circuit Contacts change state. In addition to the electrical contacts, the trip indicating auxiliary contact module includes a mechanical trip indication – the blue button protrudes from the module after a short circuit trip. The trip indicating contact module can be field installed without the use of tools on Series 330-T25S and 330-M25S Motor Protection Circuit Breakers and can be used in conjunction with standard front mounted (330-FA) and side mounted (330-SA) auxiliary contacts. NOTE: The Trip Indicating Auxiliary Contact and the Line Side Terminal Barrier are required to achieve Type E construction with a Series 330-T25S device. The line side terminal barrier provides increased electrical clearances to comply with the UL 60947-4-1 Self-Protected Combination Motor Controller (Type E) requirements. The terminal barrier can be field installed on Series 330-T25S and 330-M25S Motor Protection Circuit Breakers. NOTE: The Line Side Terminal Barrier and the Trip Indicating Auxiliary Contact are required to achieve Type E construction with a Series 330-T25S device. CODE 330-STA22S25 DESCRIPTION 18mm Wide - Left Side Mounted Trip Indicating Auxiliary Contact (1 NO and 1 NC overload and 1 NO and 1 NC short circuit) LIST18 $57.00 CODE 330-LSTBS25 DESCRIPTION Line Side Terminal Barrier LIST1 $30.75 SCHEDULEF DISCOUNT Section 9 | 12724.775.7926 :: www.c3controls.com

  13. s e r i e s s e r i e s s e r i e s s e r i e s s e r i e s 30 industrial 22 i e c TB i e c 300 / ACCESSORIES 310 reversing s e r i e s s e r i e s s e r i e s s e r i e s 330 CS 620 630 non-reversing Motor Protection circuit Breakers COMMONING LINKS TB n e m a ADJUSTMENT SCALE COVER 300 miniature miniature s e r i e s s e r i e s s e r i e s s e r i e s s e r i e s 30 hazardous 22 n e m a 310 means of distributing 3-phase power to a group of motor protection circuits. 45mm spacing commoning links are for use with motor protection circuit breakers without auxiliary contact modules or with a front mounted auxiliary contact module (330-FA11S25). 54mm spacing commoning links are for use with motor protection circuit breakers with a side mounted auxiliary contact module (330-SA11S25 or 330-SA20S25). IP20 construction to guard against accidental contact with live parts. Used in conjunction with 330-FT1S2 Feeder Module. Commoning links provide a convenient The adjustment scale cover prevents inadver- tent or unauthorized adjustment of the full load current dial setting of the motor protection circuit breaker. s e r i e s TB CODE 330-SCS2 DESCRIPTION Adjustment Scale Cover (5 per pkg.) LIST/PC. $ 5.50 CODE FOR USE WITH CONTINUOUS CURRENT RATING LENGTH LIST SHROUD FOR UNUSED COMMONING LINK TERMINALS 45MM SPACING 330-CL452S2 330-CL453S2 330-CL454S2 330-CL455S2 2 Motor Protection Circuit Breakers 3 Motor Protection Circuit Breakers 4 Motor Protection Circuit Breakers 5 Motor Protection Circuit Breakers 63A 91mm $34.00 The highly visible yellow terminal shroud with the hazard symbol is for covering unused terminals of the 330-CL commoning links. Use of the shroud insulates the unused terminals and enables the easy installation of additional motor protection circuit breakers in the future. 63A 136mm $40.00 63A 181mm $45.00 63A 226mm $48.00 54MM SPACING 330-CL542S2 330-CL543S2 330-CL544S2 330-CL545S2 2 Motor Protection Circuit Breakers 3 Motor Protection Circuit Breakers 4 Motor Protection Circuit Breakers 5 Motor Protection Circuit Breakers 63A 100mm $35.00 CODE 330-CLSS2 DESCRIPTION Shroud LIST $11.00 63A 154mm $41.00 63A 208mm $48.00 63A 262mm $51.00 CIRCUIT BREAKER – CONTACTOR LINK MODULE The circuit breaker – contactor link module provides a mechanical and electrical linkage between a motor protection circuit breaker and a Series 300 Contactor. The circuit breaker – contactor link module makes starter assembly easy and enables the starter assembly to be installed on a single or two 35mm DIN rails. FEEDER TERMINAL FOR COMMONING LINK TERMINALS The feeder terminal accepts the main branch circuit conductors and distributes power to the 330-CL Commoning Links. The feeder terminal overlaps the commoning link when installed. IP20 guarded terminals to protect against accidental contact with live parts. Continuous current rating: 63A. CODE 330-CMS216 Series 300-M07 to 300-M16 AC or DC Operated Contactors 330-CMS225A Series 300-S09 to 300-S25 AC Operated Contactors 330-CMS225D Series 300-S09 to 300-S25 DC Operated Contactors 330-CMS240A Series 300-S32 to 300-S40 AC Operated Contactors 330-CMS240D Series 300-S32 to 300-S40 DC Operated Contactors FOR USE WITH LIST18 $26.00 CODE 330-FT1S2 DESCRIPTION Feeder Terminal LIST1 $39.00 $26.00 $26.00 $26.00 $26.00 SCHEDULEF DISCOUNT Everything under control :: c3controlsSection 9 | 13

  14. s e r i e s s e r i e s s e r i e s s e r i e s s e r i e s 30 industrial 22 i e c TB i e c 300 310 reversing s e r i e s s e r i e s s e r i e s s e r i e s 330 SPECIFICATIONS/ CS 620 630 non-reversing SPeCifiCationS: s e r i e s s e r i e s s e r i e s s e r i e s s e r i e s 30 hazardous 22 n e m a TB n e m a 300 miniature 310 miniature ELECTRICAL SPECIFICATIONS CAT. NO. 330-T25S**** AND 330-M25S**** 2D10 2D16 2D25 2D40 2C16 2C25 2C40 2C63 2D63 2U10 2U16 2U20 2U25 2U32 ELECTRICAL GENERAL Rated Operating Current Current Setting Range1 Magnetic Trip Current Operating Frequency Power Dissipation per pole Electrical Life Maximum Operating Rate s e r i e s TB UNITS A A A Hz W Ops. Ops./Hr. 0.16 0.10 ~ 0.16 ~ 0.25 ~ 0.40 ~ 0.63 ~ 0.16 0.25 0.40 2.1 3.3 5.2 5 5 5 0.25 0.40 0.63 1.0 1.6 1.0 ~ 1.6 21 6 2.5 1.6 ~ 2.5 ~ 2.5 33 50/60 6 100,000 15 4.0 6.3 4.0 ~ 6.3 82 10 6.3 ~ 10 130 16 10 ~ 16 208 20 16 ~ 20 260 25 20 ~ 25 325 32 25 ~ 32 416 0.63 8.2 5 1.0 13 6 4.0 52 6 6 7 8 8 8 8 ELECTRICAL UL/CSA APPLICATIONS MAIN CIRCUITS Rated Operating Voltage, Ue RATED 1 PHASE OPERATING POWER, Pe 115V 230V RATED 3 PHASE OPERATING POWER, Pe 200V 230V 460V 575V MANUAL MOTOR CONTROLLER, MAXIMUM SHORT CIRCUIT CURRENT @ 480V @ 600V MANUAL MOTOR CONTROLLER IN GROUP INSTALLATIONS, MAXIMUM SHORT CIRCUIT CURRENT @ 480V Maximum Fuse2 @ 600V Maximum Fuse2 MANUAL MOTOR CONTROLLER SUITABLE FOR TAP CONDUCTOR PROTECTION IN GROUP INSTALLATIONS, MAXIMUM SHORT CIRCUIT CURRENT @ 480V Maximum Fuse 2 @ 600V Maximum Fuse 2 VAC HP HP HP HP HP HP 600 1/8 1/3 3/4 1 — — — — — — — — — — — — — — — — — — — — — — — 1/4 — — — — 1/2 1/2 — 1/10 1/4 1/3 3/4 1 — 1/6 1/2 1/2 1-1/2 2 1-1/2 3 1/4 3/4 1-1/2 1-1/2 3 5 1/2 1-1/2 1 3 1-1/2 3 2 3 — 5 3 3 5 5 10 15 5 7-1/2 7-1/2 15 20 10 10 20 25 7-1/2 15 20 7-1/2 10 50 25 kA kA 50 25 50 25 50 25 50 25 50 25 50 25 50 25 50 25 50 25 50 25 50 25 50 25 50 25 50 450 25 450 kA A kA A 50 450 25 450 50 450 25 450 50 450 25 450 50 450 25 450 50 450 25 450 50 450 25 450 50 450 25 450 50 450 25 450 50 450 25 450 50 450 25 450 50 450 25 450 50 450 25 450 50 450 25 450 50 kA A kA A 50 450 25 450 50 450 25 450 50 450 25 450 50 450 25 450 50 450 25 450 50 450 25 450 50 450 450 25 450 450 50 450 25 450 50 450 25 450 50 450 25 450 50 450 25 450 50 450 25 450 50 450 25 450 25 1 330-T25S only. 2 Not to exceed the maximum fuse/circuit breaker size, per the National Electrical Code. NOTE: **** Represents the current and power ratings code. Refer to pages 6 & 7. Section 9 | 14724.775.7926 :: www.c3controls.com

  15. s e r i e s s e r i e s s e r i e s s e r i e s s e r i e s 30 industrial 22 i e c TB i e c 300 / SPECIFICATIONS 310 reversing s e r i e s s e r i e s s e r i e s s e r i e s 330 CS 620 630 non-reversing Motor Protection circuit Breakers ELECTRICAL, MECHANICAL & ENVIRONMENTAL SPECIFICATIONS s e r i e s s e r i e s s e r i e s s e r i e s s e r i e s 30 hazardous 22 n e m a TB n e m a CAT. NO. 330-T25S**** AND 330-M25**** 2D16 2D25 2D40 300 miniature 2D63 310 miniature 2C16 2C25 2C40 2C63 2D10 2U10 2U16 2U20 2U25 2U32 ELECTRICAL IEC APPLICATIONS MAIN CIRCUITS Rated Insulation Voltage, Ui Rated Impulse Voltage, Uimp Rated Operating Voltage, Ue RATED 3 PHASE AC-3 OPERATING POWER, Pe 230V 400/415V 500V 690V ULTIMATE SHORT CIRCUIT BREAKING CAPACITY, Icu 230V 400/415V 440V 500V 690V RATED SERVICE SHORT CIRCUIT BREAKING CAPACITY, Ics 230V 400/415V 440V 500V 690V BACK-UP FUSES, gG/gL3 230V 400/415V 400V 500V 690V MECHANICAL Mechanical Life ENVIRONMENTAL Ambient Operating Temperature Ambient Storage Temperature Altitude Shock UNITS s e r i e s TB V kV VAC 690 6 690 kW kW kW kW — — — 0.06 — 0.06 0.06 0.12 — 0.09 0.12 0.18 0.06 0.12 0.25 0.25 0.12 0.25 0.37 0.55 0.18 0.55 0.75 1.1 0.37 0.75 1.1 1.5 0.75 1.5 2.2 3 1.1 2.2 3 4 2.2 4 4 7.5 3.7 7.5 9 12.5 3.7 9 12.5 15 5.5 12.5 15 22 7.5 15 18.5 30 kA kA kA kA kA 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 8 100 100 100 100 6 100 100 100 100 6 100 50 50 42 6 100 50 50 10 4 100 50 50 10 4 100 50 50 10 4 100 50 50 10 4 kA kA kA kA kA A A A A A 100 100 100 100 100 4 4 4 4 4 100 100 100 100 100 4 4 4 4 4 100 100 100 100 100 4 4 4 4 4 100 100 100 100 100 4 100 100 100 100 100 4 4 4 4 4 100 25 100 100 100 4 4 4 4 4 100 25 100 100 8 4 4 4 4 25 100 25 100 100 3 4 4 4 4 32 100 25 100 100 3 4 4 4 4 50 100 25 25 21 3 4 4 80 63 50 100 25 15 8 3 4 100 80 80 63 100 25 15 8 3 4 125 80 80 63 100 25 15 8 3 100 25 15 8 3 4 125 100 80 63 4 125 100 80 63 4 4 4 4 Ops. 100,000 °C / °F °C / °F m / ft. g -20 to 60 / -4 to 140 -50 to 80 / 58 to 176 2,000 / 6,562 15 3 Back-up fuse required only if Icc > Icu. 4 No back-up fuse required. NOTE: **** Represents the current and power ratings code. Refer to pages 6 & 7. Everything under control :: c3controlsSection 9 | 15

  16. s e r i e s s e r i e s s e r i e s s e r i e s s e r i e s 30 industrial 22 i e c TB i e c 300 310 reversing s e r i e s s e r i e s s e r i e s s e r i e s 330 SPECIFICATIONS/ CS 620 630 non-reversing CONSTRUCTION SPECIFICATIONS s e r i e s s e r i e s s e r i e s s e r i e s s e r i e s 30 hazardous 22 n e m a TB n e m a 300 miniature 310 miniature CAT. NO. 330-T25S**** AND 330-M25S**** 2D10 2D16 2D25 2C16 2C25 2C40 2C63 2D40 2D63 2U10 2U16 2U20 2U25 2U32 CONSTRUCTION Number of Poles Trip Class Over Voltage Category Pollution Degree INGRESS PROTECTION Main Circuit Terminals Control Circuit Terminals WEIGHT kg lbs CONDUCTOR SIZE UL/CSA Solid Stranded Fine Stranded TERMINAL TORQUE UNITS ul ul ul ul 3 s e r i e s TB 10 III 3 IP20 IP20 0.32 0.7 AWG mm2 mm2 mm2 Nm Lb-in. 2 x 14 ~ 10 2 x 1 ~ 2.5 2 x 1 ~ 2.5 2 x 1 ~ 2.5 2 ~ 2.5 17.7 ~ 22.1 ROHS COMPLIANCE For RoHS compliance documentation by product, refer to www.c3controls.com NOTE: **** Represents the current and power ratings code. Refer to pages 6 & 7. TYPE 2 COORDINATION SPECIFICATIONS1 MOTOR PROTECTION CIRCUIT BREAKER MAXIMUM FUSE OR CIRCUIT BREAKER (AMP)2 450A 450A 450A 450A 450A 450A 450A 450A 450A 450A 450A 450A 450A 450A WITH THERMAL AND MAGNETIC TRIP ELEMENTS 330-T25S2C16 330-T25S2C25 330-T25S2C40 330-T25S2C63 330-T25S2D10 330-T25S2D16 330-T25S2D25 330-T25S2D40 330-T25S2D63 330-T25S2U10 330-T25S2U16 330-T25S2U20 330-T25S2U25 330-T25S2U32 WITH MAGNETIC TRIP ELEMENT ONLY 330-M25S2C16 330-M25S2C25 330-M25S2C40 330-M25S2C63 330-M25S2D10 330-M25S2D16 330-M25S2D25 330-M25S2D40 330-M25S2D63 330-M25S2U10 330-M25S2U16 330-M25S2U20 330-M25S2U25 330-M25S2U32 MAXIMUM SHORT CIRCUIT CURRENT @ 480V 50kA 50kA 50kA 50kA 50kA 50kA 50kA 50kA 50kA 50kA 50kA 50kA 50kA 50kA CONTACTOR3 300-S09 300-S09 300-S09 300-S09 300-S09 300-S09 300-S09 300-S09 300-S09 300-S09 300-S12 300-S18 300-S25 300-S32 1 Type 2 Coordination requires that, under short-circuit conditions, the contactor or starter shall cause no danger to persons or installation and shall be suitable for further use. The risk of contact welding is recognized, in which case the manufacturer shall indicate the measures to be taken with regard to the maintenance of the equipment. 2 Per the National Electrical Code. 3 Minimum size contactor shown. Type 2 Coordination can also be achieved with a larger size contactor. For example: a 300-S12 instead of a 300-S09, or a 300-S18 instead of a 300-S12. Section 9 | 16724.775.7926 :: www.c3controls.com

  17. s e r i e s s e r i e s s e r i e s s e r i e s s e r i e s 30 industrial 22 i e c TB i e c 300 / SPECIFICATIONS 310 reversing s e r i e s s e r i e s s e r i e s s e r i e s 330 CS 620 630 non-reversing Motor Protection circuit Breakers AUXILIARY CONTACTS SPECIFICATIONS ELECTRICAL GENERAL Minimum Switching Capacity ELECTRICAL UL/CSA APPLICATIONS Rated Operating Voltage, Ue PILOT DUTY RATING AC DC General Use ELECTRICAL IEC APPLICATIONS Rated Insulation Voltage, Ui Rated Operating Voltage, Ue RATED AC-15 OPERATING CURRENT, Ie 24V 230V 380-415V 440-500V RATED DC-13 OPERATING CURRENT, Ie 24V 60V 110V 220V Short Circuit Protection with Fuses (gG/gL) CONSTRUCTION Over Voltage Category Pollution Degree INGRESS PROTECTION Control Circuit Terminals WEIGHT CONDUCTOR SIZE UL/CSA Solid Stranded Fine Stranded Terminal Torque s e r i e s s e r i e s s e r i e s s e r i e s s e r i e s 30 hazardous 22 n e m a TB n e m a 300 miniature FRONT MOUNTED AUXILIARY CONTACT 330-FA 310 miniature SIDE MOUNTED AUXILIARY CONTACT 330-SA UNITS A V V V A A A A A A A A 5mA @ 17V 600 5mA @ 17V s e r i e s TB 300 50/60 A600 Q600 10A @ 600V 690 690 6 4 3 2 2 0.5 0.5 0.25 C300 R300 2.5A @ 240V 250 250 2 0.5 — — 1 0.15 — — A ul ul ul g oz. AWG mm2 mm2 mm2 Nm Lb-in. 10 III 3 IP20 20 0.71 10 III 3 IP20 38 1.34 2 x 18 ~ 14 2 x 0.5 ~ 2.5 2 x 0.5 ~ 2.5 2 x 0.5 ~ 2.5 1 ~ 1.25 8.9 ~ 11.1 2 x 18 ~ 14 2 x 0.5 ~ 2.5 2 x 0.5 ~ 2.5 2 x 0.5 ~ 2.5 1 ~ 1.25 8.9 ~ 11.1 Everything under control :: c3controlsSection 9 | 17

  18. s e r i e s s e r i e s s e r i e s s e r i e s s e r i e s 30 industrial 22 i e c TB i e c 300 310 reversing s e r i e s s e r i e s s e r i e s s e r i e s 330 SPECIFICATIONS/ CS 620 630 non-reversing RELEASE MODULES SPECIFICATIONS UNDERVOLTAGE RELEASE MODULES UNDER VOLTAGE RELEASE MODULES SHUNT RELEASE MODULES 330-UR s e r i e s s e r i e s s e r i e s s e r i e s s e r i e s 30 hazardous 22 n e m a TB n e m a 300 miniature 310 miniature 330-SR ELECTRICAL Rated Operating Voltage, Ue V 24 ~ 600 24 ~ 440 Operating Range ul — 70 ~ 110% Pick-Up Voltage ul 85 ~ 110% — Drop-Out Voltage ul 70 ~ 35% — POWER CONSUMPTION Pick-Up VA — 20.2 Sealed VA — 7.2 UNITS s e r i e s TB CONSTRUCTION INGRESS PROTECTION Control Circuit Terminals ul IP20 IP20 WEIGHT g 115 115 oz. 4.1 4.1 CONDUCTOR SIZE UL/CSA AWG 2 x 18 ~ 14 Solid mm2 2 x 0.5 ~ 2.5 Stranded mm2 2 x 0.5 ~ 2.5 Fine Stranded mm2 Terminal Torque Nm Lb-in. 2 x 18 ~ 14 2 x 0.5 ~ 2.5 2 x 0.5 ~ 2.5 2 x 0.5 ~ 2.5 1 ~ 1.25 8.9 ~ 11.1 2 x 0.5 ~ 2.5 1 ~ 1.25 8.9 ~ 11.1 Section 9 | 18724.775.7926 :: www.c3controls.com

  19. s e r i e s s e r i e s s e r i e s s e r i e s s e r i e s 30 industrial 22 i e c TB i e c / CIRCUIT DIAGRAMS 300 reversing 310 s e r i e s s e r i e s s e r i e s s e r i e s 330 CS 620 630 non-reversing Motor Protection circuit Breakers C I R C U I T D I A G R A M S s e r i e s s e r i e s s e r i e s s e r i e s s e r i e s 30 hazardous 22 n e m a TB n e m a 300 miniature 310 miniature 1 PhaSe – 1 Pole 1 PhaSe – 2 Pole 3 PhaSe – 3 Pole L2 3 L3 L1 1 5 L2 3 L3 L1 1 TB 5 L2 3 L3 L1 1 5 s e r i e s T3 6 T1 2 T2 4 T3 6 T1 2 T2 4 T3 6 T1 2 T2 4 traditional multi-motor aPPliCation grouP motor aPPliCation Self-ProteCted motor aPPliCation Non-Fused Disconnect Switch Fusible Disconnect Switch or Molded Case Circuit Breaker Series 330 Motor Protection Circuit Breaker Fuses or Molded Case Circuit Breakers Series 330 Motor Protection Circuit Breakers Series 300 Contactors Series 300 Contactor Series 320 Overload Relays Series 300 Contactors M 3~ M 3~ M 3~ M 3~ M 3~ M 3~ M 3~ M 3~ M 3~ M 3~ 330-t25S & 300-S 330-m25S & 300-S Everything under control :: c3controlsSection 9 | 19

  20. s e r i e s s e r i e s s e r i e s s e r i e s s e r i e s 30 industrial 22 i e c TB i e c 300 310 reversing s e r i e s s e r i e s s e r i e s s e r i e s 330 TRIP CHARACTERISTICS/ CS 620 630 non-reversing T R I P C H A R A C T E R I S T I C S TRIP CHARACTERISTICS s e r i e s s e r i e s s e r i e s s e r i e s s e r i e s 30 hazardous 22 n e m a TB n e m a 300 miniature 310 miniature 330-m25S* 330-t25S 2h 2h 100 60 40 20 100 60 40 20 s e r i e s TB minute minute 10 10 6 4 2 6 4 2 1 1 40 20 10 40 20 10 3-phase second second 2-phase 6 4 2 6 4 2 1 1 600 400 200 100 60 40 20 10 600 400 200 100 60 40 20 10 milisecond milisecond 6 4 6 4 1 1.5 2 3 4 5 6 7 8 910 15 20 30 1 1.5 2 3 4 5 6 7 8 910 15 20 30 Multiple of Operating Current (Ie) Multiple of Operating Current (Ie) *NOTE: Protection below short circuit rating (12x Full Load Current) is provided by an overload protective device (ex. Series 320 or similar function built into the motor). OPERATING POSITION Section 9 | 20724.775.7926 :: www.c3controls.com

  21. s e r i e s s e r i e s s e r i e s s e r i e s s e r i e s 30 industrial 22 i e c TB i e c 300 / DIMENSIONS 310 reversing s e r i e s s e r i e s s e r i e s s e r i e s 330 CS 620 630 non-reversing Motor Protection circuit Breakers MOTOR PROTECTION CIRCUIT BREAKER TB n e m a s e r i e s s e r i e s s e r i e s s e r i e s s e r i e s 30 hazardous 22 n e m a 300 miniature 310 miniature ø4.8mm (3/16”) 45mm (1-49/64”) 30mm (1-3/16”) 95.9mm (3-25/32”) s e r i e s TB 118.9mm (4-11/16”) 97.3mm (3-53/64”) 107.9mm (4-1/4”) TYPE E CONSTRUCTION – MOTOR PROTECTION CIRCUIT BREAKER 18mm (45/64”) 9mm (23/64”) 45mm (1-49/64”) 95.9mm (3-25/32”) 30mm (1-3/16”) ø4.8mm (3/16”) Drawing released for catalog pages and models only DESCRIPTION 04/11/2014 DATE 1 DH REV CHGD BY APVD BY REVISION HISTORY controls ® D. Hehman D. Hehman 32A MPCB Assembly; Mounting Foot (Qty: 4) 108.8mm (4-9/32”) 119.6mm (4-45/64”) 107.9mm (4-1/4”) 4/9/2014 12M10002G01 1:1 1 C SIDE MOUNTED AUXILIARY NOT REQUIRED FOR TYPE E CONSTRUCTION MOTOR PROTECTION CIRCUIT BREAKER WITH SIDE MOUNTED AUXILIARY, FRONT MOUNTED AUXILIARY, SHUNT RELEASE AND UNDERVOLTAGE RELEASE MODULES 9mm (23/64”) 45mm (1-49/64”) 18mm (45/64”) 30mm (1-3/16”) 95.9mm (3-25/32”) ø4.8mm (3/16”) 107.9mm (4-1/4”) 118.9mm (4-11/16”) 97.3mm (3-53/64”) Everything under control :: c3controlsSection 9 | 21 Drawing released for catalog pages and models only DESCRIPTION 04/11/2014 DATE DH 1 REV CHGD BY APVD BY REVISION HISTORY controls ® D. Hehman 32A MPCB Assembly; Mounting Foot (Qty: 4), Side Mounted Auxiliary, Front Mounted Auxiliary, Shunt/Undervoltage Release Module D. Hehman 4/9/2014 12M10004G01 1:1 C 1

  22. PANEL LAYOUT s e r i e s s e r i e s s e r i e s s e r i e s s e r i e s 30 industrial 22 i e c TB i e c 300 310 reversing s e r i e s s e r i e s s e r i e s s e r i e s 64mm (2-33/64”) 330 DIMENSIONS/ CS 620 630 NOTE: The center of the handle is 12mm (31/64”) below the mounting center of the Series 330 Operator. 36mm (1-27/64”) non-reversing ø5mm (ø11/64”) ON OFF 12mm (31/64”) 36mm (1-27/64”) E X T E R N A L O P E R A T I N G H A N D L E 64mm (2-33/64”) TRIP CHARACTERISTICS s e r i e s s e r i e s s e r i e s s e r i e s s e r i e s 30 hazardous 22 n e m a TB n e m a 300 miniature 310 miniature ø12mm (ø31/64”) Center Line of Series 330 Operator PANEL MOUNTING PANEL LAYOUT ø4.8mm (3/16”) 30mm (1-3/16”) PANEL MOUNTING 35mm DIN RAIL MOUNTING 64mm (2-33/64”) NOTE: The center of the handle is 12mm (31/64”) below the mounting center of the Series 330 Operator. s e r i e s TB 36mm (1-27/64”) ø5mm (ø11/64”) 30mm (1-3/16”) ø5mm (ø11/64”) ON OFF 12mm (31/64”) 36mm (1-27/64”) 104mm (4-7/64”) ø12mm (ø31/64”) 107.9mm (4-1/4”) 64mm (2-33/64”) Center Line of Series 330 Operator SHAFT CUTTING INSTRUCTIONS ED SL = ED - DD - 8.4mm (21/64”)* ED = Enclosure Depth E PT S = E - D - K* PT = Panel Thickness DD = Device Depth SL = Shaft Length SK = Shaft Constant = 8.4mm (1/3”) E = Enclosure Depth P = Panel Thickness D = Device Depth S = Shaft Length K = Shaft Constant (27mm [1.06"]) P 12mm (31/64”) Minimum Panel Thickness (PT) = 1mm (3/64”) Maximum Panel Thickness (PT) = 4mm (5/32”) Minimum Panel Thickness (P) = 1mm (0.04”) Maximum Panel Thickness (P) = 4mm (0.16”) Minimum Enclosure Depth (E) = 177mm (6.97”) Maximum Enclosure Depth (E) = 421mm (16.57”) Minimum Enclosure Depth (ED) = 58mm (2-9/32”) + 8.4mm (21/64”) + DD Maximum Enclosure Depth (ED) = 158mm (6-7/32”) + 8.4mm (21/64”) + DD 12 [.476] DD *NOTE: Subtract an additional 2.3mm (0.09”) when mounting the Series 330 Motor Protection Circuit Breaker onto a DIN rail. SL SK D S K *NOTE: Subtract an additional 2.3mm (3/32”) when mounting the motor protection circuit breaker onto a DIN rail. MOTOR PROTECTION CIRCUIT BREAKER ENCLOSURES frame Size 1 frame Size 2 12.1 mm (15/32") 92.5 mm (3-21/32") 12.1 mm (15/32") 115.0 mm (4-17/32") 154.1 mm (6-1/16") 154.1 mm (6-1/16") 70.0 mm 70.0 mm (2-3/4") (2-3/4") 175.0 mm (6-29/32") 175.0 mm (6-29/32") 70.0 mm (2-3/4") 70.0 mm (2-3/4") 80.0 mm (3-1/8") (2-9/16") 65.0 mm 80.0 mm (3-1/8") (2-9/16") 65.0 mm (2-9/16") 65.0 mm 80.0 mm (3-1/8") (2-9/16") 65.0 mm 80.0 mm (3-1/8") 22.0 mm (7/8") 22.0 mm (7/8") 28.0 mm (1-3/32") 37.5 mm (1-15/32") 37.5 mm (1-15/32") 28.0 mm (1-3/32") 35.0 mm (1-3/8") 24.0 mm (15/16") 24.0 mm (15/16") 35.0 mm (1-3/8") Section 9 | 22724.775.7926 :: www.c3controls.com REVISION 06.2022

  23. s e r i e s s e r i e s s e r i e s s e r i e s s e r i e s 30 industrial 22 i e c TB i e c 300 / DIMENSIONS 310 reversing s e r i e s s e r i e s s e r i e s s e r i e s 330 CS 620 630 non-reversing Motor Protection circuit Breakers COMMONING LINKS AND FEEDER TERMINAL TB n e m a s e r i e s s e r i e s s e r i e s s e r i e s s e r i e s 30 hazardous 22 n e m a 300 miniature 310 miniature 330-t25S and 330-m25S with Commoning linkS (330-Cl45*S2 and 330-Cl54*S2) and feeder terminal (330-ft1) 57.4mm (2-17/64") 22mm (55/64”) COMMONING LINKS FOR USE WITH 45MM SPACING 2 Motor Protection Circuit Breakers 3 Motor Protection Circuit Breakers 4 Motor Protection Circuit Breakers 5 Motor Protection Circuit Breakers 54MM SPACING 2 Motor Protection Circuit Breakers 3 Motor Protection Circuit Breakers 4 Motor Protection Circuit Breakers 5 Motor Protection Circuit Breakers 30mm (1-11/64”) CODE A (LENGTH) s e r i e s TB 330-CL452 330-CL453 330-CL454 330-CL455 91mm (3-37/64”) 136mm (5-23/64”) 23mm (29/32”) 54mm (2-1/8”) 181mm (7-1/8”) A 123mm (4-27/32”) 226mm (8-29/32”) 330-CL542 330-CL543 330-CL544 330-CL545 100mm (3-15/16”) 23mm (29/32”) 45mm (1-49/64”) A 154mm (6-1/16”) 44mm (1-47/64”) 24.2mm (61/64”) 208mm (8-3/16”) 262mm (10-5/16”) 25mm (63/64”) 33.5mm (1-5/16”) 11mm (7/16”) NOTE: *Represents the code for the number of motor protection circuit breakers. Refer to the chart above or page 13. V I S I T W W W . C 3 C O N T R O L S . C O M T O D O W N L O A D C A D D R A W I N G S Everything under control :: c3controlsSection 9 | 23

More Related