diphoton met analysis update n.
Download
Skip this Video
Loading SlideShow in 5 Seconds..
Diphoton + MET Analysis Update PowerPoint Presentation
Download Presentation
Diphoton + MET Analysis Update

Loading in 2 Seconds...

play fullscreen
1 / 18
brooke-mueller

Diphoton + MET Analysis Update - PowerPoint PPT Presentation

100 Views
Download Presentation
Diphoton + MET Analysis Update
An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.

- - - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - - -
Presentation Transcript

  1. Diphoton + MET Analysis Update Bruce Schumm UC Santa Cruz / SCIPP 9 April 2013 JET-MET Meeting

  2. In January, we were preparing to unblind our two strong-production analyses Many studies had been done and we were addressing finer points in assuring that backgrounds were understood We were then asked to move to p1328 EGamma10NoTauLooseRef had been chosen for p1181 after substantial study Studies needed to be redone for p1328; several questions raised that we have been exploring since then This update will be solely on our MET studies & status since then.

  3. MET performance of new variables, vs. old: DATA • Points are p1181 EGamma10NoTauLooseRef (prior chosen variable) • LocHadTopo did not change between p1181 and p1328 Numbers of events in last two bins Tight-tight (signal) sample, blinded for MET>100

  4. MET performance of new variables, vs. old: MC • Gamma-gamma MC; 18 GeV filter • Limited tails for LocHadTopo (more stats on way…) p1328 Others LocHadTopo p1181

  5. Control Samples: MC • Signal (gg,GG) is from gamma-gamma MC • Control samples (QCDtg, QCDg) from gamma-jet MC • Control photon in control sample NOT ISOLATED Proposed nominal control sample

  6. Control Samples: MC • EGamma10NoTauLoose in p1328

  7. Control Samples: MC • LocHadTopo in p1328

  8. Control Samples: MC • MetRefFinal in p1328

  9. Control Samples: DATA • QCDg • Significant change between p1181 and p1328 p1181 p1328 P1328 MetRefFinal

  10. Control Samples: DATA • QCDtg • Significant change between p1181 and p1328, although not as much as for QCDg

  11. Control Samples: DATA (shows higher MET) • EGamma10NoTauLoose in p1328 Good proxy for signal? Signal (blinded)

  12. Control Samples: DATA (shows higher MET) • LocHadTopo in p1328

  13. Control Samples: DATA (shows higher MET) • MetRefFinal in p1328 • Again QCDtg looks OK but QCDg not as good

  14. CONCLUSIONS/OUTLOOK FOR p1328 • Hope to get more statistics for gamma-gamma MC by raising filtering thresholds; being generated now. But for now: • LocHadTopo • Has smallest tails for tight-tight sample • All control samples look very good (including high-statistics QCDg-noIso, which was used for 7 TeV) • MetRefFinal • Bigger tails for tight-tight sample • QCDtg-noIso and QCDg-iso control samples look OK • EGamma10NoTauLoose • Bigger tails • No acceptable control samples