1 / 15

The Volpe Firm, Inc.

Advanced Troubleshooting in a DOCSIS 3.0 Plant. Brady Volpe Walter Miller. The Volpe Firm, Inc. . JDSU . Advanced Field Troubleshooting. Why is DOCSIS 3 Troubleshooting Different? Multiple Bonded Channels Downstream Not that different. The channels are constant carrier

brant
Download Presentation

The Volpe Firm, Inc.

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Advanced Troubleshooting in a • DOCSIS 3.0 Plant • Brady Volpe Walter Miller The Volpe Firm, Inc. JDSU

  2. Advanced Field Troubleshooting • Why is DOCSIS 3 Troubleshooting Different? • Multiple Bonded Channels • Downstream • Not that different. • The channels are constant carrier • Multiple downstream channels have been around forever • Upstream • Still most vulnerable portion of plant • The modem is no longer limited to a single upstream transmit path • In some ways this is actually easier with DOCSIS 3.0

  3. Partial Service • One or more upstream or downstream channels become unusable • Partial service does not necessarily impact subscriber • Can be viewed as an advantage from a network operations POV • Hard to detect after CM registration • If the channel is down when the modem registers: • Will not cause performance issues, unless US is at maximum utilization • The errors for the “down” channel(s) are reported to the CMTS in the REG-ACK • D3.0 test equipment will show fewer channels bonded that expected • If the channel is down after the modem registers: • Data loss until CMTS realizes that Ch is unusable (~1 min – 15xT3 timeouts) • T4 Timeout > CMTS stops granting transmit opportunities • CMTS vendors handle re-acquisition differently (it is a SHOULD requirement)

  4. Impaired Service • One or more channels are experiencing RF channel impairments • Presence of codeword errors is one way to identify an impaired channel • Channel impaired when ranging ok, but data becomes corrupted • What would we say about impaired service: • Impaired service impacts subscriber performance and quality of experience (QoE) • It is easy to detect impaired service • Throughput can be a good test for this, but not in all cases • High volume Packetloss is the most effective test to detect impaired service • Customer complaints likely to generate a ticket: • VoIP issues (robo-voice, dropped words, dialing issues, dropped calls, etc.) • VOD – cannot retrieve movie, cannot interact with Guide • Gaming issues – latency, interactivity issues • VPN issues – calling, two-way video, desktop sharing, VPN dropping, etc. • File Sharing/Transfer/FTP Upstream – very slow upstream transfers

  5. Advanced Field Troubleshooting • Evaluating the Downstream Quality • Use traditional PHY attributes • MER • BER • DQI • Use traditional Service Layer attributes • PacketLoss • Throughput

  6. Advanced Field Troubleshooting • Evaluating the Upstream Quality • To troubleshoot the field, • look in the headend!

  7. Partial Service Troubleshooting • Partial Service manifests as missing channels. • Does not demonstrate Packetloss or Throughput

  8. Impaired Service Troubleshooting • An impaired service may or may not exhibit codeword errors and packetloss • When troubleshooting impaired service, it is critical to view the performance of the individual upstream channels.

  9. Impaired Service Troubleshooting

  10. Impaired Service Troubleshooting

  11. Impaired Service Troubleshooting

  12. Impaired Service Troubleshooting

  13. Impaired Service Troubleshooting • Obviously there is an issue with the channel at 19 MHz • Utilize this method to traverse the network and find the impairment causing this issue

  14. Summary • Partial Service • Tremendous Operational Advantage • Can go unnoticed • Impaired Service • Can be difficult to troubleshoot without the right tools • Many Impairments not detectable with • Packetloss • Throughput • Best Practice • Utilize tools that allow the simultaneous testing of bonded upstream channels at a PHY layer