1 / 14

AGI Inclinometer Georg Gassner, John McDougal, SLAC August, 2007

AGI Inclinometer Georg Gassner, John McDougal, SLAC August, 2007. Principle Accuracy Undulator Measurements. AGI Inclinometer. Principle Essentially a electronic spirit level:. AGI Inclinometer. Transient Response. Different Sensors. Y Axis: Range: ± 10 arc degree

bing
Download Presentation

AGI Inclinometer Georg Gassner, John McDougal, SLAC August, 2007

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. AGI Inclinometer Georg Gassner, John McDougal, SLACAugust, 2007 • Principle • Accuracy • Undulator Measurements 1

  2. AGI Inclinometer • Principle Essentially a electronic spirit level: 2

  3. AGI Inclinometer • Transient Response 3

  4. Different Sensors • Y Axis: • Range: ± 10 arc degree • Resolution: 1 microradian • Repeatability: 5 microradian • Linearity: 0.03 degree at ± 3 degree 0.17 degree at ± 6 degree • Scale factor: 34mV/degree ~3.5% • X Axis: • Range: ± 1 arc degree • Resolution: 0.1 microradian • Repeatability: 1 microradian • Linearity: 0.1 arcminute at ± 10 arc minutes 0.5 arcminute at ± 20 arc minutes • Scale factor: 7.2mV/arcminute/V ~2.5% 4

  5. Test on Sine Plate and Breithaupt plate (1) In order to verify the accuracy and linearity of the sensors we tested them on a sine plate and for the smaller range sensors on the Breithaupt stand 5

  6. Test on Sine Plate and Breithaupt plate (2) Y-Axis high 6

  7. Test on Sine Plate and Breithaupt plate (3) X-Axis low 7

  8. Test on Sine Plate and Breithaupt plate (2) Y-Axis high 8

  9. Undulator Measurements Purpose: Repeat the setup of the Undulator, regarding roll on the Dover Bench, the Kugler Bench, the CMM and in the Undulator Hall Measurements: on 3 spots at the flats at each end of one Undulator 9

  10. Undulator Measurements 10

  11. Undulator Measurements Protocol: 11

  12. Undulator Measurements Results: 12

  13. Undulator Measurements Check -> Index Error: 13

  14. End of Presentation 14

More Related