306460

Labnics aerosol generator, paired with a photometer for safety, offers a flow range of 1,500 to 65,000 CFM (42 to 1839.5 mu00b3/min), achieving concentrations of 10 u03bcg/L and 100 u03bcg/L at maximum flow. It efficiently handles PAO, DOP, and polydispersed particles using a heating-based occurrence method.<br>

bentleyfay
Download Presentation

306460

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. AEROSOL GENERATOR NASG-101

  2. AEROSOL GENERATOR NASG-101 Aerosol Generator NASG-101 is a safe aerosol generator coupled with a photometer. The aerosol particles produced have a wide diameter and provide challenge particles to measure the efficiency of filtration systems. Features oil circuit protection supply system and heat exchange function. The unit has flow range of 1,500 to 65,000 CFM (42 to 1839.5 m3/min), requires compressed inert gas and is easy to operate and stable. FEATURES ⇋ Safest aerosol generator coupled with photometer ⇋ Oil circuit protection system and heat exchange function ⇋ Flow range of 1,500 to 65,000 cubic feet per minute (42 to 1839.5 m3/min) ⇋ Produces particles with wide diameter as challenge particles ⇋ Ideal for measuring the efficiency of filtration systems, HEPA filters performance SPECIFICATIONS Available Flow Range Occurrence Concentration 1,500 to 65,000 CFM (42 to 1839.5 m3/min) 10 μg/L: flow 65,000 CFM (about 1839.5 m3/min); 100 μg/L: flow 65,000 CFM (about 1839.5 m3/min) PAO, DOP and polydispersion occur Heating occurs Nitrogen, Argon, Carbon dioxide or Helium (50 psi) AC 220 V to 240 V, 50/60 Hz 280 × 390 × 300 mm 14 Kg Particle Occurrence Method Compressed Gas Power Supply Dimension Weight APPLICATIONS Aerosol Generator is used to check the efficiency of filters as well as detect leakages in clean rooms, laminar flow table, biosafety cabinet, glove box, HEPA vacuum cleaner, HVAC system, HEPA filter, ULPA filter, negative pressure filter device and operating room.

  3. Labnics product catalog Generated on: 02/09/2024 Labnics Ltd. Unit 2D Station House, 1 Pembroke Broadway, Camberley, Surrey GU15 3XD United Kingdom Email: info@labnics.com | Website: www.labnics.com | Phone: +44 755 143 4216

More Related