An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Introduction What is the PCIMS? PCIMS :Process Control Information Management System Each plant as an individual process area shall consist of an integrated production control system and the main units of integrated production system consist of : UCB : Unit Control Building which is the central location for controlling , PCB: process control building RIB which will house all I/O’s and the controllers

  2. What is the DCS? DCS is Distribution Control System United project ,Yokogawa centum CS3000 which consist of two main parts : : Human Interface Station HIS -  it is operator station that is used to monitor and control the process . FCS : Field Control Station FCS is a stand alone unite capable of performing a full data acquisition control ,and all control function are executed there with all I/O’s analog & digital signal.

  3. What is the PESS ? PESS : Programmable electronic safety system ( Triconex ) which is used for emergency shutdown (ESD) function and other equipment tripping function . What is the PLC ? PLC is Programmable Logic Control The Modicon (PLC ) used for control of some package mechanical equipment like CWT & PSA .

  4. What is MMS ? MMS : Machine Monitoring system , (Bentlt Nevada ) Machine Motoring System , the Bently Nevada system is used to monitor the vibration of the shaft and the baring shaft temperature , and to send a signal as hard wire to the shut down system “ PESS” to trip the machine . Which is used in Comp package & critical big Pump..etc.

  5. What is RIB ? RIB is Remote Instrument Building The Remote Instrument Building RIB, which will house, the DCS controller as FCS ,HIS ,PESS / PLC controller and their cabinets and all other 3rd party equipment like,Vibration monitoring , Power supply distribution panel ,Fire and Gas panel and Uninterruptible power supplies (UPS ) .

  6. SWH

  7. Fiber optic cable RIB YNT Control room YNT V-Net cable 10 base 5 V-Net 10 Base 5 cable One jacket fiber optic cable consist of 6 cable which consist of 4 wire . So 12 pare wire inside one jacket FCS V-net 10 Base 2 cable FIO DCS OPC server PCMIS ,CISCO switch HIS To do down loading , Tag equalizing between the HIS,s,Trending , and viewing DCS logic HIS

  8. V-net cable connection V-net 2 V-net 1 FCS 02 FCS 01 HIS V-net communication card “VF 701”

  9. RIB One pair copper cable Serial communication link JB V-net cable 10 base 5 B/N FCS PLC FOPP PESS Optical converter FCU YNT F TA Copper multi core shielded cable TB Hard wire FIO Black box HIS FTA or I/O's cable twisted multi core ,as TEL cable V-net cable 10 base 2 coaxial cable FOPP Fiber optic cable YNT HIS HIS HIS Control Room V-net converter 10 base 5 to 10 base 10 YAA 24/03/03

  10. EOEG We have two RIB’s RIB 1 : FCS : 5 two for unit 21 , CAO package for the reactor “Advance Controller ” Computer Aided Operator , Unit 22/23 and Unit 29 PESS A : OMS AS three cabinets PESS B : COMPRESSOR as three cabinet BENTLY NEVADA “ MMS” as three cabinets Recycle Compressor , High pressure Nitrogen Comp , TAIL gas Comp , Carbonate Solution pump “ motor” , Stripping column bottoms pump , cycle water pump “ motor” PLC # 1 ,PSA as two cabinet RIB 2 : FCS : 3 for unit 25 ,26 ,27 PESS C : for EG suction , just one cabinet BENTLY NEVADA MMS , as only one cabinet for Reactor Feed Pump PLC # 2 ,CWT Cycle water treatment as two cabinet