University Building Official. Accessibility. Building Code.

loader
I am the owner, or an agent authorized to act on behalf of the owner, of the copyrighted work described.
capcha
Download Presentation

PowerPoint Slideshow about 'University Building Official' - awen


An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -
Presentation Transcript
building code
Building Code
  • A building code is a set of rules that specify the minimum acceptable level of safety for buildings. The main purpose of building codes are to protect public health, safety and general welfare as they relate to the construction and occupancy of buildings and structures.
  • A building built to the building code is the least safe building you can legally build.
accessibility
Accessibility
  • ADAAG
  • Authority to use ADAAG
    • Design Standards
    • Clarifications
  • Tolerances
  • Construction Details
accessiblity
Accessiblity
  • Authority
    • HECO Manual 7A.1
      • Americans with Disabilities Act Accessibility Guidelines (ADAAG), published July 23, 2004 and excluding the Architectural Barriers Act [ABA] Scoping Requirements.
      • Standards of VUSBC Chapter 11 and the IPC §405 do not apply to University facilities on Commonwealth property.
    • Facilities Design Guidelines GR.2.1
      • ADAAG is applicable to Commonwealth of Virginia new and renovated construction projects.
design standards for accessibility
Design Standards for Accessibility

HECO Manual 7A.2.1

  • Americans with Disabilities Act Accessibility Guidelines, July 23, 2004.
  • Available on-line
    • http://www.access-board.gov/ada-aba/index.htm
  • Clarifications for University Owned Buildings
clarifications
Clarifications
  • Accessible facilities must be provided at the completion of construction.
  • Adaptable facilities do not meet the requirements for accessibility unless demonstrated to the University Building Official to be readily implemented on demand.
  • All stairways shall be accessible to the disabled.
facilities design guidelines
Facilities Design Guidelines
  • Facilities shall be designed so that accessibility does not stand out or draw attention to it when other architectural alternatives are available.
    • Example, restroom lavatories shall be of uniform design with all lavatories meeting accessibility standards rather than just one unit meeting the standards.
    • This would not apply to toilet stalls, urinals or water closets.
facilities design guidelines cont
Facilities Design Guidelines Cont
  • Teaching and research laboratories shall have a minimum of five percent, but not less than one, work station for each type of facility (fume hood, bench, sink, etc.).
  • Compliance may be achieved using readily adjustable modular casework and equipment.
tolerances
Tolerances
  • ADAAG has some minimum and maximum dimensions for some of the elements. If a minimum and maximum is given, there is no tolerance for the element being outside of that range. (ADAAG Advisory 104.1.1)
  • If a minimum or maximum is given there is some tolerance, but the tolerance is not defined.
    • Element should be dimensioned to ensure the minimum or maximum is not exceeded. Don’t show the limit.
construction details
Construction Details
  • Chapter 3 - Building Blocks
    • 302 - Floor and ground surfaces
    • 303 - Changes in level
    • 304 - Turning space
    • 306 - Knee and Toe clearances
    • 307 - Protruding Objects
    • 308 - Reach Ranges
  • Chapter 4 - Accessible Routes
    • 403 - Walking surfaces
    • 404 - Doors
    • 405 - Ramps
construction details cont
Construction Details Cont.
  • Chapter 5 - General Site and Building Elements
    • 504 - Stairways
    • 505 - Handrails
  • Chapter 6 - Plumbing elements
    • 602 – Drinking Fountains
    • 603 – Toilet and Bathing Rooms
    • 604 – Water Closets and Toilet Compartments
    • 605 – Urinals
    • 606 – Lavatories and Sinks
    • 608 – Shower Compartments
construction details cont1
Construction Details Cont.
  • Chapter 6 - Plumbing elements
    • 609 – Grab Bars
    • 610 – Seats
  • Chapter 7 – Communication Elements and Features
    • 703 – Signs
  • Chapter 9 – Built-In Elements
    • 903 - Benches
302 floor and ground surfaces
302 - Floor and ground surfaces

Openings in floor or ground surfaces shall not allow passage of a sphere more than ½ inch diameter. Elongated openings shall be placed so that the long dimension is perpendicular to the dominant direction of travel.

303 changes in level
303 – Changes in level

Raised thresholds and changes in level at doorways shall be ½ inch maximum.

¼ vertical and ¼ at a slope of 1:2.

303 changes in level1
303 - Changes in Level

Raised thresholds and changes in level at doorways shall be ½ inch maximum.

¼ vertical and ¼ at a slope of 1:2.

protruding objects
Protruding Objects

Objects over a walking surface (VUSBC 1003.3.3) or into the circulation path (ADAAG 307.2).

308 reach ranges
308 – Reach ranges

Light switches, coat hooks, electrical outlets.

403 walking surfaces
403 - Walking Surfaces
  • Walking surface on accessible route
    • Cannot be steeper than 1:20
  • Ramp
    • Slope cannot exceed 1:12
    • Ramps require handrails if the ramp rise is greater than 6”
  • Grades steeper than 1:12 are not accessible
504 stairways
504 - Stairways
  • Tread and riser dimensions are no different that what is required in the VUSBC.
  • Open risers are not permitted.
505 handrails
505 - Handrails
  • Height of handrails is measured to the top of the gripping surface.
  • 34 inches minimum and 38 inches maximum above the walking surfaces, stair nosings and ramp surfaces.
  • Handrails shall be continuous from the top to the bottom of the stair flight.
505 handrail extensions
505 – Handrail extensions
  • Extend beyond and in the same direction of the stair flight or ramp run. 505.10
  • Ramp handrails shall extend horizontally above the landing for 12 inches minimum beyond the top and bottom of ramp runs. 505.10.1
handrail extensions
Handrail Extensions

The difference between the Building Code and ADAAG is that ADAAG says the extensions shall continue in the direction of the stair flight or ramp run.

handrail extensions1
Handrail Extensions

The 2009 International Building Code has changed the wording concerning handrail extensions for exit ramps and exit stairs to be in line with ADAAG.

stair handrail extensions
Stair Handrail extensions
  • At the top of a stair flight, handrails shall extend horizontally above the landing for 12 inches minimum beginning directly above the first riser nosing. 505.10.2
  • At the bottom of a stair flight, handrails shall extend at the slope of the stair flight for a horizontal distance at least equal to one tread width beyond the last riser nosing. 505.10.3
handrail extensions2
Handrail extensions
  • All handrail extensions shall return to a wall, guard, or the landing surface, or shall be continuous to the handrail of an adjacent stair flight or ramp run.
handrail extensions3
Handrail Extensions

The handrail extensions shall return to a wall, guard or the landing surface.

handrail extensions4
Handrail Extensions

The handrail extensions shall return to a wall, guard or the landing surface.

toilet and bathing rooms
Toilet and Bathing Rooms
  • Turning space is required.
  • Mirrors. Bottom of the reflective surface no more than 40 inches above the floor.
  • Coat hooks within reach ranges.
  • Shelves - 40 inches minimum and 48 inches maximum above the finish floor.
604 water closets2
604 – Water closets

Even at the rough-in stage issues can be identified.

604 3 2 overlap
604.3.2 – Overlap

Clearance at accessible water closets.

604 8 1 2 compartment doors
604.8.1.2 – Compartment Doors

Doors into accessible stalls shall be self closing. A door pull shall be placed on both sides of the door near the latch.

slide63
Doors into accessible stalls shall be self closing. A door pull shall be placed on both sides of the door near the latch.
605 urinals
605 – Urinals

If more than one urinal is installed, then at least one shall be accessible.

Height of the urinal shall be 17 inches maximum and the urinal shall be 13 ½ inches deep minimum.

606 lavatories and sinks
606 – Lavatories and sinks

606.3 - Lavatories and sinks shall be installed with the front of the higher of the rim or counter surface 34 inches maximum above the finish floor or ground.

606 lavatories and sinks1
606 – Lavatories and sinks

606.3 - Water supply and drain pipes under lavatories and sinks shall be insulated or otherwise configured to protect against contact.

608 shower compartments
608 – Shower compartments

Location of controls are key in shower compartments.

608 4 seats
608.4 – Seats

A seat is required in transfer type shower compartments.

608 shower compartments1
608 – Shower compartments

Location of controls are key in shower compartments.

609 grab bars
609 – Grab Bars

609.4 - Height of grab bars shall be between 33 inches minimum and 36 inches maximum above the floor. The grab bar is measured from the top of the gripping surface.

903 benches
903 - Benches

903.3 - Benches shall have seats that are 42 inches ling minimum and 20 inches deep minimum and 24 inches deep maximum.