1 / 21

The Solar Protection Relay by BCJ Controls | ComAp Intelipro

We offers installation, testing, commissioning, also we have a different protection relays. Call us: (02) 9534 8465. Visit our website for more info: http://bcjcontrols.com.au/

Download Presentation

The Solar Protection Relay by BCJ Controls | ComAp Intelipro

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Solar Protection Relay Subtitle

  2. Title and Content Layout with List • ABB REG630 Solar Protection Relay • Schneider Easergy– Micom p341 • Fanox SIL-G Protection Relay • Zero Export Controls – CEC2000 • Zero Export Controls – CEC3000 • Zero Export Devices – ZED 1, 2, 3, 4 | GNT Engineering • MFR300 – Multi-function Relay

  3. ABB REG630 Solar Protection Relay • The ABB REG630 Protection Relay is a zero export protection relay often used for solar PV embedded generation. • REG630 is a comprehensive generator management relay for protection, control, measurement and supervision of small and medium-sized power generators and generator-transformer units in utility and power distribution systems. • REG630 is a member of ABB’s Relion product family and a part of its 630 product series. The 630 series relays are characterized by functional scalability and flexible configurability. REG630 has been designed to be the main protection for synchronous generators, offering full protection during start-up and normal run for both the generator and the prime mover. REG630 is typically used in small and medium-sized diesel, hydroelectric, combined heat and power (CHP), and steam power plants.

  4. ABB REG630 Solar Protection Relay • The pre-defined configuration is intended for directly connected generator sets and can either be used as such or easily tailored to application-specific requirements with freely selectable functions. • REG630 can be used in either single or double-busbar applications with one or two breakers and numerous switching devices. It also supports a substantial number of both manually and motor-operated disconnectors and earthing switches. REG630 can therefore be used to control various types of switchgears. • REG630 fully supports the IEC 61850 standard for communication in substations and covers both vertical and horizontal communication, including GOOSE messaging with both binary and analog signals. REG630 also supports the DNP3 (TCP/IP) and IEC 60870-5-103 (serial) communication protocols. The supported communication protocols, including IEC 61850, offer seamless connectivity to various station automation and SCADA systems.

  5. Why ABB? • Flexible generator protection relay for synchronous generators • Differential protection, 3rd harmonic-based stator earth-fault protection, reverse power protection and extensive interconnection protection for distributed generation • Control of two circuit breakers and a total of eight disconnectors and earthing switches • Freely configurable functionality to meet application-specific requirements • Large, integrated or detached HMI

  6. ShneiderEasergyMiCom p341 • EasergyMiCOM P341 Interconnection protection relays can be customized to meet the specific needs of the intended application. They offer complete, cost-effective and highly reliable protection for operating machines. It also includes Dynamic Line Rating (DLR) protection to optimize transmission line capacity. Gains of 50% or more can be achieved, depending on the environmental conditions, enabling more Distributed Generation (DG) such as wind farms to be connected to the grid by taking into account the real time weather conditions to calculate the line rating compared to using the fixed summer/winter line ratings. DLR is a cost effective alternative to reinforcing overhead lines to increase capacity and there are also benefits to the wind farm owner in that higher revenues can be made with a higher line rating.

  7. ShneiderEasergyMiCom p341 • Extensive multi-functions and user-friendly logic • Multi-function relay range ensures flexible, reliable integration of protection, control, monitoring and measurements for a wide variety of system applications • Users can create complex protection schemes by using EasergyMiCOM’s powerful, user-friendly logic • Quality choice of industry standard protocols are available, facilitating integration into both new and existing network control systems • Flexible communications and cost-effective solutions • EasergyMiCOM relay family’s extensive protection functions meet the requirements for most interconnection and DLR protection applications and provide them with cost-effective solutions and offers flexible communications options • Latest communication protocols & Ethernet Redundancy (available now in P341)

  8. ShneiderEasergyMiCom p341 • Fully Equipped with the latest communications protocols (IEC61850 Ed1 & Ed2 available in the same device, selection by setting) • Maximum availability and reliability of Ethernet communications thanks to the implementation of PRP/HSR standard redundancy protocols with an instantaneous recovery time in case of network failure • Dual IP address allows the device to be connected to 2 independent communication networks (e.g, SCADA system network & Maintenance network) • Universal IRIG-B input (automatically detects modulated or unmodulated signal) • Major enhancement to Cybersecurity • Operational & Cyber Security, compliant to IEC 62351, helps protect installations with security based on embedded features such as Role Based Access Control (RBAC), Port Hardening, Security Logs and Access Traceability. The IED by default includes RBAC with different users defined and a Security Administrator.

  9. Fanox SIL-G • Protection functions available in SIL-G are the following: • 81R, 78, 81 U/O, 27P, 32/40, 59P, 59N, 25, 79, 50P, 50N/G, 67P, 67N, 46, 79, 50BF, 52, 49, 86,CLP, 49T, 74TCS, 37 and IRIG-B • Monitors differences in voltage magnitudes, phase angles, and frequencies to perform synchronism checks across the circuit breaker, can be coordinated with the auto-reclose function (up to five recloses) • Used with auxiliary power supply (110-230 Vac/ 90-300 Vdc and optionally 24-48 Vdc) • Two rear ports on the back for remote communication • Two communication protocols can be used simultaneously: MODBUS RTU and IEC 60870-5-103, IEC 61850, DNP 3.0 or IEC 60870-5-104

  10. Fanox SIL-G • Physical Features: • Metallic box with high electromagnetic compatibility level (EMC) and wide range of operating temperatures • Direct signalling/control on both of the circuit breakers(52 function) and both of the reclosers (79 function) • Reduced size makes the SIL-G relay easy to install and its light weight helps the customer to save costs in transport • 8 configurable inputs and 7 configurable outputs • 2 Oscillographic records, 20 fault reports and non-volatile RAM memory: stores 1.000 events with date/time even without power supply thanks to its internal RTC

  11. CEC2000 • Real time data interface • Configuration page has adjustable parameter settings to suit the requirements of any network • Zero Export to grid • Mechanically isolated • Six switching points • Export/Import Value Enabler • Anti-islanding • Ovevoltage and undervoltage protection • Under- and Over-frequency protection • Phase Failure Protection • Reverse Power Protection • ROCOF (rate of change of frequency) • Phase rotation detection • Error messages on faults • Email alerts • Self Calibrating • Real time clock • Internal battery backup • Internal watchdog • Multi layer password protection • USB and Lan ports • Used with all inverter brands • Weighs 200 grams • Easy installation • Din rail mounted • Internationally compatible

  12. CEC3000 • Real time data user interface • Configuration page with adjustable parameter settings to suit the requirements of any network • Zero Export to grid • Mechanically isolated • Six switching points • Export/Import value enabler: • Export – Allows controlled export to the grid as per the utility agreement (i.e. 100 kW approval with 20 kW allowable export) • Import – Satisfies need of a required minimum import of electricity to the site that some systems need

  13. CEC3000 • Monitors and logs data (i.e. KVA, Voltage, Current, Power factor, frequency etc.) • Real time data mobile viewing • Collect and store data on off site server for 10 years • Anti-islanding • Overvoltage and undervoltage protection • Under- and over-frequency protection • Phase Failure Protection • Reverse Power Protection • ROCOF (rate of change of frequency) • Phase rotation detection • Error messages on faults • Email alerts • Self Calibrating • Real time clock • Internal battery backup • Internal watchdog • Multi layer password protection • USB and lan ports • Used with all inverter brands • Weighs 200 grams • Easy installation • Din rail mounted • Internationally compatible

  14. ZED Relays • Inverter Control/Solar PV Production • The ZED devices communicate with the inverter via three (3) protocols, the choice of protocol is dependent on specific inverter compatibility. These protocols are 4 or 6 bit binary and RS 485 protocols. The 4 bit binary provides 16 levels of solar PV production between 0 and 100%. The 6 bit binary provides 64 levels of solar PV production between 0 and 100%. • RS 485 provides solar PV production in 1% increments.

  15. ZED Relays • 2.1 Compatible Inverters • There is a range of inverters that are compatible with the ZED family of devices can manage Solar PV production and deliver Zero Export.Inverters which can be controlled via 4 or 6 bit binary will require a management card supplied by the manufacturer of the inverter; these are often referred to as Power Control Modules, Power Management Units, Data Managers or controllers.Inverters that have RS 485/Modbus connection are managed via inverter specific protocols.Inverter performance and compatibility with the ZED family has been validated by GNT Engineering. • To date a number of inverters have been validated by GNT Engineering and are managing Zero Export solutions for 3 phase and single phase installations.

  16. ZED Relays • 2.2 Inverter List • 4 Bit Binary –  Fronius, SMA, Solar Edge, ABB ZeverSolar*6 Bit Binary – FroniusMODBUS RS485 – ABB, Schneider, Fronius,GoodWe, Delta*, Omnik*, Samil * ZeverSolar**Under Development

  17. MFR 300 • Other Solar Protection Relays are available here • The MFR 300 is a measuring transducer for monitoring single-phase and three-phase power systems. With both voltage and current inputs in order to allow this relay to measure an electrical power source. A digital processor carefully measures true RMS values, despite harmonics, transients, or disturbing pulses. Both the primary measured and the calculated values may be transmitted using the CAN open interface to a managerial control system. The MFR 300 looks at mains decoupling with various monitoring functions that include two time-dependent, freely configurable, undervoltage tracking functions for FRT and STI. The real, reactive, and apparent power and the power factor values are calculated using the primary measured values of voltage and current.

  18. MFR 300 Features: • • Three true RMS voltage inputs• Three true RMS current inputs• Class 0.5 accuracy for voltage, frequency, and current• Class 1 accuracy for real and reactive power or energy• Configurable trip/control set points• Configurable delay timers for individual alarms (0.02 to 99.99 s)• Four configurable relays (change-over)• Ready-for-operation relay• 2 kWh counters (max. 1012 kWh)• 2 kVARh counters (max. 1012 kvarh)• Programmable relay outputs to annunciate alarms• CANopen communication• Configurable via CAN bus• 24 VDC power supply

  19. MFR 300 Protections: • Over- and under-voltage• Over- and under-frequency• Voltage asymmetry• Overload• Rev/red power• Unbalanced load• Phase shift• Rate of change of frequency• Freely configurable time-dependent undervoltage monitoring for: FRT (fault ride-through) and STI (short-time interruption)

  20. BCJ Controls • BCJ Controls - commercial solar network protection unit - switchboard manufacturing including protection relay & anti-islanding and zero export devices. BCJ Controls is a solar technology company set up by ex-utility industrial sparkies. Between them they have a large amount of experience in electrical grid protection, as well as dealing with utilities on a day-to-day basis. • At BCJ Controls we produce Secondary Protection Switchboards with solar protection relays for Commercial Solar over 30kW grid connections. • We offers installation, testing, commissioning, also we have a different protection relays. Call us: (02) 9534 8465.

  21. BCJ Controls 2,17 Lorraine St, Peakhurst NSW 2210 http://bcjcontrols.com.au/