HPMP SUSTAINABLE APPROACH . UNIDO approach for the HPMP Main Meeting of OzonAction Networks from Mexico, Central and South America and the Caribbean. Trinidad & Tobago 4 to 7 Oct 2011. OUTLINE. PREFACE

loader
I am the owner, or an agent authorized to act on behalf of the owner, of the copyrighted work described.
capcha
Download Presentation

PowerPoint Slideshow about 'HPMP SUSTAINABLE APPROACH' - astro


An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -
Presentation Transcript
slide2

HPMP

SUSTAINABLE APPROACH

UNIDO approach for the HPMP

Main Meeting of OzonAction Networks from Mexico, Central and South America and the Caribbean.

Trinidad & Tobago 4 to 7 Oct 2011

outline
OUTLINE

PREFACE

1. ALTERNATIVES TO REPLACE THE COMMON HCFCs2. MAIN HCFCs USES IN LATINAMERICA AND CARIBBEAN3. HCFC-22: ACTUAL STATUS4. HCFC-22: HOW TO REDUCE CONSUMPTION5. RECLAIM: ALTERNATIVE TO REDUCE CONSUMPTION6. HCFC-141b: ACTUAL STATUS7. HCFC-141b: ALTERNATIVES TO REDUCE CONSUMPTIONCONCLUSIONS

preface
PREFACE

REFRIGERANT IS NOT TO BE BLAMED.

OBJECTIVE: Eliminate the use of CFCs and HCFCs, could also mean using the refrigerant properly to reduce their consumption.

Refrigerant is very expensive and we use it once and throw it away or plan to destroy, something like the consumer society applied to the refrigerants

alternatives to replace the hcfcs
ALTERNATIVES TO REPLACE THE HCFCs
  • Replacement refrigerants (Drop-in with alternative refrigerant): eg. HFC, HC
  • Renewal of existing equipment (Retrofitting)
  • New refrigerants:HFOs and HFCs (R407a, R410a, R422a, R422d, R417A, R32, HFO1234yf ...)Natural (R290, R290/R600, R717, R744)None of these alternatives is included in this presentation

Where possible UNIDO promotes natural refrigerants, while making the transition must take into account the concept of proper management

2 main hcfcs uses in the latinamerica and caribbean
2. MAIN HCFCs USES IN THE LATINAMERICA AND CARIBBEAN

HCFC-22

  • ODP (ODP) = 0.055 (CFC-11 = 1) GWP (GWP) = 1810 (CO2 = 1)Main applications:Air conditioning, chillers (7 to 700kW), commercial refrigeration, condensing units, fisheries, boats in general, transport and others.

HCFC-141b

  • ODP (PAO)= 0.11 (CFC-11=1) GWP (PCG)=725 (CO2=1)
  • Main applications:
    • Blowing agent used for de polyuretane foam.
    • Solvent used for flushing refrigeration systems during service
3 hcfc 22 actual status
3. HCFC-22: ACTUAL STATUS
  • No awareness and good practice.
  • The concept was created and is generally used for R-12
  • Because of its low ODP were not assimilated into National plans
  • It was promoted as an alternative to R-12 without regard to their suitability
  • Vented for repairs and maintenance
  • It is still available at low prices, the market was flooded due to the perverse incentive.
4 hcfc 22 alternatives to reduce consumption
4.HCFC-22: ALTERNATIVES TO REDUCE CONSUMPTION
  • Economic incentive (saving = income)
  • Reuse the refrigerant
  • Recycling: in situ / sent to the existing network
  • Promotion of virgin refrigerant savings through recycling and reuse with their economic advantage
  • Courses focused on proper handling of refrigerant in large consumer savings, commercial refrigeration, large installers, hotels, ships, chiller, etc ...
  • Reclaim interesting concept…
4 hcfc 22 how to reduce consumption
4.HCFC-22: HOW TO REDUCE CONSUMPTION

CONCRETE STEPS (I) - HEAVY-Service site

  • OBJECTIVE: NO VENTING THE REFRIGERANT, NO OPENING THE VALVE
  • Recover all the refrigerant transfer cylinders (liquid transfer pump)
  • Recover the remaining refrigerant (machine recovered)
  • Recycle the refrigerant while doing the service (filter kit)
  • Apply good refrigeration practices (using the adecuate tools)
  • Recharging the refrigerant the shortfall. This not mixture!

RESULT: the refrigerant in good condition can be reused reducing consummption

4 hcfc 22 alternatives to reduce consumption1
4.HCFC-22: ALTERNATIVES TO REDUCE CONSUMPTION

Tools for high volume installations

Liquid transfer pump for refrigerants

Cost ca. US$ 4,500

Set to recycle and separate oil from the refrigerant

Cost ca. US$ 300

Recovery machine for refrigerant

Cost ca. US$ 500

4 hcfc 22 alternatives to reduce consumption2
4.HCFC-22: ALTERNATIVES TO REDUCE CONSUMPTION

CONCRETE STEPS (II) – General ServiceAplications

  • Good practices training focused in the need and use of large consumers. Review actual consumption and find how much can be saved changing the concept?
  • Recycling services in place if feasible (cylinders and equipment for recovery and recycling)
  • Take advantage of the R&R network if you can not do directly
  • Reclaim: economically efficient and viable solution, create the infrastructure for reclaim depending on conditions and needs
4 hcfc 22 alternativas para reducir consumo
4.HCFC-22: ALTERNATIVAS PARA REDUCIR CONSUMO

RESULTS OBTENIED IN DIFFERENT CASES

  • Pilot project was implemented with this concept in Margarita Island in Venezuela, some results:
    • Year 2009 R-22: 100kg recovered and reused; R-134 rd: 475kg recovered, reused 350kg; even with R-404: 49 kg recovered, reused 37kg
    • Application: Recycling in situ using appropriate tools (cylinders and equipment recovery and recycling)
  • Without using the recovery and recycling network in Venezuela in 2010 was recycled about 70 tons of R-22 in different service shops, not big consumers
4 hcfc 22 alternativas para reducir consumo1
4.HCFC-22: ALTERNATIVAS PARA REDUCIR CONSUMO

COSTS & POTENTIAL SAVINGS

A kilo of virgin HCFC-22 costs approx. $ 8  A home air-conditioned has ca. 1 kilo and a type 'split ducted' 3.25kg on average in both cases and can be recycled and reused. Cost of refrigerant = 0 saving 100%  A chiller can have 100kg of R-22 refrigerant value of new $ 800, whether to replace the 20% paid $ 160.  Reclaim the refrigerant has a cost, assuming that the service is paid $ 4 per kilo, the net savings is 50%. (covers transportation costs). If just service is provided.

Reclaimer buys at US$ 2/kg and sells reclaimed at ca. US$ 6/kg, virgin cost US$ 10

5 reclaim alternative to reduce consumption
5. RECLAIM: ALTERNATIVE TO REDUCE CONSUMPTION

RECLAIM a good concept to save refrigerant

Reclaim is the chemical process by which impurities are removedAHRI Certification Air Conditioning, Heating and Refrigeration InstituteAHRI 700 - 2006 revised 2008Establish test procedures for determining the quality of new or reclaimed refrigerants for use in refrigeration and air conditioning whether used or new.

5 reclaim alternative to reduce consumption2
5. RECLAIM: ALTERNATIVE TO REDUCE CONSUMPTION

CERTIFICACION AHRI: All reclaimed refrigerant must undergo tests:

Gas mixing must be incinerated.

1. Acidity: Acid attacks the seals of the systems. Deteriorate inside the storage cylinders. 2. Humidity: Refrigerant high moisture can cause clogging of lines due to the formation of ice affects the heat transfer. 3. Waste high boiling point (oil): High content of non condensable affects the compressibility of the refrigerant, causing high pressures in the system.

5 reclaim alternative to reduce consumption3
5. RECLAIM: ALTERNATIVE TO REDUCE CONSUMPTION

4. Chlorine: Coolant high chlorine level will produce a system with acidic conditions due to the production of HCl. 5. Condensable gases (air): It creates inefficiency in the system. Oil causes formation of additional substances in the system.

6. Purity: mixture of refrigerants not produce the same conditions as pure gas. Gas chromatograph.

5 reclaim alternative to reduce consumption4
5. RECLAIM: ALTERNATIVE TO REDUCE CONSUMPTION

Reclaiming machines LV

 Meets all EPA certification requirements Manufactured to customer’s specifications with options to handle different refrigerants including R12, R22, R407c, R410a… and many more 1 HP Hermetic compressor Reclaim capacity: 1.4 kgs. Liquid per minute. Vapour slightly less. On board storage capacity: 14 Kgs.

5 reclaim alternative to reduce consumption5
5. RECLAIM: ALTERNATIVE TO REDUCE CONSUMPTION

Reclaiming machines JV

  • Meets all EPA certification requirements
  • Manufactured to customer’s specifications with options to handle different refrigerants including R12, R22, R407c, R410a… and many more
  • 2 HP Hermetic compressor
  • Reclaim capacity: 2.3 kgs. Liquid per minute. Vapour slightly less.
  • On board storage capacity: 40 Kgs.
5 reclaim alternative to reduce consumption6
5. RECLAIM: ALTERNATIVE TO REDUCE CONSUMPTION

Reclaiming machines BV

  • Meets all EPA certification requirements
  • Manufactured to customer’s specifications with options to handle different refrigerants including R12, R22, R407c, R410a… and many more
  • 2 HP Hermetic compressor
  • Reclaim capacity: 2.3 kgs. Liquid per minute. Vapour slightly less.
  • On board storage capacity: 136 Kgs.
5 reclaim alternative to reduce consumption7
5. RECLAIM: ALTERNATIVE TO REDUCE CONSUMPTION

Reclaiming machines HSR

  • New industrial size recovery unit.
  • Pumps liquid and vapour. Recovers R410a, R407c, R404a and other alternates.
  • 3 HP Rotary compressor
  • Reclaim capacity: 3.6 kgs. Liquid per minute. Vapour slightly less.
  • Oversized condenser
  • Ideal for production line or in plant use.
6 hcfc 141b situaci n actual
6. HCFC-141b: SITUACIÓN ACTUAL
  • Used as a solvent for cleaning equipmentVented 100%, used once, which generates costs and consumption"We cleaning the system and get dirtythe environment “
6 hcfc 141b alternatives to reduce consumption

Flushing unit

6. HCFC-141b: ALTERNATIVES TO REDUCE CONSUMPTION
  • Equipment for cleaning solvent or circuits using HCFC-141b as a cleaning agent.
  • Efficiency> 96%.
  • Cost approx. US$ 300
  • It has solvent pump with 100% yieldIt can be manufactured locally pump
  • Reuse of R-141b to 40-50 times
  • Other alternatives, solvents with low boiling
7 conclusiones
7. CONCLUSIONES
  • Reducing emissions of ODS
  • The reduced consumption of pure refrigerant is achieved not only with alternatives, if we already have refrigerant saquémosle the most
  • The development of a refrigerant involved investments of millions and we sold after one use that can be recycled
  • Cost savings, environmental seal service
  • With proper use of refrigerant consumption is reduced
  • The service includes recycling is more expensive, but cheaper than that required to add coolant. Good for the installer, user and environment.
  • Win - win.
thanks for your attention
Thanks for your attention

Rodrigo Serpa

Industrial Development Officer

Montreal Protocol Branch

UNIDO

R.Serpa@unido.org

www.unido.org

Tel: +43 1 26026 3320

25

25