1 / 15

FP420 Cryogenics requirements

FP420 Cryogenics requirements. T. Colombet (At-Mcs). 11th of December 2006. Principle :. The FP420 connection cryostat :. ATM module. Beam tubes. Line X vacuum vessel. Connection Module. T. Colombet (At-Mcs). Modifications involving cryogenic aspects:.

ardelle
Download Presentation

FP420 Cryogenics requirements

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. FP420 Cryogenics requirements T. Colombet (At-Mcs) 11th of December 2006

  2. Principle : The FP420 connection cryostat : ATM module Beam tubes Line X vacuum vessel Connection Module T. Colombet (At-Mcs)

  3. Modifications involving cryogenic aspects: Standard connection cryostat extremity FP420 connection cryostat extremity 1.9 K 70 K Room temperature Line X

  4. Principle : Modifications involving cryogenic aspects: • Line X with a special vessel. • Warm/cold transition. • No standard cold mass with bottom tray/MLI... • No thermal exchange between a “central shuffling module” and line X. • New supporting systems. • More electrical connections

  5. General requirements: • Cryogenics : • single smooth circular tube of 50 mm inner diameter. • total free cross-section of at least 60 cm2 . • Heat loads must fulfill general LHC specification. • Lambda front and maximum temperature values must fulfill the LHC requirements. T. Colombet (At-Mcs) 09 Octobre 2006

  6. Heat loads DS heat load : T. Colombet (At-Mcs) 09 Octobre 2006

  7. Static heat loads

  8. Vacuum vessel Room temperature x Thermal screen Sub cooled at 10K or 80K Line X Helium gas/liquid 1.9 k Line y Liquid helium 1.9 K Line X – heat exchanger line • ≈ 14 meters longs • must be kept under 2 K Do we actively cool down the screen at 80K (line E) or 10K (line C’) ?

  9. Line X – heat exchanger line vessel Heat exchange between 300K and 80/10 K : screen Heat flux = 1.5 W/m2 length = 9 m surface = 3.1 m2 x Heat = 4.65 W y Heat exchange between 80/10 K and1.9K : Heat flux = 0.05 W/m2 length = 9 m surface = 1.6 m2 Heat = 0.08 W To be studied : _ Heat capacity of line X _ Heat capacity of line C’

  10. Warm-Cold transition New and important heat exchange between 300K and 4.2 K. Studies of impacts have to be done.

  11. Connection module cryostat Vacuum vessel Room temperature x Thermal screen + Line E Sub cooled at 80K gas helium Line C’ Liquid helium 4.1 k Line M Liquid helium 1.9 K Line N Liquid helium 1.9 K

  12. Lambda Front _ Lambda front will propagate from the adjacent cryomagnet. Studies have to be done.

  13. Supporting systems Link between 300K and 1.9K : Two “standard” dipole feet Spacers Warm/cold transition Spacers

  14. Superconducting bus bars Standard Connection cryostat interconnection interconnection ATM cryomagnet Connection module ATM Electrical connection Fixed point Lyra or compensation system Electrical connection Quench propagation ? Contraction ? Heat load ?

  15. Dynamics heat loads Studies have to be done.