1 / 12

Energy Resolution and Mean are obtained using the Weighted average Method.

ScECAL Fermilab Beam Test analysis ScECAL Group Meeting Kyungpook National University, Daegu, Republic of Korea, August 3 rd , 2011 Adil Khan, Satoru Uozumi, DongHee Kim. 1. ScECAL Linearity & Energy Resolutionc.

annick
Download Presentation

Energy Resolution and Mean are obtained using the Weighted average Method.

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. ScECAL Fermilab Beam Test analysisScECAL Group MeetingKyungpook National University, Daegu, Republic of Korea,August 3rd , 2011Adil Khan, Satoru Uozumi, DongHee Kim

  2. 1. ScECAL Linearity & Energy Resolutionc • For all the points 1,2,4,8,12, 15, 20,30,32 using the Mip constant values extracted at low Temperature. • Temperature Correction also applied • Energy Resolution and Mean are obtained using • the Weighted average Method. Energy resolutionare obtained after fitting :

  3. Devaition from Linearity Deviation from the Linear behavior of the measured deposited energy as a function of the beam momentum in case of using Mip constant corrected with low temperature and also Temperature correction

  4. 2. ScECAL Linearity & Energy Resolution • For all the points 1,2,4,8,12, 15, 20,30,32 using the Mip constant values extracted at High Temperature. • Temperature Correction also applied • Energy Resolution and Mean are obtained using the • Weighted average Method. Energy resolutionare obtained after fitting :

  5. Deviation from Linearity Deviation from the Linear behavior of the measured deposited energy as a function of the beam momentum in case of using Mip constant corrected with High temperature and also Temperature correction

  6. SCEAL deposited energy in Mips Vs. number of Events 32GeV 30GeV 15GeV 20GeV

  7. 1 GeV 2 GeV 4 GeV 8 GeV 12 GeV

  8. BACK UP

  9. Plan • Check for event Selection • study systematic uncertainty

  10. Devaition from Linearity Deviation from the Linear behavior of the measured deposited energy as a function of the beam momentum in case of using Mip constant corrected with low temperature and also Temperature correction

  11. Devaition from Linearity Deviation from the Linear behavior of the measured deposited energy as a function of the beam momentum in case of using Mip constant corrected with High temperature and also Temperature correction

More Related