1 / 13

Large Diagnostic Neutral Beam Injectors of Budker Institute of Nuclear Physics

Large Diagnostic Neutral Beam Injectors of Budker Institute of Nuclear Physics. V.Davydenko. Budker Institute of Nuclear Physics, 630090, Novosibirsk , Russia. Outline. RUDI DNBI W-7X DNBI H - sources at BINP. Diagnostic neutral beam injector RUDI. RUDI at TCV. RUDI ion source.

amalie
Download Presentation

Large Diagnostic Neutral Beam Injectors of Budker Institute of Nuclear Physics

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Large Diagnostic Neutral Beam Injectors of Budker Institute of Nuclear Physics V.Davydenko Budker Institute of Nuclear Physics, 630090, Novosibirsk, Russia

  2. Outline • RUDI DNBI • W-7X DNBI • H- sources at BINP

  3. Diagnostic neutral beam injector RUDI

  4. RUDI atTCV

  5. RUDI ion source Eb= 50–53 keV Ib= 2–2.8 A T= 2–10 s δα≈0.5° F= 4 m 1- soft metal case, 2 - gas feeding tube, 3 - inner magnetic shield, 4 - trigger, 5 - ceramic wall, 6 - RF coil, 7 - pull stud (insulator), 8 - ceramic spacers, 9 – beam duct, 10 - water inlet manifold, 11 - grounded grid, 12 - accelerating grid, 13 - extracting grid, 14 - plasma grid, 15 - magnets, 16 - co-axial feedthrough

  6. Geometrical beam focusing

  7. RUDI grid set

  8. CVI 5290 Ǻ line emission intensity at TEXTOR

  9. DNBI arrangement atW-7X DNBI

  10. DNBI W-7X ion source Eb= 60 keV Ib= 10–12 A T=10–60 s F= 6 m

  11. Electrode of DNBI W-7X ion optical system water channels

  12. H- sources at BINP • 10 A, 25 keV, 0.01 s pulse H- ion source • 15-50 mA, 30 keV DC H- ion sources The beams can be accelerated up to 150-200 keV

  13. Summary BINP is ready to participate in ITER DNBI development

More Related