Planetary Environment Atmospheric Research Laboratory, PEARL University of Michigan Ann Arbor, MI
Current Instruments • Scanning Lidar • Meteorology sensors, T, P, humidity, wind • Particle concentration (MiniPCS) • Eddy correlation instruments • Microwave radiometer, KU-band
Lidar Characteristics • ParameterValue/Type • Laser SourceNd:YAG • Wavelength 1570 nm • Pulse Length 10.9 ns • Laser Beam Divergence 12 mrad • Pulse Energy 70 mJ • Telescope 10" Schmidt-Cassegrain • Telescope Divergence10 mrad • System Dimensions44" L x 40" H x 30" W • Primary Power110 VAC, 10 A
RPV Characteristics • Stable and robust • Short take off/landing & fast rate-of-climb: supercharged, 4-cycle engine • Simple autopilot • GPS system for out-of-sight flights • APRS system for viewing the airplane position in real time on a laptop computer