1 / 53

WEL COME

WEL COME. FIELD DETERMINATION, PRESERVATION TECHNIQUES. LABORATORY PREPARATION FOR SAMPLING. SAMPLERS SAMPLE CONTAINERS REAGENT SOLUTIONS INSTRUMENTS FIELD KIT GLASSWARES. CHECK LIST FOR COLLECTION OF SAMPLE. SAMPLING TOUR PROGRAMME AREA MAP ICE BOX FILLED WITH ICE DO SAMPLER

Download Presentation

WEL COME

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. WEL COME

  2. FIELD DETERMINATION, PRESERVATION TECHNIQUES

  3. LABORATORY PREPARATION FOR SAMPLING SAMPLERS SAMPLE CONTAINERS REAGENT SOLUTIONS INSTRUMENTS FIELD KIT GLASSWARES

  4. CHECK LIST FOR COLLECTION OF SAMPLE SAMPLING TOUR PROGRAMME AREA MAP ICE BOX FILLED WITH ICE DO SAMPLER BOD BOTTLE SAMPLE CONTAINERS SAMPLE PRESERVATIVES

  5. CHECK LIST FOR COLLECTION OF SAMPLE TISSUE PAPERS SAMPLE ID FORMS FIELD NOTE BOOK SOAP AND TOWEL DRINKING WATER TRANSPORT ARRANGEMENT SAMPLING SITE LOCATION MAP WEIGHTED BOTTLE SAMPLER

  6. CHECK LIST FOR COLLECTION OF SAMPLE ROPE SAMPLE CONTAINERS DO FIXING AND TITRATION CHEMICALS & GLASSWARES THERMOMETER FIELD KIT,AS REQUIRED LABELS FOR SAMPLE CONTAINERS PEN,PENCIL,MARKER,MATCH BOX,TORCH,KNIFE,GLOVES & EYE PROTECTION

  7. Sample Collection RECOMMENDED SAMPLE COLLECTION DEVICES AND TYPES

  8. Sample Collection SAMPLE COLLECTION DEVICE AND TYPE • D.O.SAMPLER WITH 300 ml BOD BOTTLE • ( TO AVOID AIRATION) • 2)DEPTH INTEGRATING SAMPLER= D-74 • ( DEPTH UPTO 4.72 m) • 3)DEPTH INTEGRATING SAMPLER= P-74 • ( DEPTH MORE THAN 4.72 m)

  9. DO SAMPLER

  10. DO SAMPLER 20-30 CM BELOW THE SURFACE

  11. SAMPLING FOR D.O. WATER LEVEL 20-30 CM BELOW THE SURFACE

  12. D-74 SAMPLER FOR DEPTH UP TO 4.72 m

  13. DEPTH INTEGRATING SAMPLER D-74 SALIENT FEATURES- CAST IRON STREAM – LINE BODY BOTTOM HINGED HEAD BOTTEL FITS IN TO THE CHAMBER TAIL VANES 4.8 mm NOZZEL NOZZELS-6.4mm,4.8mm AND 3.2mm AIR OUTLET VELOCITY – 2.4 m/s DEPTH – 4.72 m

  14. P-61 SAMPLER FOR DEPTH MORE THAN 4.72 m

  15. POINT INTEGRATING SAMPLER P-61 SALIENT FEATURES BRONZE CASTING – STREA LINED BOTTOM HINGED HEAD TAIL VANES 4.8mm NOZZEL PRESSURE EQUILISING CHAMBER ROTARY SOLENOID ACTIVATED VALVE 24 VOLTS CURRENT COLLECTING SAMPLES AT SELECTED POINT USED AS DEPTH INTEGRATING SAMPLERIN DEEP STREAM(DEPTH MORE THAN 4.72m)

  16. USDH-48 SAMPLER USED WHERE :V x D < 1

  17. USDH-48 SAMPLER SALIENT FEATURES LIGHT WEIGHT,SMALL & EASY TO OPERATE USED WHERE VELOCITY x DEPTH < 1 AIR OUTLET ALLUMINIUM CASTING WEIGHT 2 KG NOZZEL –6.30mm,4.80mm,3.15mm COLLECTING SAMPLES WITHIN 9 cm OF STREAM BED REQUIRED CABLE AND FISHWEIGHT

  18. SELECTION OF ANALYTICAL PARAMETERS CONSIDERING WATER YEAR FROM JUNE TO MAY PARAMETERS TESTED IN LAB (AS PER TYPE OF LOCATION) BASELINE – Ist-30– Balance –20 TREND - Ist-30– Balance –20 TREND/FLUX -Ist-30– Balance –20 RESERVIOR/DAM -Ist-32– Balance –22

  19. CLIPS

  20. SAMPLING FOR DO

  21. SAMPLING FOR BACTERIOLOGICAL SAMPLE

  22. WATER TESTING KIT ( FIELD KIT)

  23. FIELD TEST MEASUREMENT OF FIELD PARAMETERS COLOUR,ODOUR,TEMPARATURE,EC,pH,& DO ARE FIELD PARAMETERS AND ARE TO BE ANALYSED AS SOON AS SAMPLE IS COLLECTED MEASUREMENTS OF THESE PARAMETERS CAN BE MADE BY USING FIELD KITS.THIS IS BEST OPTION ANOTHER OPTION- NEARBY LEVEL-1 LAB D.O.SAMPLE MUST BE FIXED IMMIDIETLY AFTER COLLECTION OF SAMPLE TEMPARATURE MUST BE MEASURED AT THE SITE ONLY

  24. FIELD TEST FILLING AN ID FORM

  25. “SAMPLE ID FORM”

  26. FIELD TEST • COLOUR CODES • LIGHT BROWN • BROWN • 3) DARK BROWN • 4) LIGHT GREEN • 5) GREEN • 6) DARK GREEN • 7) CLEAR • 8) OTHER SPECIFY

  27. FIELD TEST ODOUR CODE 1) ODOUR FREE 2) ROTTEN EGGS 3) BURNT SUGAR 4) SOAPY 5) FISHY 6) SEPTIC 7) AROMATIC 8) CHLORINIOUS 9) ALCOHOLIC 10)UNPLEASENT

  28. FIELD TEST TEMPARATURE IN DEGREE CELCIOUS BY USING THERMOMETER OR TESTING KIT

  29. FIELD TEST pH INDICATES CONCENTRATION OF H AND OH IONS INDICATES ACIDIC OR ALKALINE NATURE OF WATER WATER IS ACIDIC WHEN pH < 7 WATER IS ALKALINE WHEN pH > 7 THE pH of DISTILLED WATER IS 7

  30. FIELD TEST MEASUREMENT OF pH • LITMUS PAPER- • ACIDIC –BLUELITMUS PAPER TURNS IN TO RED • ALKALINE – REDLITMUS PAPER TURNS IN TO BLUE • NUTRAL – NO CHANGE IN ANY PAPER • BY USING pH PAPER HAVING VALUES OF VARIOUS RANGES 4-11 (UNIVERSAL),1-14,1-10 etc.

  31. FIELD TEST MEASUREMENT OF pH pH COMARATOR -DISC OF pH 10 ml TEST TUBE UNIVERSEL INDICATOR

  32. FIELD TEST MEASUREMENT OF pH • ELECTRICAL pH METER OR PENTYPE • REQUIRED STOCK SOLUTION • BUFFER SOLUTION OF 4,7, & 9.2 • CALIBRATION OF INSTRUMENT BY USING BUFFER SOLUTION TO TAKE OBSERVATION

  33. FIELD TEST DISSOLVED OXYGEN • GLASS WARES-D.O.BOTTLE,PIPPETES,BURRETS & CONICAL FLASK etc. • CHEMICALS( BUFFER SOLUTION) • 1) MANGNESE SULPHATE, • 2)ALKALI IODIDE AZIDE REAGENT • 3) STARCH SOLUTION • 4) SODIUM THIOSULPHATE • 5) CONC.H2SO4

  34. FIELD TEST ELECTRICAL CONDUCTIVITY EC AT FIELD – EC METER -CALIBRATION OF INSTRUMENT -RINSE CONDUCTIVITY CELL –0.01 M KCL MEASURE RESISTANCE, TEMPARATURE ADUST METER TO 1412 Micro mhos./cm COMPUTE THE CELL CONSTANT Kc RINSE CELL IN SAMPLE CALCULATE EC

  35. FIELD DETERMINATION

  36. FIELD DETERMINATION MEASUREMENT OF D.O.

  37. MEASUREMENT OF D.O. RESULT OF D.O. IS 4.74

  38. SAMPLE LABELLING SAMPLE CODE NUMBER DATE AND TIME OF SAMPLING SOURCE AND TYPE OF SAMPLE PRETREATMENT OR PRESERVATION ANY SPECIAL NOTE FOR ANALYST SAMPLERS NAME ,etc.

  39. HYDROLOGY PROJECT(SW) MAHARASHTRA WATER QUALITY LAB LEVEL-II @ NASHIK Name of Location: ID No. River: Tal: Dist: Date of sampling: Sampling Time : Sample collected by: Sample received by: Sr.No. in Sample entry register: SAMPLE LABEL

  40. SAMPLE PRESERVATION AND TRANSPORTATION

  41. Water Quality Parameters Recommended Maximum Storage Times.

  42. Parameter Group Parameter Recommended Required General Temperature Immediate Immediate Suspended Solid 7 days 7 days Conductivity 28 days 28 days pH Immediate Immediate Dissolved Oxygen 8 hours 8 hours Total Dissolved Solids 7 days 7 days Nutrients Ammoniacal Nitrogen 7 days 28 days Total Oxidized Nitrogen --- 28 days Total Phosphorus --- --- SAMPLE PRESERVATION AND TRANSPORTATION Water Quality Parameters Recommended Maximum Storage Times.

  43. Organic Matter COD 7 days 28 days BOD 6 hours 48 hours Major Ions Sodium 6 months 6 months Potassium 6 months 6 months Calcium 6 months 6 months Magnesium 6 months 6 months Carbonates and Bicarbonates 24 hours 14 days Chloride 28 days 28 days Sulphate 28 days 28 days Water Quality Parameters Recommended Maximum Storage Times.

  44. Other Inorganic Silica 28 days 28 days Fluoride 28 days 28 days Boron 28 days 6 months Metals Cadmium3 6 months 6 months Mercury3 28 days 28 days Zinc3 6 months 6 months Organics Pesticide (Indicator 7 days 7 days Synthetic Detergents --- --- Organic Solvents --- --- Phenols3 --- 28 days Micro bio Total Coliforms 8 hours 24 hours Biological Chlorophyll ’a’ 30 days ----- Water Quality Parameters Recommended Maximum Storage Times.

  45. SAMPLE TRANSPORTATION

  46. SAMPLE TRANSPORTATION WITHIN 24 HOURS TO CONCERN LABORATORY USE ICE BOX ( 40 C DARK) DURING TRANSPORTATION FOR MPN SAMPLES

  47. ICE BOX ( 40 C DARK)

  48. ANALYSIS OF SAMPLES IN THE LABORATORY

  49. MPN TEST

  50. CHEMICAL ANALYSIS

More Related