1 / 37

SIMATIC PCS 7 TeleControl

SIMATIC PCS 7 TeleControl. Plant Automation and telecontrol in one system. WAN. LAN. RTU. RTU. RTU. RTU. RTU. What is SIMATIC PCS 7 TeleControl and What’s the use of it?. Intro. Components. OS. OS. OS. OS. OS. Configurations. +. Engineering. TC in Oil & Gas. TC in Water.

Download Presentation

SIMATIC PCS 7 TeleControl

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. SIMATIC PCS 7TeleControl • Plant Automation • and telecontrol • in one system

  2. WAN LAN RTU RTU RTU RTU RTU What is SIMATIC PCS 7 TeleControl and What’s the use of it? Intro Components OS OS OS OS OS Configurations + Engineering TC in Oil & Gas TC in Water Summary AS AS AS Process Control System SIMATIC PCS 7 TeleControl SIMATIC PCS 7 Standard OS = Operator Station, AS = Automation System, LAN = Local Area Network, RTU = Remote Terminal Unit, WAN = Wide Area Network Plant Automation and TeleControl integrated in one system !

  3. What is SIMATIC PCS 7 TeleControl and What’s the use of it? Intro • SIMATIC PCS 7 TeleControl • Supported protocols: • SINAUT ST7, Modbus (serial / TCP/IP) • Protocol standards IEC 870, DNP V3 (in preparation) • Correct event time-stamp for all alarms stc. by the RTU (Remote Terminal Unit) • Ability to handle time-delayed transmission • Time-synchronization of RTUs • Automatic monitoring of all outstations(alarming in case of failure of the station or the connection) • Programming / Parameterization of the SIMATIC S7-RTUs(independent of used transmitting medium of the telecontrol connection) • Library with TeleControl function blocks incl. Symbols and Faceplates for Operator Station with SIMATIC PCS 7 „Look&Feel“ Components Configurations Engineering TC in Oil & Gas TC in Water Summary

  4. WAN WAN SIMATIC PCS 7 TeleControlComponents - Overview SIMATIC PCS 7 OS Clients Intro • Operator Stations exactly adapted acc. to quantity structure of the plant • Powerful Engineering System • Optimal Remote Terminal Units (RTUs) acc. to the particular application and the specific environment conditions • Flexible connection of RTUs to the existing communication infrastructure Eng. Station/ Single user OS Components Configurations Engineering TeleControlOS-Server (redundant) TC in Oil & Gas TC in Water ConverterTCP/IP  serialor centralSINAUT TIM Summary TCP/IPWAN Router Modem TeleControl RTUs withTCP/IP communication TeleControl RTUs withserial communication RTUs Optimized components, tailored to the particular Application

  5. SIMATIC PCS 7 TeleControlComponents for Remote Terminal Units (RTUs) Intro • Small size RTU: typically up to ca. 30 I/O • integrated interface for Modbus, IEC*) • extended temperature range of -40°C to +70°C • lower power consumption (< 5W) • optimized for outdoor applications • Medium size RTU: typically up to ca. 100 I/O • S7-300 with SINAUT TIM, IEC lib. *) or Modbus CP • Safety as an option with S7-300F • ultimate flexible configurations • Big size RTU: typically up to ca. 500 I/O • S7-400 with SINAUT TIM, IEC lib. *) or Modbus CP • safety as an option with S7-400 F *) in preparation Components Configurations Engineering TC in Oil & Gas TC in Water Summary Optimized RTU components exactly tailoredaccording to the specific application

  6. SIMATIC PCS 7 TeleControlOperator Stations (OS) SIMATIC PCS 7 OS Clients Intro • Single user system • for smaller quantity structure • in case of less operators • Client-Server-Configuration • for larger quantity structure • in case of many operators • „Dual leg“ Operator Station • Connection to PCS 7-Controller and PCS 7 TeleControl-RTUs in parallel • for single user station • for server • by separated servers f. PCS 7 + TeleControl combination at the clients (PCS 7 Client) Single userOperator Station Components Configurations Engineering TeleControlOS-Server (redundant) TC in Oil & Gas TC in Water Summary TeleControl RTUs SIMATIC PCS 7 OS Clients Single userOperator Station PCS 7 + TeleControl(double channel) OS-Server Operator Station flexible adaptable acc. toquantity structure of the particular plant ! PCS 7Controller TeleControlRTUs

  7. SIMATIC PCS 7 TeleControlEngineering Station Intro • PCS 7 TeleControl OS Engineering • PCS 7 Engineering Software • PCS 7 TeleControl DBA Software • Library with TeleControl Faceplates + Symbols • PCS 7 TeleControl OS Engineering Upgrade • for expansion of an existing PCS 7 ES • PCS 7 TeleControl DBA Software • Library with TeleControl Faceplates + Symbols • Tools und Driver • PCS 7 TeleControl DBA Software • PCS 7 TeleControl SINAUT Driver • PCS 7 TeleControl Modbus Driver • TeleControl Function Block-Library • Basis-Library with Standard-Functions • PCS 7 conform operation via Symbols + Faceplates • Basis-Library expandable on project base Components Configurations Engineering TC in Oil & Gas TC in Water Summary Comfortable Engineering with one (!) system !

  8. SIMATIC PCS 7 TeleControlTeleControl-Communication – Overview Intro • Transmitting media • Public / private communication networks (dedicated lines, dial-up networks [analog, ISDN] , radio systems [GSM]) • TCP/IP-based connections (DSL, GPRS) • SINAUT ST7 • For SIMATIC RTUs – SIPLUS RIC, S7-300, S7-400 • Hardware- & software components for WAN • Variety & modularity by choosing and combining existing networks and transmission routes • Modbus • For integration of existing / 3rd party RTUs • Acc. Standard-Modbus • TCP/IP-based connections as well • Other protocols(in preparation) • IEC 870-5-101 (serial) or -104 (TCP(IP) • DNP V3 Components Configurations Engineering TC in Oil & Gas TC in Water Summary Modem MD2 GSM-Modem Flexible choice of the communication to RTUsaccording infrastructure or specific requirements

  9. SIMATIC PCS 7 TeleControl TeleControl-Communication – SINAUT ST7 Intro • TeleControl protocol SINAUT ST7 – benefits: • Dynamic response for slower transmission lines • Good time resolution for all data processing due totime-stamping locally in the RTUs • Time synchronization of Remote Terminal Units viaTeleControl-Server (incl. summer-/winter time) • Data buffering in outstations (RTUs) to avoid loss of important data in case of communication failure • Reduction of transmitted data volume due toevent-triggered transmission of process values • Automatic monitoring of all outstations (RTUs)(alarming in case of failure of a station / connection) • Programming / parameterization of the SIMATIC S7-RTUs (via existing TeleControl communication) • SINAUT communication module TIM (TeleControlInterface Modul) for SIMATIC S7-300 / S7-400 Components Configurations Engineering TC in Oil & Gas TC in Water Summary Powerful TeleControl communication for cost-effective integration of outstations (RTUs) TIM 4R GPRS-Router

  10. SIMATIC PCS 7 TeleControl TeleControl-Communication – Modbus Intro • Benefits of the Modbus interface • Integration of existing RTU infrastructure into aPCS 7 TeleControl solution • Cost effective direct integration of 3rd-party RTUsinto a PCS 7 TeleControl Server • Widespread standard (also in TCP/IP) • also available for Siemens RTUs • Implementation of the Modbus communication • Connecting of RTUs via 3rd-party interface converter • Import of 3rd-party RTU data into Engineering (DBA) • Function block „Diagnostic Modbus RTU“ Components Configurations Engineering TC in Oil & Gas TC in Water Summary Effective integration of an existing RTU infra-structure into a PCS 7 TeleControl solution

  11. WAN WAN SIMATIC PCS 7 TeleControl„Single“ PCS 7 TeleControl - Configuration Intro Components Configurations Engineering TC in Oil & Gas TCP to serialconverter or SINAUT TIM 4RIE TCP/IPWAN Router TC in Water Summary TCP communication via div. media Modem (if necessary) Serial comm. via different media LocalRTUs

  12. WAN WAN SIMATIC PCS 7 TeleControl“Dual leg” Configuration with SIMATIC PCS 7 Intro Components Configurations Engineering TC in Oil & Gas Ethernet/TCP TCP to serialconverter or SINAUT TIM 4RIE TCP/IPWAN Router TC in Water PCS 7 AS Summary + TCP communication via div. media Modem (if necessary) Profibus I/O Serial comm. via different media LocalRTUs SIMATIC PCS 7 SIMATIC PCS 7 TeleControl

  13. WAN WAN SIMATIC PCS 7 TeleControlHigh available Configuration Intro SIMATIC PCS 7 OS Clients Components EngineeringStation Configurations Engineering TC in Oil & Gas TeleControlOS-Server (dedicated oderdouble channel) PCS 7OS-Server (redundant) TC in Water Summary ConverterTCP/IP  serialor centralSINAUT TIM PCS 7Controller AS 412FH AS 414FH AS 417FH PCS 7Controller AS 414 AS 416 AS 417 TCP/IPWAN Router Modem distributed TeleControloutstations withTCP/IP communication ET 200M ET 200M distributed TeleControloutstations ´withserial communication ET 200M ET 200M LocalRTUs Automation Stations based onSINAUT ST7 or SIPLUS RIC

  14. SIMATIC PCS 7 TeleControlEngineering Workflow - Overview Intro Components Configurations Create DBA Project Create PCS 7 Project Engineering TC in Oil & Gas TC in Water Summary Add processing information Create Hardware Structure Import RTU Data Structure tags in Plant View Compile / Download to OS Servers Start PCS 7 Operator Station

  15. SIMATIC PCS 7 TeleControlEngineering – DBA-Workflow and DBA-Type-Editor Intro • DBA-Workflow • Automatic generation of the OS database(display hierarchy, needed variables, alarms, alarm-messages and -prioritiesas well as function block symbols and faceplates) • Automatic placing of type specific function block symbols(e.g. for measuring monitoring) and automatic assignment with faceplate Components Configurations Engineering TC in Oil & Gas Manuel engineering basically is reduced to the design and positioning of thestatic graphical elements (e.g. pipes, tanks,...) TC in Water Summary • DBA-Type-Editor • Definition of new user specific function blocks (additional to basic lib.) • User function blocks  arrangement of information in variable structure  generation derivative values via VB scripts • Creation of user specific symbols and faceplates with PCS 7 standardtools (Graphics Designer and Faceplate Designer) • Same handling of the user function blocks as the standard blocks bythe DBA tool Flexible adaptation and extension of functionality acc. customer requirements

  16. SIMATIC PCS 7 TeleControlEngineering Workflow – DBA-Tool Intro Components Configurations Engineering TC in Oil & Gas PCS 7 Plant Hierarchy TC in Water Summary RTU objects assigned to the Plant Hierarchy List of RTU objects or data points RTU list

  17. SIMATIC PCS 7 TeleControlEngineering Workflow - Library Intro • TeleControl Function Block Library • Basic-Library with standard functions Counter, MeasuredValue, BitAlarm, SetPoint, Command, Valve, Motor, Pump, • Function blocks for diagnostic/control of communication TIM, SINAUT / Modbus RTU • Operation guidance conform to PCS 7 via Symbols,Faceplates as well as PCS 7 Alarming Hierarchy • Basic-Library expandable on project base via new function block types with appropriate script processing Components Configurations Engineering TC in Oil & Gas TC in Water Summary Homogeneous integration into the SIMATIC PCS 7Operator Station Same Look & Feel of local and remote processes avoidance of operation failures comprehensive overview about the whole plant

  18. SIMATIC PCS 7 TeleControlEngineering Workflow - Library Intro Components Configurations Engineering TC in Oil & Gas TC in Water Summary

  19. WAN WAN SIMATIC PCS 7 TeleControlEngineering Workflow – Access to local outstations SIMATIC PCS 7 OS Clients Intro • Access from Engineering Station • Programming of SINAUT ST7-outstations (RTUs) • Parameterization of SINAUT ST7-outstations (RTUs) • independent of transmission medium of the TeleControl connection EngineeringStation Components Configurations Engineering TeleControlOS-Server (redundant) TC in Oil & Gas TC in Water ConverterTCP/IP  serialor centralSINAUT TIM Summary TCP/IPWAN Router Modem TeleControl RTUs withTCP/IP communication TeleControl RTUs withserial communication Same communication connection forprogramming, parameterization andfor process control as well ! Savings in the infrastructure !

  20. SIMATIC PCS 7 TeleControl in Oil & GasTypical Applications Intro • Remote Terminal Units in Oil- & Gas • Metering stations in pipelines& gas networks • Valve stations in pipelines • Wellhead monitoring and automation incl. Emergency Shut Down (ESD)- Gas Well- Oil Well- Gas injection wells- Water injection wells Components Configurations Engineering TC in Oil & Gas TC in Water Summary These applications require integration of both local automation and distributed automation stations

  21. SIMATIC PCS 7 TeleControl in Oil & GasExample: Gas-Pipeline with Block Valve- and Metering-Stations Intro  Pipeline  Components PCS 7 Client PCS 7 Clients MeteringStations Configurations S7-400 Controller Eng.Station Engineering ca.100 I/O TC in Oil & Gas TC in Water PCS 7 Server(redundant) PCS 7 Server(redundant) SINAUT TIM local station Summary PCS 7 H/F Controller PCS 7H/F Controller TeleControl Server(redundant) RTU S7-300 incl. SINAUT TIM ca. 800 I/O ca. 300 I/O Profibus I/O Profibus I/O ca. 30 I/O SafetyESD SafetyESD Block Valve Stations CompressorStation Pressure ReducingStation  Pipeline 

  22. SIMATIC PCS 7 TeleControl in Oil & GasExample: Gas-Pipeline with Block Valve- and Metering-Stations • Uniform automation of all stations of the gas network • SIMATIC PCS 7 for Compressor- & Pressure Reducing-Station and PCS 7 TeleControl for Block Valve- & Measuring-Station • Consolidation in one (!) Operator Station (PCS 7 Client) • Uniform process control: same Faceplates, Alarming, Trends ... • High availability due to redundant configuration • PCS 7 OS-Server • TeleControl OS-Server • medium-redundant ring topology • Safety Integrated for ESD • Emergency-Shut-Down (ESD) fully integrated into automation solution (Compressor-/Pressure Red.-Stat.) Intro Components Configurations Engineering TC in Oil & Gas TC in Water Summary

  23. SIMATIC PCS 7 TeleControl in Oil & GasOperator Pictures  Pipeline / Block Valve / Scraper / Compressor / Intro Components Configurations Engineering TC in Oil & Gas TC in Water Summary

  24. SIMATIC PCS 7 TeleControl in Oil & GasOperator Picture  Overview Pipeline Intro Components Configurations Engineering TC in Oil & Gas TC in Water Summary

  25. SIMATIC PCS 7 TeleControl in Oil & GasOperator Picture  Line Block Valve Station Intro Components Configurations Engineering TC in Oil & Gas TC in Water Summary

  26. SIMATIC PCS 7 TeleControl in Oil & GasOperator Picture  Compressor Station Intro Components Configurations Engineering TC in Oil & Gas TC in Water Summary

  27. SIMATIC PCS 7 TeleControl in Oil & GasOperator Picture  Scraper Trap Station Intro Components Configurations Engineering TC in Oil & Gas TC in Water Summary

  28. SIMATIC PCS 7 TeleControl in Water & WastewaterTypical Applications • Remote Terminal Units inWater- & Waste Water • Valve stations in pipelines • Water well automation • Monitoring of Sewage basins • Control of pump stations Intro Components Configurations Engineering TC in Oil & Gas TC in Water Summary These applications require integration of both local automation and distributed automation stations

  29. SIMATIC PCS 7 TeleControl in Water & WastewaterExample: Sewage plant with Pump station / Rainwater Overflow Basin Intro Sewage treatment Plant Rainwater Components Overflow Basins Configurations ca. 25 I/O PCS 7 Client SIPLUS RIC Engineering TC in Oil & Gas local station TC in Water PCS 7 Server incl. TeleControl Server (redundant) Modem Summary Modem Modbus PCS 7 Controller PCS 7 Controller PCS 7 Controller local station Modem ca. 500 I/O ca. 500 I/O ca. 500 I/O Profibus DP Profibus DP Profibus DP S7-300 Profibus I/O Profibus I/O Profibus I/O ... ... ... ca. 150 I/O Inflow Pre-Treatment Aeration Blower Station Sludge Treatment Pumping Station

  30. SIMATIC PCS 7 TeleControl in Water & WastewaterExample: Sewage plant with Pump station / Rainwater Overflow Basin • Uniform control of the whole wastewater system • SIMATIC PCS 7 in Sewage Plant and PCS 7 TeleControl for Pump Station and Rain Spilling Basins • Consolidation in one (!) Operator Station (PCS 7 Server “dual leg”) • Uniform process control: same Faceplates, Alarming, Trends ... • Cost-effective application due to exactly tailored RTUs • S7-300 for Pump Station • SIPLUS RIC for Rain Spilling Basin(temp. range, energy consumption) • High security and availability of the communication • Use of private dedicated lines • Use of GPRS technology Intro Components Configurations Engineering TC in Oil & Gas TC in Water Summary Reports acc. ATV M260 standard are provided by Add-On product ACRON

  31. SIMATIC PCS 7 TeleControl in Water & WastewaterExample: Sewage plant with Pump station / Rain Spillway Basin Intro Components Configurations Engineering TC in Oil & Gas TC in Water Summary

  32. SIMATIC PCS 7 TeleControl in Water & WastewaterExample: Sewage plant with Pump station / Rain Overflow Basin Intro Components Configurations Engineering TC in Oil & Gas TC in Water Summary

  33. SIMATIC PCS 7 TeleControl in Water & WastewaterExample: Sewage plant – Blower Station Intro Components Configurations Engineering TC in Oil & Gas TC in Water Summary

  34. SIMATIC PCS 7 TeleControl in Water & WastewaterExample: Sewage plant - Pump station Intro Components Configurations Engineering TC in Oil & Gas TC in Water Summary

  35. SIMATIC PCS 7 TeleControl in Water & WastewaterExample: Sewage plant - Rainwater Overflow Basin Intro Components Configurations Engineering TC in Oil & Gas TC in Water Summary

  36. SIMATIC PCS 7 TeleControlSummary Intro • Higher Integration-level of the whole plant • Same hardware platform • Local time stamping in the RTUs • risk reduction of operation failures • Uniform user interface (same visualization and operation) • Less Engineering- & Maintenance effort • Uniform software platform • Minimum hardware requirements • Flexible selection of communication media(radio, WLAN, LAN, telephone, …) Components Configurations Engineering TC in Oil & Gas TC in Water Summary

  37. Thank you Title of the presentation Name: Roland H. Wieser Department: Industry Sector, SM MP7 Address: G.Braun-Str. 18 Karlsruhe Phone: 0721/595-4476 Mail: Roland.Wieser@siemens.com

More Related