Resistive Plate Chamber Activity At Helwan University Lab. Presented by Shereen Aly Helwan University Group (experimental and data analysis) Dr. Ayman Mahrous Dr.Ahmed Ali. Out lines:. What is RPC(Resistive plate chamber) Features of RPC Construction of RPC Helwan group activity for RPC.

loader
I am the owner, or an agent authorized to act on behalf of the owner, of the copyrighted work described.
capcha
Download Presentation

PowerPoint Slideshow about 'Resistive Plate Chamber Activity At Helwan University Lab' - aileen-ramirez


An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -
Presentation Transcript
resistive plate chamber activity at helwan university lab

Resistive Plate Chamber ActivityAt Helwan University Lab

Presented by

Shereen Aly

Helwan University Group

(experimental and data analysis)

Dr. Ayman Mahrous

Dr.Ahmed Ali

out lines
Out lines:
  • What is RPC(Resistive plate chamber)
  • Features of RPC
  • Construction of RPC
  • Helwan group activityfor RPC
what is rpc resistive pate chambers
What is RPC(Resistive Pate Chambers):
  • Resistive plate chambers (RPC) are fast gaseous detectors with high time resolution),which is an important part of the Muon system in CMS experiment.
features of rpc
Features of RPC
  • Resistive plate chambers are gaseous detectors which aim to provide a muon trigger in both the barrel and end cap regions.
  • High time resolution~1ns.
  • the robustness and simplicity of construction.
  • They are also well adapted to inexpensive industrial production.
helwan group activity for rpc1
Helwan group activity for RPC
  • In frame work of completing our mission which is studying and testing new equipments were received recently from CERN which mainly consists of :
  • Some electronic modules
  • Channel gas mixture
  • RPC
gap tests
Gap tests:
  • The leak test:

The Gap leak tests were performed by filling up the gaps Watching the pressure difference after 20 minutes, if the pressure change is less than 1% there’s no leak from the gap.

gap tests1
Gap tests

2-The spacer test: A transparent sheet having the layout of the spacer positions is kept aligned on the gap to be tested Pressure is applied at each spacer position and the change in the manometer reading is noted. Ideally there should be no change in the reading, for the gap to pass the test

gap tests2
Gap tests

3-The high voltage test:

  • Gaps which passed the leakage and spacer tests were placed under high voltage with the gas mixture (Freon 95% and Iso-butane5%) working with HV (9.4KV) if the current is less than 2 µA, the gap is ok.

High voltage cable

chamber tests
Chamber tests:
  • The Dark current(ramp current) test:

The detector draws some amount of current even in the absence of any charged particle passing through it. This current is known as dark current. To determine dark current of a chamber, the chamber is connected to high voltage. Currents through each of the gas gaps were monitored.

chamber tests1
Chamber tests:

2-Effeciency (TBD):

in order to start the efficiency test we constructed and tested scintillator detectors(from Saitama university) where the efficiency is the ratio of the number of cosmicraymuons detected by the chamber in coincidence with the- scintillator telescope to those detected by the telescope alone.

chamber tests2
Chamber tests

3-strip occupancy(TBD):

Strip response profiles are created to ensure all readout strips are active and working properly as they are supposed to.

4-Cluster size(TBD):

The Cluster size is defined as the number of contiguous hit strips of the same chambers and it should be low(the- average 2 strips).

conclusion
Conclusion:
  • The RPC is a gaseous detector with high efficiency.
  • We’re working on RPC tests to study its performance successfully.