An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Identification of Aging Aircraft Electrical Wiring Group Members: David Bryant Yuto Shinagawa Shaun Steinbarger Sponsors: Dr. R. O. Stearman Marcus Kruger BSS Engineering Inc.

  2. Overview • Background Information • Project Objectives • Experimental Setup • Problems Encountered • Laboratory Aging Results • Age Analysis Results • Recommendations • Conclusion

  3. Background Information • Navy and Air Force discover problem in the 1980s • Commercial aviation industry becomes concerned • Swiss Air 111 and TWA 800 • Substantial number of planes contain faulty wiring • Aircraft industry is seeking a method to discern age of aircraft wire

  4. Triboelectric Effect Definition: creation of charge imbalance due to contact separation resulting in unwanted interference

  5. Triboelectric Effect Solution to the problem: relate triboelectric effect to the age of a wire in hopes of identifying faulty wiring

  6. Project Objectives • Find standards in wire aging techniques • Design laboratory experiments • Successfully simulate wire aging • Monitor the triboelectric response of nominal and aged wires

  7. Distribution of Tasks Project Manager: Shaun Steinbarger Senior Engineer: David Bryant Senior Engineer: Yuto Shinagawa Wire Aging Chief Engineers: David Bryant Shaun Steinbarger 1. Logistics 2. Design 3. Implementation Age Analysis Chief Engineer: Yuto Shinagawa 1. Test Design 2. Test Implementation 3. Data Analysis

  8. Alpha Wire 1632 • Material – rubber • 20 Gage • 1.02 mm insulation thickness • 3.18 mm diameter • Single Conductor • Temperature Range • -30°C ~ 90°C • Cost • Twisted pair

  9. Laboratory Aging • CE Environmental Chambers • Heat Test • Humidity Test • Chemical Solution Test • Saltwater • Jet-A fuel with Prist additive • 15 specimens per test – 4 ft/specimen • Specimen removed every 3½ days

  10. Heat & Humidity Tests • Temperature – 120°F • Humidity – 70% • Temperature – 75°F

  11. Chemical Solution Test • Salt Water • Salinity – 8 fl. oz./gallon • Jet-A Fuel • Approved 5 gallon container • Ambient temperature - 100°F

  12. Signal Analyzer Amplifier Shaker WireCircuit Age Analysis I Data Acquisition System

  13. Data Acquisition System Amplifier Age Analysis II Signal Analyzer

  14. Age Analysis III Wire Circuit (closed) Electromagnetic Shaker

  15. Problems Encountered – Laboratory Aging • Heat Test • Desired Temperature 170°F • Heat Lamp • Testing terminated early

  16. Problems Encountered II – Age Analysis • Software Packages • Hewlett Packard 35660A • Ideas • LabView • HP3566A/67A • Three Separate Test Runs • Closed Loop Test • Electromagnetic Interference (EMF) • Inconsistent results

  17. Results I – Laboratory Aging • Humidity/Heat aging tests • No visual/physical results • Jet-A • Expanded in diameter and length • “Slippery” copper wire • Salt H2O • Corrosion of copper

  18. Results II- Age Analysis • No trends in data • Inconsistent • results

  19. Project Objectives • Find standards in wire aging techniques • Design laboratory experiments • Successfully simulate wire aging • Monitor the triboelectric response of nominal and aged wires • Success • Success • Success • Unsuccessful

  20. Recommendations I • Laboratory Aging • Reconfigure Heat Test • Locate an environmental chamber capable of 170°F • Expose wire to extreme cycles in temperature • Discontinue Humidity Test • Expose specimens to combinations of tests • Cycle procedure • 1 week Jet-A • 1 week Salt H2O • 1 week Heat

  21. Recommendations II • Age Analysis • Become proficient with Ideas • Eliminate all outside variables • Develop more consistent testing procedures

  22. Conclusions • Inconsistent results • Data does not provide any definitive trends between age and triboelectric response • Current experimental setup does not guarantee elimination of external disturbances • Change in scope of project • Find a relationship between the aged state • of a wire and its triboelectric response • Design and evaluate experimental procedures • so future groups may base their continuing • research upon them