1 / 47

Elamu, Kuldar Leis, Põlva

Tõnu Mauring tonu.mauring.001@ut.ee Tartu Ülikooli tehnoloogiainstituut. Elamu, Kuldar Leis, Põlva. 22. november 2012 Tallinn. Elamu, Kuldar Leis, Põlva. Elamu, Kuldar Leis, Põlva. Projekteerimise algus 2010. Suletud netopind: 338 m 2 Köetav pind: 307 m 2. Arhitektid: G. W. Reinberg

abner
Download Presentation

Elamu, Kuldar Leis, Põlva

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Tõnu Mauring tonu.mauring.001@ut.ee Tartu Ülikooli tehnoloogiainstituut Elamu, Kuldar Leis, Põlva 22. november 2012 Tallinn

  2. Elamu, Kuldar Leis, Põlva

  3. Elamu, Kuldar Leis, Põlva

  4. Projekteerimise algus 2010 Suletud netopind: 338 m2 Köetav pind: 307 m2

  5. Arhitektid: G. W. Reinberg M. Reinberg Projekti juhtimine: Sense OÜ Ehituse algus: sept 2011 Eeldatav lõpp: dets 2012

  6. A Hoone energiavajadus on väike kui väike? kWh/a kWh/a kWh/a • ruumide küte • soe vesi • elektriseadmed B See on suures osas kaetud taastuvenergiaga, mille maja on ise tootnud kui suures osas? kWh/a kWh/a kWh/a • ruumide küte • soe vesi • elektriseadmed

  7. null? A – B ≤ 0 (0 kWh/a)

  8. G.W.Reinberg G.W.Reinberg G. W. Reinberg

  9. G. W. Reinberg

  10. Tartu Innsbruck

  11. Välispiire Sein 400 mm tselluvill, 94 mm KLH massiivpuit, sisekrohv U = 0,105 W/(m2K) Katuslagi 500 mm soojustus, 102 mm KLH U = 0,079 W/(m2K) Keldrisein 500 mm EPS, 200 mm betoon U = 0,066 W/(m2K) Põrand pinnasel 300 mm XPS, 300 mm betoon, 100 mm EPS U = 0,086W/(m2K)

  12. Lõunafassaad PV 17,5 m2 vert. päikesekollektor ruumide kütte toetamiseks

  13. Katuse plaan 11,5 m2 päikese-kollektorid sooja tarbevee tootmiseks 92m2 PV paneelid 1x1,8m 235W 51 tk.

  14. elamu Kuldar Leis Põlva

  15. elamu Kuldar Leis Põlva

  16. elamu Kuldar Leis Põlva

  17. elamu Kuldar Leis Põlva

  18. elamu Kuldar Leis Põlva

  19. elamu Kuldar Leis Põlva

  20. elamu Kuldar Leis Põlva

  21. elamu Kuldar Leis Põlva

  22. elamu Kuldar Leis Põlva

  23. Külmasillavabad sõlmed Külmasilla lisakonduktanssΨ -0,046 W/(mK) välismõõtude järgi THERM 6.3 THERM 6.3 arvutus: PassiveHouse OÜ

  24. Külmasillavabad sõlmed Külmasilla lisakonduktanssΨ -0,014 W/(mK) välismõõtude järgi THERM 6.3 arvutus: PassiveHouse OÜ

  25. Aken SmartWin fixed U raam 0,57 W/(m2K) ψ spacer 0,026 W/(mK) ψ installation 0,010 W/(mK) SmartWin avanev U raam 0,77 W/(m2K) ψ spacer 0,026 W/(mK) ψ installation 0,010 W/(mK) U klaas 0,54 W/(m2K) g-väärtus 0,50

  26. Aken väljast soojustatud aknaraam, viimistletud fassaadi näide SmartWin fixed U raam 0,57 W/(m2K) ψ spacer 0,026 W/(mK) ψ installation 0,010 W/(mK) SmartWin avanev U raam 0,77 W/(m2K) ψ spacer 0,026 W/(mK) ψ installation 0,010 W/(mK) U klaas 0,54 W/(m2K) g-väärtus 0,50 Foto F. Freundorfer

  27. Aken THERM 6.3 väljast soojustatud aknaraam Ψ = 0,014 W/(mK) Ψ = 0,050 W/(mK) SmartWin võrdluseks soojustuseta paigaldus arvutus: PassiveHouse OÜ

  28. Aken THERM 6.3 Ψ = 0,014 W/(mK) Ψ = 0,050 W/(mK) SmartWin võrdluseks soojustuseta paigaldus arvutus: PassiveHouse OÜ

  29. THERM 6.3 SmartWin arvutus: PassiveHouse OÜ

  30. Soojustagastusega ventilatsioon Paul Novus 300 Soojustagastuse määr PHI meetodi järgi 93%

  31. Ruumide küttevajadus Bilanss EVS-EN ISO 13790:2008, PHPP

  32. Ruumide küttevajadus Bilanss EVS-EN ISO 13790:2008, PHPP

  33. Ruumide küttevajadus Bilanss EVS-EN ISO 13790:2008, PHPP

  34. Ruumide küttevajadus Bilanss EVS-EN ISO 13790:2008, PHPP kWh/a * utilisation factor heat gains 92%

  35. EVS-EN ISO 13790, PHPP

  36. Päikeseküttesüsteem: ruumide kütte tugi + soe tarbevesi 4910 kWh/a Kollektorid: Sonnenkraft SK IMK 11,5 m2 paigaldus 30° horisontaalist Sonnenkraft IFK 17,5 m2 vertikaalpaigaldus Akupaagid: 2 x 1000 l Comfort PS1000 Comfort Plus PSC 1000 bacup

  37. Kogu majapidamise elektrienergiatarve • soojuspump • majapidamiselekter • tehnosüsteem) 11 000 – 12 000 kWh/a PV paneelid 92m2 1x1,8m 235W 51 tk Arvutuslik tootlikkus: 11 100 kWh/a

  38. Seire energiavajadus, energia tootmine, konstruktsioonid

  39. SA Archimedes alammeede „Keskkonnatehnoloogia teadus- ja arendustegevuse toetamine“ “Hoonete keskkonnamõju vähendamine läbi energiatõhususe parandamise” Projekti nr: 3.2.0801.11-0035, periood: märts 2012- dets 2014 Tartu Ülikool / Tallinna Tehnikaülikool Seire: Tarindite temperatuuri, niiskuse ja soojavoo mõõtmine Päikese kiirguse mõõtmine  Hoone sisekliima mõõtmine Hoone tehnosüsteemide energiakasutuse, veekulu ja ventilatsiooni õhuvooluhulga mõõtmine

  40. Over the last 20 years, Passive House has become synonymous with quality, comfort and energy requirements low enough to be feasibly and sustainably covered with renewables. From 9 – 11 November 2012, owners and residents of Passive House buildings will be able to show members of the public just that by opening their homes and offices for the 9th annual International Passive House Days. http://www.passivehouse-international.org/index.php?page_id=262

  41. http://passivhausprojekte.de/projekte.php?lang=en&detail=2649http://passivhausprojekte.de/projekte.php?lang=en&detail=2649

  42. http://kanal2.ee/vaatasaateid/Kodusaade-1?videoid=6710

  43. Rohkem infot: www.sense.ee www.passiivmajaliit.ee

  44. Rohkem infot: http://www.flickr.com/photos/61283440@N05/6263456840/in/set-72157627814721214/lightbox/

  45. Rohkem infot: www.passiivmaja.ee 10-päevane täiendõpe www.passivhausplaner.eu

  46. Tänan tähelepanu eest! Tõnu Mauring tonu.mauring.001@ut.ee

More Related