The Viasensor G110-01N Multipurpose CO2 Analyzer (0-100%), O2 (0-100%), and gas temperature provides accurate readings in multiple applications,and is made for the usage in the food and brewing industries. Also used in medical, IVF-clinic, research and pharmaceutical settings, Viasensor.info is the leading supplier and servicer of Viasensor G110-11N Gas Analyzers and when it comes to CO2 & O2 Analyzer G110-11N is the market leader. If you consider co2 analyzer g110 viasensor has been developed to incorporate the latest technology and specification requirements, providing the user with a fast,

Viasensor
Download Presentation

EDITED_G110-Datasheet-1

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. G1 10 CO2 ANALYSER | SPECIALIST CONTROLLED ATMOSPHERE MONITORING CO2 analyser designed to monitor CO2 for multiple applications, including Brewing industry. This unit has been developed to incorporate the latest technology and specification requirements, that provide the user with a fast, simple to use analyser. FEATURES • CO2 0 - 100% • Options for: - O2 0 - 100% - Dual temperature probes 0 to 50°C - Data storage and download - Humidity Sensor 0 - 100% BENEFITS • Accurate CO2 readings Quick verification of CO2 levels Time saving with dual temperature probes • • • Large data storage and user friendly software and download • Easy to read large well lit display • Built in gas moisture removal SECTOR CO2 monitoring APPLICATIONS • Food Processing • Research • Brewing • Medical © Product designs and specifications are subject to change without notice. User is responsible for determining suitability of product. Diamond Scientific, LLC 625 Peachtree St., Cocoa, FL 32922 +1 321 223 7500 info@diamondsci.com www.diamondsci.com PAGE 1 OF 2 | DS3-ISSUE.09

  2. TECHNICAL SPECIFICATIONS POWER SUPPLY Battery type Li Ion Battery life 12 hours (10 hours with pump) Battery lifetime 600 cycles Battery charger 5v DC external power supply and internal charging circuit Charge time 4 hours Alternative power 5Vdc power supply GAS RANGES CO2 By custom dual wavelength infra-red cell with reference channel Gases measured O2 (optional) By internal electrochemical cell Oxygen cell lifetime Approximately 3 years in air 0 - 100% CO2 Range O2 0 - 100% CO2 ± 1% of range after calibration Measurement accuracy* O2 ± 1% of range after calibration CO2 ≤ 20 seconds Response time, T90 O2 ≤ 60 seconds *Plus accuracy of calibration gas used FACILITIES Temperature (optional) x2 using optional probes, range 0°C to +50°C Temperature accuracy ± 0.2°C Barometric pressure 800 - 1200 mbar RH measurement (optional) RH Probe 0 - 100% RH non condensing RH accuracy ± 1.5% RH across the range Visual and audible alarms User selectable CO2 and O2 alarm levels Communications USB type B mini-connector, HID device class Data storage 1000 reading sets + 270 events PUMP Flow 100cc / min typically ENVIRONMENTAL CONDITIONS Operating temperature 0°C to 50°C Relative humidity 0 - 95% non condensing Barometric pressure ± 500 mbar from calibration pressure IP rating IP40 PHYSICAL Weight 495 grams Size L: 165mm, W: 100mm, D: 55mm Case material ABS / Polypropylene with Silicone Rubber inserts Keys 17 Resin capped silicone rubber keys Liquid crystal display, 128 x 64 pixels Display With RGB LED back-light Built-in gas dryer tube to remove moisture Gas sample filters User replaceable PTFE water trap filter Note: Due to Geotech’s continuous programme of improvement, this specification is subject to change without prior notice CERTIFICATION Electromagnetic compatibility - Electrical apparatus for the detection and measurement of combustible gases, toxic gases or oxygen EN 50270 : 2006 Safety requirements for electrical equipment for measurement, control, and laboratory use. Part 1: General requirements EN 61010 -1 : 2010 © Product designs and specifications are subject to change without notice. User is responsible for determining suitability of product. QED Environmental Systems Ltd. Cyan Park - Unit 3, Jimmy Hill Way, Coventry, CV2 4QP, UNITED KINGDOM qedenv.com sales@qedenv.co.uk +1 321 223 7500 PAGE 2 OF 2 | DS3-ISSUE.09

More Related