Emergency Panel Lights-SeniorLED, China

SeniorLED is proud to add a brand new LED product to its vast catalog of LED panel lights, bulbs, and tubes. Our newest product is emergency LED panel light which promises emergency working time of over 120 minutes and comes with product warranty of 5 years. Check out the detail product document to learn about emergency LED panel light features and other details. send an email at info@seniorled.com to inquire about the product.

SeniorLED
Download Presentation

Emergency Panel Lights-SeniorLED, China

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. EMERGENCY LED PANEL LIGHT Charging TEST Malfunction Emergency Main Power Conforming to building codes normally means high installation costs. SeniorLED’s Panel Light comes with built-in backup power and the test switch built directly into the device, so there is no need to spend money installing walled switches. PREMIUM SERIES 4.0 E485145 Applications: Offices / Classrooms / Malls / Hotel / Lobbies / Back of house / Restaurants / Bus Stations / Medical Facility CRI > 80 Saving 80% 5 PF > 0.95 NO FLICKER DIMMABLE Battery Backup Light . 1 www.seniorled.com

  2. SPECIFICATION STANDARD SERIES Lumen Watt Emergency Time LED type N.W MODEL Size Main Emergency Main / Emergency 36W 40W SL-36W-66-28-TG-02 2*2 ft 3.90 kg/pc SMD 2835 192pcs SL-40W-66-28-TG-02 2*2 ft 3.90 kg/pc SMD 2835 192pcs 45W SL-45W-66-28-TG-02 SL-40W-123-28-TG-02 SL-50W-126-28-TG-05 2*2 ft 1*4 ft 2*4 ft 3.90 kg/pc SMD 2835 192pcs 110lm/W ≥120 mins 10W or 17W 40W 4.00 kg/pc SMD 2835 192pcs 7.40 kg/pc SMD 2835 336pcs 50W SL-60W-126-28-TG-05 2*4 ft 7.40 kg/pc SMD 2835 336pcs 60W STANDARD SERIES PREMIUM SERIES PREMIUM SERIES Lumen Watt Emergency Time MODEL LED type N.W Size Main Emergency Main / Emergency 25W 35W SL-25W-66-28-TG-01 10W 2*2 ft 3.90 kg/pc SMD 2835 192pcs SL-35W-66-28-TG-01 10W or 17W 2*2 ft 3.90 kg/pc SMD 2835 192pcs 130lm/W ≥120 mins 25W SL-25W-123-28-TG-01 SL-40W-126-28-TG-01 SL-50W-126-28-TG-01 10W 1*4 ft 2*4 ft 2*4 ft 4.00 kg/pc SMD 2835 192pcs 40W 7.40 kg/pc SMD 2835 384pcs 10W or 17W 7.40 kg/pc SMD 2835 384pcs 50W 2 www.seniorled.com

  3. SIGNAL INDICATOR g r a h C : d e L d e R E D n i a M P : r e w o G e r L n e E D u f l a M o i t c n : n o l l e Y w L E D D isplay status when working Charged O n i t a r e p g o i t i d n o C n Malfunction g i L t h Main Power g i L t h O N O N o l S a l F w / h s O F F O F F O N Emergency work O F F O N O F F O N g i L t h O F F O N / n i h t a e r B a l g m p o l S a l f w / h s O F F O F F O F F 1 W h t n e h e r e L d E a l f D a s e h s h t d n e r g e L n e E n i , s t i l D h t e t a c i d o s i t i t a c n g r a h . e 2 W h t n e h e r e L d E D o t n e w a t u h t d n e r g e L n e E . l l u f s i y t i c i r t c e l e t a h t e t a c i d n i , e h t a e r b D Non normal working state Charging TEST Malfunction Emergency Main Power STANDARD SERIES O n i t a r e p g o i t i d n o C n Charged Malfunction g i L t h Main Power PREMIUM SERIES O F F O F F O F F O F F No AC and Battery out O F F Fast Blink O F F O N No AC and Battery low -- -- Fast Blink -- Battery not Connected Power Fault -- -- O N O F F This product should be installed by trained electricians. Forbid connecting wires when power is on,make power on after make sure that there is no phenomenon of short circuit and the correction is ok. The wall switch only controls the main power, no function on emergency lighting. Green light-main power, Red light-charging, Yellow light-malfunction; Test: test button No indicator works in emergency status. Frequently test is prohibited. Each test interval is not less than one minute. 3 www.seniorled.com

  4. CHARGING/DISCHARGE Charging time < 24 hours 24 Hours 100% Emergency lighting time ≥ 120mins 120 Mins 100% 4 www.seniorled.com

  5. WIRE CONNECTION Connect the battery plug before wiring. Wire connection Dimmer Wire connection Dimmer LED Driver LED Driver GND ACL SW-L AC-N GND ACL SW-L NC AC-N DIM + DIM - 0-10V _ N L + L L N N GND GND 5 www.seniorled.com

  6. WIRE CONNECTION Connect the battery plug before wiring. Wire connection Dimmer Wire connection Dimmer LED Driver LED Driver GND ACL SW-L AC-N GND ACL SW-L NC AC-N DIM + DIM - 0-10V _ N L + L L N N GND GND 5 www.seniorled.com

  7. EMERGENCY DRIVER Rated input voltage(100-277V AC). Meets most safety standards for lighting. Main power built-in 3 in 1 dimming function(0-10V/10v PWM/1-100kΩ Resistance). Low ripple and noisy, Flicker Free. Main power output current can be regulated by potentionmeter. Main power protections : OCP/SCP/OVP. Built-in lithium battery as an emergency power supply energy. Emergency protections : OVP/LVP SCP/ TVP. Intelligent emergency automatic detection function. Emergency working time≥120 minutes. Product warranty: 5 years. 6 www.seniorled.com

  8. BATTERY The battery pack can be disassembled separately with easy replacement, preparing one or more sets as replacements to increase the service life of emergency backup panel. 300 cycles of standard CH and standard DC Emer gency power Max Emergency current Pack rating Voltage Battery capacity Emergency time Battery ≥ 120minute 4 pcs 300cycles 2000mA *4 10W 300 mA 14.4V ≥ 120minute 6 pcs 300cycles 2000mA *6 17W 500 mA 10.8V 7 www.seniorled.com

  9. PACKAGE hting Carton Size(mm) Quantity loaded by 20 GP container Quantity loaded by 40 GP container Quantity loaded by 40 HQ container Item N.W. Qty G.W. 2 x 2 FT 3.90 kg/pc 650x645x170 4pcs/CTN 19.6 kg/CTN 1620 3200 3700 2 x4 FT 7.40 kg/pct 1255x645x85 2pcs/CTN 18.8 kg/CTN 840 1630 1900 1 x4 FT 4.00 kg/pc 1250x345x170 4pcs/CTN 20 kg/CTN 1428 3000 3300 8 www.seniorled.com

  10. INSTALLATION Recessed into ceiling 1.Remove ceiling plaster slab 2. Connect power supply 3. Fix the panel light into right place 4.Stabilize the panel Suspending 1. A.Fix the anchor into target place on the ceiling. B.Fix the installation mount on the ceiling with plastic anchor. 2.Hang the panel to ceiling with Suspend installation kits 3. Adjust the length of steel wire.Connect the power supply x2 x4 2.Assembling 3 pieces aluminum profile together with screw. 1.Unpack box and take out aluminum profile A-2pcs, aluminum profile B-2pcs,as well as accessory pack 3.Fix semi-finished frame onto ceiling with screw(Concrete ceiling requires plastic anchor) surface mounted 4.slide panel into frame properly 8.Fix the last piece of aluminum profile with screw after panel is well placed. 9 . www.seniorled.com