  1. KaVo O-Drive KaVo O-drive OD30 removal of approximal enamel

  2. KaVo O-Drive KaVo O-drive OD30 KaVo O-drive Set consisting of: • KaVo O-drive OD30 instrument • OS-discs – oscillating segment discs

  3. KaVo O-Drive KaVo O-drive OD30 • Technical data KaVo O-drive OD 30: • reduction: 7,4 : 1 • movement: oscillating movement with 30° • Bur shaft: Multiple-Spline Shaft best for oscillating movement small tolerances – perfect control best fixing in the instrument

  4. KaVo O-Drive KaVo O-drive OD30 • Technical date segment discs: • (Komet, Brasseler: Patent DE 197 54 879) • OS = oscillating stripping • F = middle coating D54 • M = fine coating D 25 • 000 = special shaft • 140 = radius of discs (here 14 mm)

  5. KaVo O-Drive KaVo O-drive OD30 The use of KaVo OD 30 : • For removing of aproximal enamel ASR • To achieve free space for a correction of wrong or/and bad placed teeth • To achieve free space for insertion of implants • To avoid extensions on younger patients,if there is not enough space for the permanent teeth

  6. KaVo O-Drive KaVo O-drive OD30 • Clinical case – Prof. Joost-Brinkmann

  7. KaVo O-Drive KaVo O-drive OD30 • Clinical case – Prof. Joost-Brinkmann

  8. KaVo O-Drive KaVo O-drive OD30 • Clinical case – Prof. Joost-Brinkmann

  9. KaVo O-Drive KaVo O-drive OD30 • Clinical case – Prof. Joost-Brinkmann

  10. KaVo O-Drive KaVo O-drive OD30 • Clinical case – Prof. Joost-Brinkmann

  11. KaVo O-Drive KaVo O-drive OD30 • Advantages: • Faster and more precise as stripping with manual system • No harm of soft material through oscillating movement

  12. KaVo O-Drive KaVo O-drive OD30 • Movement system O-drive system • Radial movement through the complete working area • Reduction of enamel in one working step • No „stairs“ • No „canting“ • Fast working

  13. KaVo O-Drive KaVo O-drive OD30 • Use if the segment discs • Working data: 2.700 to 5.500 movements (osc/minute) • Segment discs is placed from occlusal and guided in one movement through the contact point . • Indication only to be done with efficient cooling(min. 50 ml/min.) • Afterwards a polishing is needed

  14. KaVo O-Drive KaVo O-drive OD30 competitors: • Fa. Intensiv with ORTHO-strips-system • Surface can not be done in one working step • Bad access in the molar area