audio and acoustic analyzer
Download
Skip this Video
Download Presentation
Audio and Acoustic Analyzer

Loading in 2 Seconds...

play fullscreen
1 / 51

Audio and Acoustic Analyzer - PowerPoint PPT Presentation


  • 203 Views
  • Uploaded on

Audio and Acoustic Analyzer. Introducing the new flagship of the handheld EXEL line. V1.001, Sep. 09. Audio and Acoustic Analyzer. Sound Level Meter Real Time Analyzer. Audio and Acoustic Analyzer. Sound Level Meter Real Time Analyzer Acoustic Analyzer. Audio and Acoustic Analyzer.

loader
I am the owner, or an agent authorized to act on behalf of the owner, of the copyrighted work described.
capcha
Download Presentation

PowerPoint Slideshow about 'Audio and Acoustic Analyzer' - Olivia


An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -
Presentation Transcript
audio and acoustic analyzer
Audio and Acoustic Analyzer

Introducing the new

flagship of the

handheld EXEL line.

V1.001, Sep. 09

audio and acoustic analyzer1
Audio and Acoustic Analyzer
  • Sound Level MeterReal Time Analyzer
audio and acoustic analyzer2
Audio and Acoustic Analyzer
  • Sound Level MeterReal Time Analyzer
  • Acoustic Analyzer
audio and acoustic analyzer3
Audio and Acoustic Analyzer
  • Sound Level MeterReal Time Analyzer
  • Acoustic Analyzer
  • STI-PA Analyzer
audio and acoustic analyzer4
Audio and Acoustic Analyzer
  • Sound Level MeterReal Time Analyzer
  • Acoustic Analyzer
  • STI-PA Analyzer
  • Audio Analyzer
applications
Applications
  • Live Sound Solutions
  • Sound Installations and Recording Studios
  • Broadcast
  • Environmental Noise Measurements
  • Service and Repair Centers
configurations
+

M2210

+

M4260

Configurations
  • Set XL2 + M2210XL2 with M2210 - Extended Performance - Measurement Microphone withclass 1 frequency response
  • Set XL2 + M4260XL2 with M4260 Measurement Microphone, Class 2
slide9
Big LCD 160x160
  • with Backlight
  • Function Buttons
slide10
Rotary Wheel
  • Limit LED with
  • red, yellow, green
  • Indication
slide11
Shock
  • Protection
  • Jacket
slide12
Headphone
  • Output
slide14
Battery Compartment
  • with Li-Po Battery
  • included
  • Rear Speaker
slide15
Balanced &
  • Unbalanced Input
  • Tripod Mount
slide16
Voice Note
  • Microphone
slide17
Mains Power
  • Adapter Input
  • USB Interface
  • Digital I/O
  • (prepared for later
  • firmware extension)
slide19
TOSLink Output
  • (prepared for later
  • firmware extension)
features
Features
  • Flexible User Interface
  • Visual Limit LED of high sound levels
  • Mini-SD Card, 2 GB removable
  • Real Time Clock
  • Built-in Speaker
  • Rechargeable Li-Po Battery included
  • Automated Sensor Detection reads electronic data sheet of M4260 and M2210
  • Wave File Recording*
  • Voice Notes*

*optional

sound level meter rta
Sound Level Meter / RTA
  • Applications
    • Live Sound Events
    • Environmental Noise Monitoring
sound level meter rta1
Sound Level Meter / RTA
  • Measures actual level, Leq, Lmin, Lmax, LCpeak, …
  • Frequency weightingA, C, Z
  • Time Weighting F, S, I*
  • Linearoperating range >100dB
  • XL2 accuracy acc. IEC 61672, class 1
  • Logs automatically to Mini-SD card
  • Real time clock

*optional

sound level meter rta2
Sound Level Meter / RTA

Extended Acoustic Pack

  • Percentiles %: 1, 5, 10, 50, 90, 95, 99%
  • Time Weighting: Impulse
  • Sound Pressure Level LIeq
  • Sound Exposure Level LAE
  • TaktMax as specified in DIN 45645-1
  • WAV-file recording (ADPCM)
  • Voice note recording
  • High-resolution FFT up to 0.3Hz steps
sound level meter rta3
Sound Level Meter / RTA
  • All measurement results are simultaneously available.
  • Select the available levels to be shown on the XL2 display
sound level meter rta4
Sound Level Meter / RTA
  • 3 or 5 levels may be displayed simultaneously in different selectable sizes
sound level meter rta5
Sound Level Meter / RTA
  • Displays two spectra simultaneously
  • Resolution selectable
  • Broadband values displayed in parallel
  • Measurement range selectable
  • Measurement time and control
sound level meter rta6
Sound Level Meter / RTA
  • Pre-defined limits for all levels
  • Firmware V1.00 operates with fixed limits
    • Level ok  Limit LED is GREEN
    • Level near limit  LED is YELLOW
    • Limit exceeded  LED is RED
live sound challenges
Live Sound Challenges

Stage

  • Sound pollution protection limits maximum level in audience area.
  • Loudest audience position is commonly not accessible for measurements.
  • XL2 offers a wizard to measure correction values k1 and k2 between loudest position and measurement point

Loudest accesible position

 Audience position

Measurement

Position

k1 = Difference in LAeq

k2 = Difference in LCPeak

FOH

Public listeningarea

correction factor wizard
Correction Factor Wizard
  • Run Pink Noise in the auditorium
  • Measure level at the loudest position
  • Measure level at the measurement point, e.g. at the mixing desk FOH
  • XL2 stores results with time stamp and displays the calculated correction values k1 and k2
audio analyzer
Audio Analyzer
  • Balanced XLR, unbalanced RCA input
  • -112 dBu to 30 dBu (1.4uV to 25V)
  • Residual THD+N <-100dB (0.001%)
  • Frequency range: 9 Hz to 20 kHz
  • Frequency accuracy: 0.003%
  • Loudspeaker and headset output for signal monitoring
fft analyzer
FFT Analyzer
  • Measures LZF and Leq simultaneously
  • Real time FFT in 3 ranges
    • 10 Hz - 220 Hzwith 1.5 Hz steps
    • 20 Hz - 1.7 kHzwith 15 Hz steps
    • 200 Hz - 20 kHzwith 150 Hz steps
  • High-resolution FFT including zoom mode up to 0.3 Hz stepswith Extended Acoustic Pack
rt60 analyzer
RT60 Analyzer
  • Measures 8 octave bands from 63 Hz – 8 kHz according to ISO3382 by Schroeder-method
  • Auto triggering
  • Auto averaging
  • Measurement error indication
  • Stimulus:
    • Gated pink noise
    • Impulse sound source
polarity testing
Polarity Testing
  • Checks polarity of speaker cabinets, individual drivers and line signals
  • Positive/Negative detection
  • Using internal microphone or input signal of XLR/RCA connector
polarity testing1
Polarity Testing
  • In-depth verification of the polarity - frequency relation for speaker cabinets or other multi-way-systems
  • Sample Screenshot left:The major part of the signal energy is measured in the mid-range frequency bands, thus the overall displayed polarity is NEGATIVE.
propagation delay
Propagation Delay
  • For accurate setup of delay line arrangements
  • Measures delay between electrical reference and acoustical signal
  • Relative measurements supported
  • Displays distance to speaker in meter or feet
sti pa analyzer
STI-PA Analyzer
  • Measures speech intelligibility of public announcement systems
  • Complies with IEC 60268-16 (2003) and NFPA 72
  • Displays STI and CIS results
  • Shows table of modulation indices and Leq’s
  • Supports ambient noise post processing

*optional

application profiles
Application Profiles
  • XL2 supports application profiles
  • Application profile may disable and hide any selections or measurement functions
  • Allows fixed operator interfaces for basic users
  • Firmware V1.0 offers a set of fixed application profiles
store and log results
Store and Log Results
  • Results stored as ASCII files
  • Storing all or subsets of measurements results
  • Adding a voice note to measurement*
  • Records the ADPCM compressed audio signal in parallel*

*optional

automated sensor detection
Automated Sensor Detection
  • Automatically detects microphone type
    • Reads sensitivity
    • Reads product data
    • Shows last calibration
  • ASD CableExtension cable tandem up to 20 m supported
powering concept
Powering Concept
  • Rechargeable Li-Po battery
    • included
    • typical battery lifetime > 5 hours
  • Dry cell batteries
    • type AA, 4 x 1.5 V
    • typical battery lifetime > 4 hours
  • Mains power supply 9 VDC
    • charges Li-Po battery in operation
measurement microphones1
Measurement Microphones
  • Omni-directional, pre-polarized condenser, free-field microphone
  • Build-in Pre-amplifier
  • Electronic Data Sheet installed
  • Phantom Power 48 VDC
  • High dynamic range
  • Wide frequency range
  • Low residual noise

M2210

M4260

accessories
Accessories
  • Ever-Ready pouch
    • Detachable front flap
    • Connectors accessible
    • Zipper
  • EXEL System Case
    • Compartments for XL2, MR-PRO, M4260 or M2210
    • Accessories, battery and adapter
accessories1
Accessories
  • Battery Charger
    • Includes spare battery
    • Connects to 100-230V AC
    • Intelligent charger controller
  • Spare Battery
    • rechargeable spare battery
    • Li-Po battery
accessories2
Accessories
  • ASD Cable
    • For extended connections of the measurement microphones M4260 or M2210
    • Maintaining the automated sensor detection
    • Length = 5 meter (16 feet)
  • External AC power supply
    • Suitable also for use with MR-PRO
    • Operates XL2 and chargers Li-Po battery in parallel
firmware options
Firmware Options
  • Extended Acoustic Pack
    • Percentiles: 1%, 5%, 10%, 50%, 90%, 95%, 99%
    • Time Weighting: Impulse
    • Sound Pressure Level LIeq, Sound Exposure Level LAE
    • TaktMax and values as specified in DIN 45645-1
    • WAV-file recording (ADPCM)
    • Voice note recording for individual measurements
    • High-resolution FFT including zoom mode up to 0.3 Hz steps at 10 Hz - 20 kHz
firmware options1
Firmware Options
  • STI-PA Option
    • Measures speech intelligibility of public announcement systems
    • Complies with IEC 60268-16 (2003) and NFPA 72
    • Displays STI and CIS results
ad