SB Packing Automatic Downpuller Power Unit. For Parts or Service Call: 970-867-6664 office 402-659-2451 cell 970-590-9235 cell. Air bleed valve no adjustments. Do not adjust factory set. Pump compensator adjustment with ball valve at outlet closed turn in to increase pressure.

loader
I am the owner, or an agent authorized to act on behalf of the owner, of the copyrighted work described.
capcha
Download Presentation

PowerPoint Slideshow about 'SB Packing Automatic Downpuller Power Unit' - Gabriel


An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -
Presentation Transcript
sb packing automatic downpuller power unit

SB Packing AutomaticDownpuller Power Unit

For Parts or Service Call:

970-867-6664 office

402-659-2451 cell

970-590-9235 cell

slide3

Air bleed valve no adjustments

Do not adjust factory set

Pump compensator adjustment with ball valve at outlet closed turn in to increase pressure

slide4

Pump relief valve. Relief adjustment must be set higher than Pump compensator

Pump outlet check prevent back flow from other pumps.

Relief to tank hose

Pump case drain

Pump volume control turn in to decrease flow. Pump is factory set for full displacement

Pump suction line. If pump is replaced change o-ring between flange and pump housing

slide5

Water out

Water in

Gasketed clean out cover

Water control valve adjust here for desired oil temperature

Site level gage. Fluid level should remain in upper 2/3rds of gage

Temperature sensor for water control valve

slide6

Circulation line to relief check valves

Circulation pump outlet to cooler

Water to oil heat exchanger

Circulation oil from cooler to filter and tank

Back to back 65 psi check valves give 150 psi relief function

Circulation pump electric motor

slide7

When element dirty remove 4 bolts and remove cover , then internal spring, then pull out and replace element.

Return filter gage. Color indicator/ When in yellow or red replace element. Only read for gage reading while machine is cycling

Return oil connection from system

slide8

Case drain return ports

Filler breather cap

Reservoir drain

Low level temperature switch

Clean out covers with drain