1 / 4

Pure Storage Certified FlashArray Implementation Specialist (FAIS) Dumps

Easily download the Pure Storage Certified FlashArray Implementation Specialist (FAIS) Dumps from Passcert to keep your study materials accessible anytime, anywhere. This PDF includes the latest and most accurate exam questions and answers verified by experts to help you prepare confidently and pass your exam on your first try.

Bennett11
Download Presentation

Pure Storage Certified FlashArray Implementation Specialist (FAIS) Dumps

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Download Valid FlashArray Implementation Specialist Dumps for Best Preparation FlashArray Implementation Specialist Exam : Title Pure Storage Certified FlashArray Implementation Specialist (FAIS) : https://www.passcert.com/FlashArray-Implementation-Specialist.html 1 / 4

  2. Download Valid FlashArray Implementation Specialist Dumps for Best Preparation 1.An Implementation Engineer is performing a capacity consolidation on an X50R3. Which command is needed for the engineer to determine whether the customer’s FlashArray supports SAS Flash Modules? A. puredrive list --total --type controller B. purehw list --type controller --all C. purehw list --type drive --all Answer: C Explanation: This command reports every installed drive module, identifying SAS Flash Modules if present, whereas the other commands do not enumerate individual drive types. 2.On a FlashArray//XR50R2/3 Fibre Channel (FC) array, what is the default type and placement of the PCIe FC card? A. 2-port in slot 0 B. 2-port in slot 2 C. 4-port in slot 0 Answer: B Explanation: On an X50R2/3 FC array, Pure ships each controller with a factory-installed dual-port 32 Gb Fibre Channel card in the PCIe slot numbered 2, providing out-of-the-box SAN connectivity. 3.A data pack has been installed and the puredrive list command shows the drives in “unadmitted” status. Which command should be used to complete the admission? A. puredrive add B. puredrive admit C. purearray drive admit Answer: B Explanation: The puredrive admit command is used to complete the admission process for drives showing as "unadmitted," integrating them fully into the FlashArray. 4.What is the redundancy of the FlashArray//XL PSUs? A. 1+1 B. 2+2 C. 3+1 Answer: B Explanation: FlashArray//XL power supply units (PSUs) are designed with 2+2 redundancy, meaning there are four PSUs where any two can fail without impacting array operation. 5.Which PCIe slot supports 4-port FC cards on FlashArray//XL? A. 2 B. 5 C. 8 2 / 4

  3. Download Valid FlashArray Implementation Specialist Dumps for Best Preparation Answer: C Explanation: On FlashArray//XL, the PCIe slot 8 supports installation of 4-port Fibre Channel cards, allowing higher port density for SAN connectivity. 6.A FlashArray//XR2/3 has an Ethernet mezzanine (EMEZZ), what are the interface names of the ports on the mezzanine? A. ETH6, ETH7, ETH8, and ETH9 B. ETH8, ETH9, ETH10, and ETH11 C. ETH10, ETH11, ETH12, and ETH13 Answer: B Explanation: The Ethernet mezzanine on FlashArray//XR2/3 is assigned interfaces starting at ETH8 through ETH11, reflecting the numbering scheme for additional Ethernet ports beyond the base interfaces. 7.What should an Implementation Engineer do when installing rails in a threaded-hole rack? A. Use the positioning studs B. Install the rails as is C. Make an adjustment to the rack Answer: A Explanation: Positioning studs are used to align and secure the rails correctly in a threaded-hole rack, ensuring proper installation and stability of the FlashArray. 8.Support requests a powercycle on a newly-installed FlashArray. What is the correct way to perform this action? A. Push the power button on each controller. B. Unplug the cable on each power supply. C. Run purearray reboot. Answer: C Explanation: The proper and safe method to power cycle a FlashArray is to run the purearray reboot command, which gracefully restarts the system without risking data integrity or hardware issues. 9.Before leaving the site after an install, who is required to provide completion sign-off? A. Account team B. Customer C. Support Answer: B Explanation: The customer’s completion sign-off is required to confirm that the installation meets their expectations and requirements before the engineer leaves the site. 10.Prior to running the puresetup newarray command, which command should an Installation Engineer 3 / 4

  4. Download Valid FlashArray Implementation Specialist Dumps for Best Preparation run on a new install of an //XR4 array? A. pureboot list B. cobalt_check.py C. purehw list Answer: B Explanation: Running cobalt_check.py on a new //XR4 array verifies hardware and system readiness before executing puresetup newarray, ensuring a smooth setup process. 11.A customer has a FlashArray X20R3 with 22/22 data packs in the chassis at 80% space usage and wishes to swap one of the data packs for a 45TB pack. What step needs to be taken to facilitate this consolidation? A. Send a DirectFlash Shelf without any additional capacity. B. Send a DirectFlash Shelf with a 63TB of temporary extra capacity. C. Reduce array space usage to allow for the evacuation of the 22TB packs. Answer: B Explanation: Adding a DirectFlash Shelf with sufficient temporary extra capacity (63TB) allows data to be evacuated from the smaller 22TB packs during the swap, enabling consolidation without reducing array usage beforehand. 12.An Implementation Engineer is onsite to install a new DFM data pack (DP) to CH0.BAY10-CH0.BAY19 of a FlashArray. After adding the drives to the chassis, which command should the Implementation Engineer run to verify if the new DP is in a wide write group? A. find_drive.py B. puredb list drives C. puredrive list --pack CH0.BAY10 Answer: C Explanation: The puredrive list --pack command shows detailed information about the specified data pack, including whether its drives are part of a wide write group. 4 / 4

More Related