An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. The Multi SeriesDL2-Multi SKIPPER Electronics AS Enebakkveien 150 0680 Oslo www.skipper.no Tlf. +47 23 30 22 70 Fax +47 23 30 22 71 sales@skipper.no support@skipper.no

  2. SKIPPER DL2-Multi • SOG and STW 2 Axis Doppler Speed Log • 9” Touch display. • JB70D2 Electronic unit • Convenient mounting • Plugable spring terminals (Wago) • DIN or screw wall mounting • NMEA over LAN (IEC61162-450) • NMEA normal • Web or Display setup • LAN, Pulse, Aux, Analog and NMEA interfaces • Main system software is now in the interconnection unit, 9” Display features in the display. SKIPPER Electronics AS Enebakkveien 150 0680 Oslo www.skipper.no Tlf. +47 23 30 22 70 Fax +47 23 30 22 71 sales@skipper.no support@skipper.no

  3. The DL2 Multi– JB70D2 interconnection unit • Totally new system consisting of: • 2 x LAN (100MB) • 4 x NMEA out • 24VDC and 110-230VAC • Screw or DIN mounting • 2 x NMEA in (for multi-repeater functions or quality control) • 2x Aux out (pulse, fitness alarm, power failure alarm, Speed limits) • Auxiliary in (alarm reset) • Relay output (Function/power failure alarm/Speed limit) • Pluggable spring connectors • SD Disk for logging and software upgrade • 2x USB www.skipper.no Tlf. +47 23 30 22 70 Fax +47 23 30 22 71 sales@skipper.no support@skipper.no

  4. The CU-M001 for DL2 • New 9” Touch display • Universal display for all product and repeater (to follow). • Pluggable connector Power 24V, 2 NMEA inputs, 2 CAN, 1 NMEA port • LAN connector IEC61162-450 LWE standard, and TCP/IP • Mounting for Panel, Desktop or Wall • On Screen and Web setup SKIPPER Electronics AS Enebakkveien 150 0680 Oslo www.skipper.no Tlf. +47 23 30 22 70 Fax +47 23 30 22 71 sales@skipper.no support@skipper.no

  5. The DL2SG-SA Sensor • 100mm Standard Sensor • 40m Orange cable 3 pair Power, TX,RX • 4 Acoustic beams at 555kHz, temp sensor and future tilt sensor • Measures SOG from <2m to 150m* • Measures STW in first 3m under vessel • With depth output for each beam and average • Accuracy 2% , with 1% option (Code activated) • 2 Design variants – Re-openable / Fully moulded SKIPPER Electronics AS Enebakkveien 150 0680 Oslo www.skipper.no Tlf. +47 23 30 22 70 Fax +47 23 30 22 71 sales@skipper.no support@skipper.no

  6. System Connection SKIPPER Electronics AS Enebakkveien 150 0680 Oslo www.skipper.no Tlf. +47 23 30 22 70 Fax +47 23 30 22 71 sales@skipper.no support@skipper.no

  7. Auxiliary Connection SKIPPER Electronics AS Enebakkveien 150 0680 Oslo www.skipper.no Tlf. +47 23 30 22 70 Fax +47 23 30 22 71 sales@skipper.no support@skipper.no

  8. System Connection POWER LAN Auxiliary and Alarm NMEA In and out SKIPPER Electronics AS Enebakkveien 150 0680 Oslo SENSOR www.skipper.no Tlf. +47 23 30 22 70 Fax +47 23 30 22 71 sales@skipper.no support@skipper.no

  9. SKIPPER Electronics AS Enebakkveien 150 0680 Oslo SENSOR www.skipper.no Tlf. +47 23 30 22 70 Fax +47 23 30 22 71 sales@skipper.no support@skipper.no

  10. Installation SETUP • The CU-M001 Graphic unit and JB70D2 talk using the LAN IEC61162-450 standard • Both units are set up with ‘unique’ IP and IDs connected to serial number. • These can be changed, but must be ‘paired’ • Alarm must also be paired, if needed • IO Should be set up as required • Default set up for Alarm and Pulse SKIPPER Electronics AS Enebakkveien 150 0680 Oslo www.skipper.no Tlf. +47 23 30 22 70 Fax +47 23 30 22 71 sales@skipper.no support@skipper.no

  11. SKIPPER Electronics AS Enebakkveien 150 0680 Oslo www.skipper.no Tlf. +47 23 30 22 70 Fax +47 23 30 22 71 sales@skipper.no support@skipper.no

  12. Installation Control unit SETUP • Set the system type • Setup the IP address and ID as required • Setup the Group • Pair the units (Primary remote ID) • IT is / will be possible to pair up to other systems as well SKIPPER Electronics AS Enebakkveien 150 0680 Oslo www.skipper.no Tlf. +47 23 30 22 70 Fax +47 23 30 22 71 sales@skipper.no support@skipper.no

  13. Installation JB70D2 unit SETUP • Setup the IP address and ID as required • Setup the Group • If you change these you will loose connection and must return to display to reset • These changes can also be performed via web page, using the service software to relink SKIPPER Electronics AS Enebakkveien 150 0680 Oslo www.skipper.no Tlf. +47 23 30 22 70 Fax +47 23 30 22 71 sales@skipper.no support@skipper.no

  14. Installation Communications • Set Required outputs of the NMEA com ports and LAN- bridge communication SKIPPER Electronics AS Enebakkveien 150 0680 Oslo www.skipper.no Tlf. +47 23 30 22 70 Fax +47 23 30 22 71 sales@skipper.no support@skipper.no

  15. Installation Communications • Set Required Auxiliary inputs and outputs SKIPPER Electronics AS Enebakkveien 150 0680 Oslo www.skipper.no Tlf. +47 23 30 22 70 Fax +47 23 30 22 71 sales@skipper.no support@skipper.no

  16. Installation Vessel SKIPPER Electronics AS Enebakkveien 150 0680 Oslo www.skipper.no Tlf. +47 23 30 22 70 Fax +47 23 30 22 71 sales@skipper.no support@skipper.no

  17. Alarms • System has 3 alarms: • Speed High (B) • Speed Low (B) • System failure (C) • These are handled as • On Screen – No beeper so add beeper to relay if required • Hardware alarms – relay output, Aux output, Aux input (alarm reset/acknowledge) • NMEA ALR/ACK A message is sent on alarm, acknowledge and end of alarm state • NMEA ALF/ACN/ARC messages are sent and requests for changing status SKIPPER Electronics AS Enebakkveien 150 0680 Oslo www.skipper.no Tlf. +47 23 30 22 70 Fax +47 23 30 22 71 sales@skipper.no support@skipper.no

  18. Calibration • 2 modes, 3rd to follow SKIPPER Electronics AS Enebakkveien 150 0680 Oslo www.skipper.no Tlf. +47 23 30 22 70 Fax +47 23 30 22 71 sales@skipper.no support@skipper.no

  19. User Screens and setup SKIPPER Electronics AS Enebakkveien 150 0680 Oslo www.skipper.no Tlf. +47 23 30 22 70 Fax +47 23 30 22 71 sales@skipper.no support@skipper.no

  20. User Screens setup SKIPPER Electronics AS Enebakkveien 150 0680 Oslo www.skipper.no Tlf. +47 23 30 22 70 Fax +47 23 30 22 71 sales@skipper.no support@skipper.no