html5-img
1 / 35

Lecture 4 Laplace Transforms and the Transfer Function

Lecture 4 Laplace Transforms and the Transfer Function. Advantages of Laplace Transforms. Standard notation in dynamics and control Converts mathematical operations into algebra Provides major insight by using block diagrams S traight-forward technique in control design

zoltin
Download Presentation

Lecture 4 Laplace Transforms and the Transfer Function

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Lecture 4Laplace Transforms and the Transfer Function

  2. Advantages of Laplace Transforms • Standard notation in dynamics and control • Converts mathematical operations into algebra • Provides major insight by using block diagrams • Straight-forward technique in control design >>> leads to frequency response (steady-state)

  3. Laplace Transforms Method to transform time scale (t) into a complex domain (s). Examples: Usually f(0) is set to 0, i.e., the error at time t= 0 is zero or steady state conditions exist.

  4. Other Transforms

  5. Laplace Transforms in Process Control Laplace transforms are used in process control for several types of studies: • To solve linear differential equations • To analyze linear control systems • To predict transient response for different inputs • To determine frequency response of a system

  6. Laplace Transforms in Process Control

  7. 28. Proportional Control Kcε(t)KcE(s) Integral Control E(s)/TIs Derivative Control TD sE(s)

  8. Some Examples

  9. The method can be used on any order of an ordinary differential equation, limited only by the factoring of the denominator polynomial (i.e., the characteristic equation). The procedure must be modified for equal roots and imaginary roots.

  10. Useful feature of this approach is that the denominator of the transfer function can be studied directly to determine its poles or roots A pole = the reciprocal of a time constant. A root provides information about the exponential exponent in the time domain For example: The denominator can be factored into (2s + 1)(s+1) to give: From the two factors, we know that τ1 = ½ and τ2 = 1. However should the function be changed to:

  11. This system must be unstable. It will have a transient response (to a step change) that includes the following terms: e½t and e-t Obviously the former term is unbounded as t increases. In analyzing the stability of a control system, the exponent of all exponentials must be negative in order for the system to reach a new steady-state value.

  12. Other Applications

  13. Other Applications

  14. The Impulse Forcing Function

  15. First Order System Y(s) = G(s) U(s) G(s) is called a system transfer function. It is an intrinsic property of the system independent of input changes.

  16. Second Order System

  17. Second Order System So there are three possible solutions which depend on the value of ζ ζ> 1 Overdamped ζ= 1 Critically damped ζ< 1 Underdamped

  18. Block Diagram Algebra and Notation Consider the Transfer Function G(s): composed of two first order subsystems G1(s) and G2(s): (a) Multiplicative rule (b) Additive rule

  19. Control and Error Ratios

  20. Positive Feedback Loop

  21. Measurement Block Lag

  22. Equivalent Systems Asystem with a measurement block can be replaced with an "equivalent" single block system by finding the overall system transfer function by developing equations for the new system so the control and error ratios are identical:

  23. Equivalent Systems

  24. Load Ratio

  25. Forcing Functions Once a dynamic model has been created, the next step is to study its response to input variable changes. In conducting these studies, one input is varied according to some specific function while the other variables are held constant. These disturbances are known as "forcing functions" since their role is to "force" a known change within the control system. There are four basic types of forcing functions: - step change (transient response) - ramp change (used to establish models for uncontrollable variables) - sine wave change (frequency response – steady-state response) - impulse change (used to determine residence time)

  26. Forcing Functions

  27. Response to an Impulse Function The system (or process) response to an impulse change depends on the degree of mixing in the process. If the model operates according to plug flow (first-in/first-out) then the output will be as follows: • Plug Flow would be typical of a large TD value relative to a short or zero Tp value • - Mixed Flow would be typical of a short or zero TD value relative to the Tpvalue Should the process operate as a fully-mixed system, then the output will be:

  28. Response to an Impulse Function In reality, the real response will lie somewhere between these two extremes. The time delay consists of a pure delay component and a distributed component. The response to an impulse change for a series of tanks is shown below. The variable "n" is the number of fully-mixed tanks. As the number increases, the overall response approaches plug-flow. tR = V/Q

  29. Adverse Flow Behavior

  30. First Order System Response to a Step Change

More Related