Assessment of U.S. Corps Aerators in the San Joaquin River for the Port of Stockton. September 2004 Jones & Stokes Russ Brown, Tom Trexler, Megan Robinson. Goals/Objectives. Determine the current level of performance of both aerators

Download Presentation

Assessment of U.S. Corps Aerators in the San Joaquin River for the Port of Stockton

An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -

Presentation Transcript


Assessment of U.S. Corps Aerators in the San Joaquin River for the Port of Stockton

September 2004

Jones & Stokes

Russ Brown, Tom Trexler, Megan Robinson


Goals/Objectives

  • Determine the current level of performance of both aerators

  • Estimate the oxygen loads from the aerators and the oxygen transfer efficiency

  • Compare aerator performance to release of oxygen gas from jets and different aerator device (Biox Hose)


View of Aerator Dock


Measurement Efforts

  • Measurements in Front of North Jets while Operating Both Aerators

  • Measurements in Front of South Jets while using Oxygen Gas


Measurements and Estimations

  • Measured Velocity and DO concentrations of upwelling and/or flow-away currents

  • Estimated flow-away or upwelling width and calculated flows

  • Estimated Oxygen Loads from upwelling or flow-away flows and DO pick-up (measured DO minus background DO)


Operation of Both Aerators


Operation of South Jets with Pure Oxygen Gas


Both Aerators

DO Pick-up of 0.78 mg/l (Back. DO = 3.2 mg/l)

Total Flow-away Flow of 90 cfs

Total Oxygen Supply Rate of 402 lbs/day (assuming 40 ft flow-away width)

South Jets with Oxygen

DO Pick-up of 2.19 mg/l (Back. DO = 2.9 mg/l)

Avg. Upwelling Flow of 191 cfs

Avg. Oxygen Supply Rate of 2270 lbs/day

Oxygen Transfer Efficiency of 45%